Frequency characteristics of non-contact ultrasonic motor with motion error correction

被引:20
|
作者
Isobe, Hirorni
Kyusojin, Akira
机构
[1] Nagano Coll Technol, Dept Engn Mech, Nagano 3818550, Japan
[2] Nagaoka Univ Technol, Dept Mech Engn, Niigata 9402188, Japan
关键词
ultrasonic motor; non-contact substance transportation; micro positioning; motion error correction;
D O I
10.1016/j.precisioneng.2007.02.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The purpose of this research is to achieve real time motion error correction of the rotor in a non-contact ultrasonic motor (non-contact USM). The rotor is installed in a cylindrical stator with a small gap and designed so that it has a resonant frequency of 22.2 kHz, the 8th flexural mode of vibration. The multi-layered piezoelectric actuators excite the flexural wave traveling in the circumference direction. The ultrasonic vibration produces a sound field that levitates the rotor, and the traveling wave induces a near-boundary streaming to rotate the rotor by viscous force. In this paper, we describe an experimental test of the performance of a non-contact USM. When the flexural vibration amplitude was 0.3 mu m, the rotational speed was 4 rpm. The rotational speed and starting torque was proportional to the vibration amplitude. The starting performance to attain rotational speed had a time constant of 2 s for several different amplitudes hence the rotational torque is independent of the rotational speed and the resistance force on the rotor is governed by viscosity. In addition, the non-contact USM has the capability of contact-free micro positioning of the rotor by controlling the deformation of the piezoelectric actuators. The PI controller was constructed to correct the detected motion error of the rotor in the radial direction. As a consequence, a motion error of 0.8 mu m for one rotor revolution was reduced to 0. 1 mu m. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [21] Non-Contact Ultrasonic Exploration of Ancient Paintings
    Takahashi, Victor
    Fortineau, Jerome
    Lematre, Michael
    Lethiecq, Marc
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [22] Ultrasonic Response of Polymers by Non-contact Transducers
    Petculescu, Petre
    Zagan, Remus
    Dimitrescu, Dan
    MATERIALE PLASTICE, 2008, 45 (03) : 246 - 250
  • [23] Non-contact ultrasonic inspection of railroad tracks
    di Scalea, FL
    Kenderian, S
    Green, RE
    BRIDGING THE CENTURIES WITH SAMPE'S MATERIALS AND PROCESSES TECHNOLOGY, VOL 45, BOOKS 1 AND 2, 2000, : 1762 - 1769
  • [24] Non-contact ultrasonic measurements in food materials
    Saggin, R
    Coupland, JN
    FOOD RESEARCH INTERNATIONAL, 2001, 34 (10) : 865 - 870
  • [25] Non-contact Ultrasonic Support of Minute Objects
    Takasaki, Masaya
    Terada, Daisuke
    Kato, Yasuhiro
    Ishino, Yuji
    Mizuno, Takeshi
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 1059 - 1065
  • [26] Non-contact Energy Transfer Based on Ultrasonic
    Zou, Yuwei
    Huang, Xueliang
    Bei, Yang
    ADVANCED DESIGN TECHNOLOGY, PTS 1-3, 2011, 308-310 : 1341 - 1344
  • [27] Non-contact ultrasonic inspection of railroad tracks
    di Scalea, Francesco Lanza
    Kenderian, Shant
    Green Jr., Robert E.
    International SAMPE Symposium and Exhibition (Proceedings), 2000, 45
  • [28] Non-contact ultrasonic characterization of ceramics and composites
    Bhardwaj, MC
    NONDESTRUCTIVE EVALUATION OF CERAMICS, 1998, 89 : 265 - 281
  • [29] Ultrasonic Cuisine: Proposal of Ultrasonic Non-contact Stirring Methods
    Sato, Yuta
    Abe, Kensuke
    Omomo, Kotaro
    Kawamura, Ryota
    Takazawa, Kazuki
    Ochiai, Yoichi
    UIST'17 ADJUNCT: ADJUNCT PUBLICATION OF THE 30TH ANNUAL ACM SYMPOSIUM ON USER INTERFACE SOFTWARE AND TECHNOLOGY, 2017, : 71 - 72
  • [30] Non-Contact Ultrasonic Defect Imaging in Composites
    Tenoudji, F. Cohen
    Citerne, J. M.
    Dutilleul, H.
    Busquet, D.
    42ND ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 6TH EUROPEAN-AMERICAN WORKSHOP ON RELIABILITY OF NDE, 2016, 1706