Comparison of Hyperpolarized 3He and 129Xe MR Imaging in Cystic Fibrosis Patients

被引:10
|
作者
Shammi, Ummul Afia [1 ]
D'Alessandro, Michelle Felicia [2 ]
Altes, Talissa [3 ]
Hersman, F. William [4 ]
Ruset, Iulian C. [5 ]
Mugler, John, III [6 ,7 ]
Meyer, Craig [6 ,7 ]
Mata, Jamie [6 ]
Qing, Kun [6 ]
Thomen, Robert [1 ,3 ]
机构
[1] Univ Missouri, Biomed Biol & Chem Engn, Columbia, MO 65211 USA
[2] Univ Missouri, Sch Med, Columbia, MO USA
[3] Univ Missouri, Sch Med, Radiol, Columbia, MO 65211 USA
[4] Univ New Hampshire, Phys, Durham, NH 03824 USA
[5] Xemed LLC, Durham, NH USA
[6] Univ Virginia, Sch Med, Radiol & Med Imaging, Charlottesville, VA 22908 USA
[7] Univ Virginia, Biomed Engn, Charlottesville, VA USA
关键词
Hyperpolarized MRI; Ventilation defect percentage; Cystic fibrosis; Lung defects; MRI scan; MAGNETIC-RESONANCE; HEALTHY-VOLUNTEERS; QUANTITATIVE-ANALYSIS; LUNG-DISEASE; CHILDREN; ASTHMA; TOLERABILITY; SAFETY;
D O I
10.1016/j.acra.2021.01.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this study, we compared hyperpolarized He-3 and Xe-129 images from patients with cystic fibrosis using two commonly applied magnetic resonance sequences, standard gradient echo (GRE) and balanced steady-state free precession (TrueFISP) to quantify regional similarities and differences in signal distribution and defect analysis. Materials and Methods: Ten patients (7M/3F) with cystic fibrosis underwent hyperpolarized gas MR imaging with both He-3 and Xe-129. Six had MRI with both GRE, and TrueFISP sequences and four patients had only GRE seuence but not TrueFISP. Ventilation defect percentages (VDPs) were calculated as lung voxels with <60% of the whole-lung hyperpolarized gas signal mean and was measured in all datasets. The voxel signal distributions of both Xe-129 and He-3 gases were visualized and compared using violin plots. VDPs of hyperpolarized He-3 and Xe-129 were compared in Bland-Altman plots; Pearson correlation coefficients were used to evaluate the relationships between inter-gas and inter-scan to assess the reproducibility. Results: A significant correlation was demonstrated between Xe-129 VDP and He-3 VDP for both GRE and TrueFISP sequences (rho = 0.78, rho<0.0004). The correlation between the GRE and TrueFISP VDP for He-3 was rho = 0.98 and was rho = 0.91 for Xe-129. Overall, Xe-129 (27.2 +/- 9.4) VDP was higher than He-3 (24.3 +/- 6.9) VDP on average on cystic fibrosis patients. Conclusion: In patients with cystic fibrosis, the selection of hyperpolarized Xe-129 or He-3 gas is most likely inconsequential when it comes to measure the overall lung function by VDP although Xe-129 may be more sensitive to starker lung defects, particularly when using a TrueFISP sequence.
引用
收藏
页码:S82 / S90
页数:9
相关论文
共 50 条
  • [21] Echo-planar MR imaging of dissolved hyperpolarized 129Xe -: Potential for MR angiography
    Månsson, S
    Johansson, E
    Svensson, J
    Olsson, LE
    Ståhlberg, F
    Petersson, JS
    Golman, K
    ACTA RADIOLOGICA, 2002, 43 (05) : 455 - 460
  • [22] MR imaging with hyperpolarized 3He gas
    Physics Department, Princeton University, P.O. Box 708, Princeton, NJ 08544-0708, United States
    MAGN. RESON. MED., 2 (271-275):
  • [23] Ventilation heterogeneity imaged by multibreath wash-ins of hyperpolarized 3He and 129Xe in healthy rabbits
    Hamedani, Hooman
    Kadlecek, Stephen
    Ruppert, Kai
    Xin, Yi
    Duncan, Ian
    Rizi, Rahim R.
    JOURNAL OF PHYSIOLOGY-LONDON, 2021, 599 (17): : 4197 - 4223
  • [24] Oxygen-dependent hyperpolarized 129Xe brain MR
    Li, Haidong
    Zhang, Zhiying
    Zhong, Jianping
    Ruan, Weiwei
    Han, Yeqing
    Sun, Xianping
    Ye, Chaohui
    Zhou, Xin
    NMR IN BIOMEDICINE, 2016, 29 (03) : 220 - 225
  • [25] Emphysema Index Based on Hyperpolarized 3He or 129Xe Diffusion MRI: Performance and Comparison with Quantitative CT and Pulmonary Function Tests
    Tafti, Sina
    Garrison, William J.
    Mugler, John P.
    Shim, Y. Michael
    Altes, Talissa A.
    Mata, Jaime F.
    de Lange, Eduard E.
    Cates, Gordon D.
    Ropp, Alan M.
    Wang, Chengbo
    Miller, G. Wilson
    RADIOLOGY, 2020, 297 (01) : 201 - 210
  • [26] Hyperpolarized 129Xe Time-of-Flight MR Imaging of Perfusion and Brain Function
    Shepelytskyi, Yurii
    Hane, Francis T.
    Grynko, Vira
    Li, Tao
    Hassan, Ayman
    Albert, Mitchell S.
    DIAGNOSTICS, 2020, 10 (09)
  • [27] Combining Hyperpolarized 129Xe MR Imaging and Spectroscopy to Estimate Pulmonary Vascular Resistance
    Costelle, A.
    Rajagopal, S.
    Mummy, D.
    Lu, J.
    Leewiwatwong, S.
    Driehuys, B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [28] Chronic Obstructive Pulmonary Disease: Lobar Analysis with Hyperpolarized 129Xe MR Imaging
    Matin, Tahreema N.
    Rahman, Najib
    Nickol, Annabel H.
    Chen, Mitchell
    Xu, Xiaojun
    Stewart, Neil J.
    Doel, Tom
    Grau, Vicente
    Wild, James M.
    Gleeson, Fergus V.
    RADIOLOGY, 2017, 282 (03) : 857 - 868
  • [29] CORRELATION OF LUNG CLEARANCE INDEX WITH HYPERPOLARIZED 129XE PULMONARY MRI IN PEDIATRIC CYSTIC FIBROSIS
    Rayment, J.
    Kanhere, N.
    Kowalik, K.
    Couch, M.
    Kavanagh, B.
    Ratjen, F.
    Santyr, G.
    PEDIATRIC PULMONOLOGY, 2016, 51 : 286 - 286
  • [30] Assessment of lung microstructure in ILD with 3He and 129Xe MRI
    Stewart, Neil J.
    Norquay, Graham
    Parra-Robles, Juan
    Marshall, Helen
    Leung, General
    Murphy, Philip S.
    Schulte, Rolf F.
    Elliot, Charlie A.
    Condliffe, Robin
    Billings, Catherine G.
    Smith, Ian
    Griffiths, Paul D.
    Wolber, Jan
    Whyte, Moira K.
    Kiely, David G.
    Wild, Jim M.
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46