Comparison of Hyperpolarized 3He and 129Xe MR Imaging in Cystic Fibrosis Patients

被引:10
|
作者
Shammi, Ummul Afia [1 ]
D'Alessandro, Michelle Felicia [2 ]
Altes, Talissa [3 ]
Hersman, F. William [4 ]
Ruset, Iulian C. [5 ]
Mugler, John, III [6 ,7 ]
Meyer, Craig [6 ,7 ]
Mata, Jamie [6 ]
Qing, Kun [6 ]
Thomen, Robert [1 ,3 ]
机构
[1] Univ Missouri, Biomed Biol & Chem Engn, Columbia, MO 65211 USA
[2] Univ Missouri, Sch Med, Columbia, MO USA
[3] Univ Missouri, Sch Med, Radiol, Columbia, MO 65211 USA
[4] Univ New Hampshire, Phys, Durham, NH 03824 USA
[5] Xemed LLC, Durham, NH USA
[6] Univ Virginia, Sch Med, Radiol & Med Imaging, Charlottesville, VA 22908 USA
[7] Univ Virginia, Biomed Engn, Charlottesville, VA USA
关键词
Hyperpolarized MRI; Ventilation defect percentage; Cystic fibrosis; Lung defects; MRI scan; MAGNETIC-RESONANCE; HEALTHY-VOLUNTEERS; QUANTITATIVE-ANALYSIS; LUNG-DISEASE; CHILDREN; ASTHMA; TOLERABILITY; SAFETY;
D O I
10.1016/j.acra.2021.01.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this study, we compared hyperpolarized He-3 and Xe-129 images from patients with cystic fibrosis using two commonly applied magnetic resonance sequences, standard gradient echo (GRE) and balanced steady-state free precession (TrueFISP) to quantify regional similarities and differences in signal distribution and defect analysis. Materials and Methods: Ten patients (7M/3F) with cystic fibrosis underwent hyperpolarized gas MR imaging with both He-3 and Xe-129. Six had MRI with both GRE, and TrueFISP sequences and four patients had only GRE seuence but not TrueFISP. Ventilation defect percentages (VDPs) were calculated as lung voxels with <60% of the whole-lung hyperpolarized gas signal mean and was measured in all datasets. The voxel signal distributions of both Xe-129 and He-3 gases were visualized and compared using violin plots. VDPs of hyperpolarized He-3 and Xe-129 were compared in Bland-Altman plots; Pearson correlation coefficients were used to evaluate the relationships between inter-gas and inter-scan to assess the reproducibility. Results: A significant correlation was demonstrated between Xe-129 VDP and He-3 VDP for both GRE and TrueFISP sequences (rho = 0.78, rho<0.0004). The correlation between the GRE and TrueFISP VDP for He-3 was rho = 0.98 and was rho = 0.91 for Xe-129. Overall, Xe-129 (27.2 +/- 9.4) VDP was higher than He-3 (24.3 +/- 6.9) VDP on average on cystic fibrosis patients. Conclusion: In patients with cystic fibrosis, the selection of hyperpolarized Xe-129 or He-3 gas is most likely inconsequential when it comes to measure the overall lung function by VDP although Xe-129 may be more sensitive to starker lung defects, particularly when using a TrueFISP sequence.
引用
收藏
页码:S82 / S90
页数:9
相关论文
共 50 条
  • [31] Feasibility, tolerability and safety of pediatric hyperpolarized 129Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis
    Laura L. Walkup
    Robert P. Thomen
    Teckla G. Akinyi
    Erin Watters
    Kai Ruppert
    John P. Clancy
    Jason C. Woods
    Zackary I. Cleveland
    Pediatric Radiology, 2016, 46 : 1651 - 1662
  • [32] Hyperpolarised gas filling station for medical imaging using polarised 129Xe and 3He
    Lee, Wai Tung
    Zheng, Gang
    Talbot, Cavin L.
    Tong, Xin
    D'Adam, Tim
    Parnell, Steven R.
    de Veer, Michael
    Jenkin, Graham
    Polglase, Graeme R.
    Hooper, Stuart B.
    Thompson, Bruce R.
    Thien, Francis
    Egan, Gary F.
    MAGNETIC RESONANCE IMAGING, 2021, 79 : 112 - 120
  • [33] Feasibility, tolerability and safety of pediatric hyperpolarized 129Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis
    Walkup, Laura L.
    Thomen, Robert P.
    Akinyi, Teckla G.
    Watters, Erin
    Ruppert, Kai
    Clancy, John P.
    Woods, Jason C.
    Cleveland, Zackary I.
    PEDIATRIC RADIOLOGY, 2016, 46 (12) : 1651 - 1662
  • [34] Comparison of 3D UTE free-breathing lung MRI with hyperpolarized 129Xe MRI in pediatric cystic fibrosis
    Munidasa, Samal
    Zanette, Brandon
    Dumas, Marie-Pier
    Wee, Wallace
    Braganza, Sharon
    Li, Daniel
    Ratjen, Felix
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 775 - 787
  • [35] Comparison of 3D UTE free-breathing lung MRI with hyperpolarized 129Xe MRI in pediatric cystic fibrosis
    Munidasa, Samal
    Zanette, Brandon
    Dumas, Marie-Pier
    Wee, Wallace
    Braganza, Sharon
    Li, Daniel
    Ratjen, Felix
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [36] Comparison of 3He and 129Xe MRI for evaluation of lung microstructure and ventilation at 1.5 T
    Stewart, Neil
    Chan, Ho-Fung
    Hughes, Paul
    Collier, Guilhem
    Horn, Felix
    Norquay, Graham
    Parra-Robles, Juan
    Yates, Denise
    Collini, Paul
    Lawson, Rod
    Marshall, Helen
    Wild, Jim
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [37] A comparison of CT ventilation with 3He and 129Xe MRI for functional avoidance treatment planning
    Tahir, B.
    Hughes, P.
    Robinson, S.
    Marshall, H.
    Stewart, N.
    Biancardi, A.
    Chan, H. F.
    Collier, G.
    Hart, K.
    Swinscoe, J.
    Hatton, M.
    Wild, J.
    Ireland, R.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S96 - S97
  • [38] Comparison of Functional Free-Breathing Pulmonary 1H and Hyperpolarized 129Xe Magnetic Resonance Imaging in Pediatric Cystic Fibrosis
    Couch, Marcus J.
    Munidasa, Samal
    Rayment, Jonathan H.
    Voskrebenzev, Andreas
    Seethamraju, Ravi Teja
    Vogel-Claussen, Jens
    Ratjen, Felix
    Santyr, Giles
    ACADEMIC RADIOLOGY, 2021, 28 (08) : E209 - E218
  • [39] Brain Imaging Using Hyperpolarized 129Xe Magnetic Resonance Imaging
    Chahal, Simrun
    Prete, Braedan R. J.
    Wade, Alanna
    Hane, Francis T.
    Albert, Mitchell S.
    CHEMICAL AND BIOCHEMICAL APPROACHES FOR THE STUDY OF ANESTHETIC FUNCTION, PT B, 2018, 603 : 305 - 320
  • [40] Small Animal Imaging with Hyperpolarized 129Xe Magnetic Resonance
    Hirohiko Imai
    Atsuomi Kimura
    Hideaki Fujiwara
    Analytical Sciences, 2014, 30 : 157 - 166