Effects of Vapor with Different Chemical Properties on Corona Partial Discharges of Stator Windings

被引:11
|
作者
Li, Chuanyang [1 ]
Song, Jiancheng [1 ]
Lin, Lingyan [1 ]
Lei, Zhipeng [1 ]
Su, Wen [1 ]
Bi, Xiaoyu [1 ]
机构
[1] Taiyuan Univ Technol, Shanxi Key Lab Coal Min Equipment & Safety Contro, Taiyuan 030024, Peoples R China
关键词
Corona; humidity; online monitoring; partial discharges; stator windings; HUMIDITY; TEMPERATURE; EMISSION; AIR;
D O I
10.1109/TDEI.2014.6832238
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effects of vapor with different chemical properties on corona partial discharges (PDs) at the junction section of the semi-conductive tape and the stress grading tape of stator windings were investigated. The phase resolved partial discharge (PRPD) patterns were collected during the experiment to obtain the characteristics of the PDs. The result has confirmed that relative humidity (RH) of the vapor with different chemical properties can cause corona discharge to change significantly. The acidic vapor can suppress corona discharge effectively. When RH exceeds 60%, the corona discharge would be hardly induced even though the voltage is boosted up to twice the operating voltage. When RH is over 80%, corona discharge will develop into phenomenon of creeping on the surface of the ground wall insulation and can hardly be collected through the capacitive coupler.
引用
收藏
页码:964 / 972
页数:9
相关论文
共 50 条
  • [1] Effects of Acid Vapor and Water Vapor on Corona Partial Discharges of Stator Windings
    Li, Chuanyang
    Song, Jiancheng
    Lin, Lingyan
    Lei, Zhipeng
    Su, Wen
    [J]. 2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 1185 - 1188
  • [2] Analysis of partial discharges in stator windings
    Patsch, R
    Benzerouk, D
    [J]. 2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 641 - 644
  • [3] Influence of mechanical vibration on the behavior of partial discharges in generator stator windings
    Wu, K
    Kanegami, M
    Takahashi, T
    Suzuki, H
    Ito, T
    Okamoto, T
    Yano, H
    [J]. Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 281 - 284
  • [4] Travelling wave propagation of partial discharges along generator stator windings
    Su, Q
    Chang, C
    Tychsen, RC
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 1132 - 1135
  • [5] On line monitoring of partial discharges on stator windings of large rotating machines in the petrochemical environment
    Bethge, A
    Lo, PK
    Phillipson, JT
    Weidner, JR
    [J]. INDUSTRY APPLICATIONS SOCIETY 44TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 1997, : 267 - 273
  • [6] Effects of Frequency and Temperature on Partial Discharge Characterization of Stator Windings
    Kantar, Emre
    Eberg, Espen
    Hvidsten, Sverre
    [J]. 2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 369 - 373
  • [7] Reduction Techniques of Partial Discharge, Dissipation Factor, and External Corona for High Voltage Stator Windings
    Emery, F. T.
    [J]. 2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 315 - 327
  • [8] On-line monitoring of partial discharges on stator windings of large rotating machines in the petrochemical environment
    Bethge, A
    Lo, PKW
    Phillipson, JT
    Weidner, JR
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (06) : 1359 - 1365
  • [9] Partial discharge, dissipation factor, and corona aspects for high voltage electric generator stator bars and windings
    Emery, FT
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 347 - 361
  • [10] Partial discharges on low voltage stator windings subjected to voltage surges from IFDs - A look at conditions where partial discharges (PD) may occur
    Fenger, M
    Stone, GC
    Campbell, SR
    [J]. PULP & PAPER-CANADA, 2003, 104 (02) : 24 - 27