Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens

被引:125
|
作者
Alio, Jorge L. [1 ,2 ]
Pinero, David P. [3 ]
Plaza-Puche, Ana B.
Joanna Rodriguez, Maria
机构
[1] Vissum Corp, Inst Oftalmol Alicante, Res Dev & Innovat, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Univ Alicante, Dept Opt, E-03080 Alicante, Spain
来源
关键词
HIGHER-ORDER ABERRATIONS; WAVE-FRONT ANALYSIS; CONTRAST SENSITIVITY; CATARACT-SURGERY; RETINAL STRAYLIGHT; CLINICAL-OUTCOMES; IMAGE QUALITY; IMPLANTATION; RESTOR; DISTANCE;
D O I
10.1016/j.jcrs.2010.08.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual acuity outcomes and ocular and intraocular optical quality in patients with a monofocal intraocular lens (IOL) or a multifocal IOL with rotational asymmetry. SETTING: Vissum Corporation, Alicante, Spain. DESIGN: Comparative case series. METHODS: Consecutive eyes of cataract patients were divided into 2 groups. One group received a Lentis Mplus LS-312 multifocal IOL and the other, an Acri.Smart 48S monofocal IOL. Distance and near visual acuities, contrast sensitivity, intraocular aberrations (global minus corneal aberrations), and defocus curves were evaluated preoperatively and postoperatively during a 3-month follow-up. RESULTS: The study evaluated 52 eyes of 29 patients (age range 36 to 87 years); 24 eyes were in multifocal IOL group and 28 eyes, in the monofocal IOL group. Both groups had a significant improvement in uncorrected and corrected distance visual acuities and in distance-corrected near visual acuity (DCNVA) postoperatively (P <=.04). The multifocal IOL group had significantly better uncorrected near acuity and DCNVA (Jaeger [J] 5 versus J2) (both P<.01). The defocus curves showed significantly better visual acuities in the multifocal group at several levels of defocus. The multifocal group had significantly higher amounts of postoperative intraocular primary coma (P<.01), especially in eyes with significant IOL tilt, although there were no significant differences in contrast sensitivity between the 2 IOL groups (P >=.25). CONCLUSIONS: The new-generation multifocal IOL restored distance, intermediate, and near visual function after cataract surgery. The optical quality with this type of IOL was particularly affected by IOL lilt and decentration.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 50 条
  • [31] Multifocal intraocular lens exchange to monofocal for the management of neuroadaptation failure
    Olena Al-Shymali
    Jorge L. Alió del Barrio
    Colm McAlinden
    Mario Canto
    Laura Primavera
    Jorge L. Alio
    Eye and Vision, 9
  • [32] Multifocal intraocular lens exchange to monofocal for the management of neuroadaptation failure
    Al-Shymali, Olena
    Alio del Barrio, Jorge L.
    McAlinden, Colm
    Canto, Mario
    Primavera, Laura
    Alio, Jorge L.
    EYE AND VISION, 2022, 9 (01)
  • [33] Ocular parameters associated with visual performance of enhanced monofocal intraocular lens
    Da Ran Kim
    Young Chae Yoon
    Woong-Joo Whang
    Ho Sik Hwang
    Kyung-Sun Na
    BMC Ophthalmology, 24
  • [34] Clinical outcomes of a new diffractive multifocal intraocular lens
    Baha Toygar
    Ozge Yabas Kiziloglu
    Okan Toygar
    Ali Murat Hacimustafaoglu
    International Journal of Ophthalmology, 2017, (12) : 1844 - 1850
  • [35] Clinical outcomes of a new diffractive multifocal intraocular lens
    Toygar, Baha
    Kiziloglu, Ozge Yabas
    Toygar, Okan
    Hacimustafaoglu, Ali Murat
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (12) : 1844 - 1850
  • [36] Dual intraocular lens implantation: Monofocal lens in the bag and additional diffractive multifocal lens in the sulcus
    Gerten, Georg
    Kermani, Omid
    Schmiedt, Karl
    Farvili, Elham
    Foerster, Andreas
    Oberheide, Uwe
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2136 - 2143
  • [37] Visual performance and patient satisfaction of multifocal contact lenses in eyes undergoing monofocal intraocular Lens implantation
    Kamiya, Kazutaka
    Fujimura, Fusako
    Ando, Wakako
    Iijima, Kei
    Shoji, Nobuyuki
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (03): : 218 - 221
  • [38] Visual Outcomes of Eyes Implanted With a Toric Multifocal Intraocular Lens
    Crema, Armando S.
    Walsh, Aileen
    Ventura, Bruna V.
    Santhiago, Marcony R.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (07) : 486 - 491
  • [39] Visual simulation of retinal images through a decentered monofocal and a refractive multifocal intraocular lens
    Negishi, K
    Ohnuma, K
    Ikeda, T
    Noda, T
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2005, 49 (04) : 281 - 286