The Study of Plate-Screw Fixation in the Posterior Wall of Acetabulum Using Computed Tomography Images

被引:18
|
作者
Wu, Xiaobo [1 ]
Chen, Wei [1 ]
Zhang, Qi [1 ]
Su, Yanling [1 ]
Guo, Mingke [1 ]
Qin, Di [1 ]
Wang, Liqin [1 ]
Zhang, Yingze [1 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Orthopaed Surg, Shijiazhuang, Peoples R China
关键词
Posterior wall; Computed tomography; Screw penetration; Acetabular fracture; Internal fixation; INTRAOPERATIVE FLUOROSCOPY; FRACTURES; RECONSTRUCTION; REDUCTION; ACCURACY; ANTERIOR; SURGERY; ANATOMY;
D O I
10.1097/TA.0b013e3181ca05f6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The article aims to delineate the width of posterior column, the thickness of posterior wall, and safe angles for screw placement in the posterior wall to avoid intraarticular screw penetration. Methods: The computed tomography (CT) images of 32 cadaveric adult bony hemipelvic specimens were initially obtained for the purpose of the study. Each specimen was sectioned at 1-cm intervals, and each plane of the crosssection was perpendicular to the surface of posterior column. By analyzing the CT images postprocessed with multiplanar reconstruction, the width of posterior column, the thickness of posterior wall, and the modified safe angle for screw placement in the posterior wall were measured and recorded. To validate the data obtained from the cadaveric model, this method was applied on 30 adult volunteers. The corresponding data were recorded and compared with those acquired from the cadaveric bony hemipelvis. In efforts to approve the usefulness of this method in practice, we have performed screw insertions in another 10 acetabular specimens and two operative cases by using the data from analyzing the CT images. Results: The width of posterior column, the thickness of posterior wall, and the safe angles for screw insertion in the posterior wall were measured and recorded in both specimens and volunteers. Comparison of the corresponding data was made between specimens and volunteers, and no significant difference was found in the same gender and side (p > 0.05). The corresponding width of posterior column, thickness of posterior wall, and safe angles for screw placement was found to be statistically different between males and females in both specimens and volunteers (p < 0.05). In specimens group, the safe angles for the entry points 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm medial to the lateral acetabular brim were 49.23 degrees +/- 11.54 degrees, 42.48 degrees +/- 8.97 degrees, 29.53 degrees +/- 7.86 degrees, 23.68 degrees +/- 6.20 degrees, 18.42 degrees +/- 5.41 degrees and 15.91 degrees +/- 4.37 degrees in males and the corresponding angles for the entry points 0.5, 1.0, 1.5, 2.0, and 2.5 cm medial to the lateral acetabular brim were 45.02 degrees +/- 8.82 degrees, 35.98 degrees +/- 7.60 degrees, 23.77 degrees +/- 6.29 degrees, 19.96 degrees +/- 4.36 degrees, and 14.68 degrees +/- 3.48 degrees in females, respectively. CT images of 10 acetabular specimens and two cases with posterior wall fractures show all screws were inserted into the posterior wall without penetration into the joint space. Conclusions: The oblique multiplanar reconstruction images perpendicular to the surface of posterior column were selected to describe the safe angle for screw insertion into posterior wall, which can provide consistent results in both specimens and volunteers. The method can be applied in practice both on acetabular specimens and operative cases and is helpful to make individual perioperative planning for safer fixation of posterior wall fracture.
引用
收藏
页码:423 / 431
页数:9
相关论文
共 50 条
  • [1] Anatomic considerations of plate-screw fixation of the anterior column of the acetabulum
    Benedetti, JA
    Ebraheim, NA
    Xu, RM
    Yeasting, RA
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (04) : 264 - 272
  • [2] A Quantitative Anatomic Study of Plate-Screw Fixation of the Acetabular Posterior Column through a Posterior Approach
    Wang, Xianquan
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2022, 160 (01): : 49 - 55
  • [3] ANATOMIC CONSIDERATIONS FOR DORSAL SACRAL PLATE-SCREW FIXATION
    XU, RM
    EBRAHEIM, NA
    MOHAMED, A
    ELGAMAL, H
    YEASTING, RA
    JOURNAL OF SPINAL DISORDERS, 1995, 8 (05): : 352 - 356
  • [4] Effects of minimally invasive plate-screw internal fixation in the treatment of posterior pelvic ring fracture
    Li, Shiguang
    Meng, Xianxia
    Li, Wenlong
    Sun, Zhaoyun
    Wang, Xing
    Qi, Hongde
    Wei, Shuju
    Zhou, Dongsheng
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 16 (05) : 4150 - 4154
  • [5] The cervical spine and its relation to anterior plate-screw fixation: a quantitative study
    Sven R. Kantelhardt
    Joachim Oberle
    Sharam Derakhshani
    Erich Kast
    Neurosurgical Review, 2005, 28 : 308 - 312
  • [6] Computed Tomography as a Predictor of Hip Stability Status in Posterior Wall Fractures of the Acetabulum
    Moed, Berton R.
    Ajibade, David A.
    Israel, Heidi
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (01) : 7 - 15
  • [7] Stability Analysis of Plate-Screw Fixation for Femoral Midshaft Fractures
    Basirom, Izzawati
    Daud, Ruslizam
    Ijaz, Muhammad Farzik
    Rojan, Mohd Afendi
    Basaruddin, Khairul Salleh
    MATERIALS, 2023, 16 (17)
  • [8] INTRAMEDULLARY SUPRAMID PIN AND PLATE-SCREW FIXATION FOR FRACTURE OF HUMERUS
    NUMMI, P
    ACTA CHIRURGICA SCANDINAVICA, 1975, 141 (01): : 48 - 52
  • [9] The cervical spine and its relation to anterior plate-screw fixation: a quantitative study
    Kantelhardt, SR
    Oberle, J
    Derakhshani, S
    Kast, E
    NEUROSURGICAL REVIEW, 2005, 28 (04) : 308 - 312
  • [10] ANATOMIC CONSIDERATIONS FOR PLATE-SCREW FIXATION OF THE CERVICAL-SPINE
    AN, HS
    GORDIN, R
    RENNER, K
    SPINE, 1991, 16 (10) : S548 - S551