Performance evaluation of a new small-volume coagulation monitor - The SmartCheck INR system

被引:4
|
作者
Gardiner, Chris [1 ]
Longair, Ian [1 ]
Hills, Jennifer [1 ]
Cohen, Hannah [1 ]
Mackie, Ian J. [2 ]
Machin, Samuel J. [1 ]
机构
[1] UCL Hosp, Dept Haematol, London W1T 4EU, England
[2] UCL, London, England
关键词
coagulation; anticoagulation; point of care; international normalized ratio;
D O I
10.1309/K87FWL7UA8H8ANHR
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The SmartCheck INR (Unipath, Bedford, England) is a point-of-care device for professional and patient self-monitoring of oral anticoagulant therapy. It measures the international normalized ratio (INR) and assesses test strip integrity, temperature, and sample quality. No significant differences were found in SmartCheck INR results from 3 different instruments or in 3 test-strip lots. Within run imprecision was 0.89% and 6.36% for low and high control samples, respectively (mean INR, 0.99 and 4.08, respectively). Comparability was assessed in 68 patients receiving warfarin by using PTHS Plus (Instrumentation Laboratory, Lexington, MA) and Innovin (Dade Behring, Marburg, Germany) thromboplastins. Good correlations were observed between the methods (r = 0.89 and r = 0.90, respectively) with no significant differences in means: SmartCheck INR, 2.82; Innovin, 2.75; PTHS Plus, 2.74. Clinical agreement with laboratory methods was 88% for Innovin and 97% for PTHS Plus. The SmartCheck INR was easy to use with no mechanical failures during the evaluation and a low test-strip failure rate of 4.7%. The SmartCheck INR provides accurate and reproducible results and is suitable for routine monitoring of oral anticoagulant therapy in the majority of patients.
引用
收藏
页码:500 / 504
页数:5
相关论文
共 50 条
  • [1] A SMALL-VOLUME TRITIUM MONITOR AND FILL SYSTEM
    GOBBY, PL
    SALAZAR, MA
    BUSH, H
    GURULE, VA
    FOREMAN, LR
    ABELL, GC
    GILL, JT
    ELLEFSON, RE
    SOWDERS, MH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (01): : 88 - 92
  • [2] Evaluation of small-volume tubes for venous and capillary PT (INR) samples
    Onelov, L.
    Basmaji, R.
    Svensson, A.
    Nilsson, M.
    Antovic, J. P.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2015, 37 (05) : 699 - 704
  • [3] Analytical performance of the new coagulation monitoring system INRatio™ for the determination of INR compared with the coagulation monitor Coaguchek® S and an established laboratory method
    Taborski, U
    Braun, SL
    Völler, H
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2004, 18 (02) : 103 - 107
  • [4] Analytical Performance of the New Coagulation Monitoring System INRatio™ for the Determination of INR Compared with the Coagulation Monitor Coaguchek® S and an Established Laboratory Method
    Uwe Taborski
    Siegmund L. Braun
    Heinz Völler
    Journal of Thrombosis and Thrombolysis, 2004, 18 : 103 - 107
  • [5] NEW DEVELOPMENTS OF THE IMPAX SMALL-VOLUME AUTOMATED CRYSTALLIZATION SYSTEM
    CHAYEN, NE
    STEWART, PDS
    BALDOCK, P
    ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1994, 50 : 456 - 458
  • [6] CLINICAL-EVALUATION OF A NEW, SMALL-VOLUME INFUSION SYSTEM IN SURGICAL INTENSIVE-CARE PATIENTS
    SWENSON, E
    ILLSLEY, SS
    RUSSO, J
    DRUG INTELLIGENCE & CLINICAL PHARMACY, 1982, 16 (06): : 482 - 482
  • [7] Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung Model
    Bomberg, Hagen
    Meiser, Franziska
    Daume, Philipp
    Bellgardt, Martin
    Volk, Thomas
    Sessler, Daniel I.
    Groesdonk, Heinrich V.
    Meiser, Andreas
    ANESTHESIA AND ANALGESIA, 2019, 129 (02): : 371 - 379
  • [8] Small-Volume Noncontact Assessment of Blood Coagulation Via Acoustic Tweezing Coagulometry
    Kasireddy, Nithya
    Cummins, Elizabeth M.
    Pham, Huy Q.
    Rafique, Amina
    Khismatullin, Damir B.
    BLOOD, 2021, 138
  • [9] Resonant Acoustic Tweezing Spectroscopy for Small-Volume Noncontact Assessment of Blood Coagulation
    Kasireddy, Nithya
    Orie, Jeremy C.
    Khismatullin, Damir
    BLOOD, 2018, 132
  • [10] Validation of a New Small-Volume Sodium Citrate Collection Tube for Coagulation Testing in Critically Ill Patients with Coagulopathy
    Adam, Elisabeth H.
    Zacharowski, Kai
    Hintereder, Gudrun
    Zierfuss, Frank
    Raimann, Florian
    Meybohm, Patrick
    CLINICAL LABORATORY, 2018, 64 (06) : 1083 - 1089