On-line monitoring of partial discharges on stator windings of large rotating machines in the petrochemical environment

被引:7
|
作者
Bethge, A [1 ]
Lo, PKW
Phillipson, JT
Weidner, JR
机构
[1] Siemens AG, D-13629 Berlin, Germany
[2] Imperial Oil Ltd, Prod & Chem Div, Sarnia, ON N7T 7M5, Canada
[3] Exxon Chem Co, Southampton SO45 1TX, Hants, England
[4] Siemens AG, D-45466 Mulheim, Germany
关键词
machines; on-line monitoring; partial discharges;
D O I
10.1109/28.739022
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes a joint collaboration program between a major large machine manufacturer and a petrochemical manufacturer to investigate the effectiveness of time- and frequency-domain techniques for on-line monitoring of the health of high-voltage machine stator insulation systems. Information is given on the factory and site testing carried out, as well as on the analysis and discussion of the results. It is concluded that both techniques can be used in the petrochemical environment for general assessments, but the time-domain technique is required if identification of specific locations of discharge sites is needed.
引用
收藏
页码:1359 / 1365
页数:7
相关论文
共 50 条
  • [21] Dissipation Factor and Partial Discharge Measurements for the Quality Assessment of New Coils and Stator Windings of VPI Rotating Machines
    Contin, Alfredo
    Peruzzi, Gabriele
    [J]. 2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 455 - 458
  • [22] Monitoring partial discharges on 4 kV motor windings
    Tetrault, S
    Stone, GC
    Sedding, HG
    [J]. INDUSTRY APPLICATIONS SOCIETY 44TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 1997, : 159 - 165
  • [23] A New Method for On-Line Monitoring of Bushings and Partial Discharges of Power Transformers
    Koch, Maik
    Krueger, Michael
    [J]. PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 1205 - 1208
  • [24] Characteristics of on-line and off-line partial discharge on hydrogenerator stator windings using acoustic emission detection techniques
    Kaneko, T
    Ueda, T
    Takenouchi, O
    Otsubo, M
    Honda, C
    Tsuruta, Y
    Fukura, A
    Tanaka, K
    [J]. Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 837 - 840
  • [25] Effects of Acid Vapor and Water Vapor on Corona Partial Discharges of Stator Windings
    Li, Chuanyang
    Song, Jiancheng
    Lin, Lingyan
    Lei, Zhipeng
    Su, Wen
    [J]. 2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 1185 - 1188
  • [26] Effects of Vapor with Different Chemical Properties on Corona Partial Discharges of Stator Windings
    Li, Chuanyang
    Song, Jiancheng
    Lin, Lingyan
    Lei, Zhipeng
    Su, Wen
    Bi, Xiaoyu
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 964 - 972
  • [27] Sensitivity improvement of capacitive couplers for on-line partial discharge testing in rotating machines
    Zhu, H
    Green, V
    Sasic, M
    Haliburton, S
    [J]. IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 534 - 537
  • [28] Capacitive Slot Coupler for On-line Partial Discharge Monitoring of Stator Winding Insulation
    Kim, Yong Joo
    Kim, Geun Ju
    Kim, Jung Il
    Kim, Hee Dong
    Kong, Tae Sik
    [J]. 2014 ELECTRICAL INSULATION CONFERENCE (EIC), 2014, : 235 - 240
  • [29] Novel on-line partial discharge monitoring system for generator/motor stator insulations
    Kim, YJ
    Hwang, DH
    Park, DY
    Song, SO
    [J]. ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 330 - 334
  • [30] An on-line stator winding resistance estimation technique for temperature monitoring of line-connected induction machines
    Lee, SB
    Habetler, TG
    [J]. CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 1564 - 1571