The Study of Plate-Screw Fixation in the Posterior Wall of Acetabulum Using Computed Tomography Images

被引:18
|
作者
Wu, Xiaobo [1 ]
Chen, Wei [1 ]
Zhang, Qi [1 ]
Su, Yanling [1 ]
Guo, Mingke [1 ]
Qin, Di [1 ]
Wang, Liqin [1 ]
Zhang, Yingze [1 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Orthopaed Surg, Shijiazhuang, Peoples R China
关键词
Posterior wall; Computed tomography; Screw penetration; Acetabular fracture; Internal fixation; INTRAOPERATIVE FLUOROSCOPY; FRACTURES; RECONSTRUCTION; REDUCTION; ACCURACY; ANTERIOR; SURGERY; ANATOMY;
D O I
10.1097/TA.0b013e3181ca05f6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The article aims to delineate the width of posterior column, the thickness of posterior wall, and safe angles for screw placement in the posterior wall to avoid intraarticular screw penetration. Methods: The computed tomography (CT) images of 32 cadaveric adult bony hemipelvic specimens were initially obtained for the purpose of the study. Each specimen was sectioned at 1-cm intervals, and each plane of the crosssection was perpendicular to the surface of posterior column. By analyzing the CT images postprocessed with multiplanar reconstruction, the width of posterior column, the thickness of posterior wall, and the modified safe angle for screw placement in the posterior wall were measured and recorded. To validate the data obtained from the cadaveric model, this method was applied on 30 adult volunteers. The corresponding data were recorded and compared with those acquired from the cadaveric bony hemipelvis. In efforts to approve the usefulness of this method in practice, we have performed screw insertions in another 10 acetabular specimens and two operative cases by using the data from analyzing the CT images. Results: The width of posterior column, the thickness of posterior wall, and the safe angles for screw insertion in the posterior wall were measured and recorded in both specimens and volunteers. Comparison of the corresponding data was made between specimens and volunteers, and no significant difference was found in the same gender and side (p > 0.05). The corresponding width of posterior column, thickness of posterior wall, and safe angles for screw placement was found to be statistically different between males and females in both specimens and volunteers (p < 0.05). In specimens group, the safe angles for the entry points 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm medial to the lateral acetabular brim were 49.23 degrees +/- 11.54 degrees, 42.48 degrees +/- 8.97 degrees, 29.53 degrees +/- 7.86 degrees, 23.68 degrees +/- 6.20 degrees, 18.42 degrees +/- 5.41 degrees and 15.91 degrees +/- 4.37 degrees in males and the corresponding angles for the entry points 0.5, 1.0, 1.5, 2.0, and 2.5 cm medial to the lateral acetabular brim were 45.02 degrees +/- 8.82 degrees, 35.98 degrees +/- 7.60 degrees, 23.77 degrees +/- 6.29 degrees, 19.96 degrees +/- 4.36 degrees, and 14.68 degrees +/- 3.48 degrees in females, respectively. CT images of 10 acetabular specimens and two cases with posterior wall fractures show all screws were inserted into the posterior wall without penetration into the joint space. Conclusions: The oblique multiplanar reconstruction images perpendicular to the surface of posterior column were selected to describe the safe angle for screw insertion into posterior wall, which can provide consistent results in both specimens and volunteers. The method can be applied in practice both on acetabular specimens and operative cases and is helpful to make individual perioperative planning for safer fixation of posterior wall fracture.
引用
收藏
页码:423 / 431
页数:9
相关论文
共 50 条
  • [21] Posterior wall fractures of the acetabulum: treatment using an anatomical plate through direct posterior approach
    Wenquan Xu
    Zhenhua Zhu
    Fuming Huang
    Qiguang Mai
    Shicai Fan
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3669 - 3675
  • [22] The "safe zone" for infrapectineal plate-screw fixation of quadrilateral plate fractures An anatomical study and retrospective clinical evaluation
    He, Li
    Sun, Yun
    Hou, Zhiyong
    Zhang, Qian
    Hu, Yinghua
    Bai, Xiangjun
    Yi, Chengla
    MEDICINE, 2019, 98 (19)
  • [23] Clinical and radiological outcomes of antegrade posterior column screw fixation of the acetabulum
    Cavalie, Guillaume
    Boudissa, Mehdi
    Kerschbaumer, Gael
    Seurat, Olivier
    Ruatti, Sebastien
    Tonetti, Jerome
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (04)
  • [24] A quantitative anatomic study of plate-screw fixation of the acetabular anterior column through an anterior approach
    Wang Xian-quan
    Cai Jin-fang
    Cao Xue-cheng
    Mu Wei-dong
    Zhang Wei
    Sun Shui
    Zhang Jin-lu
    Wang Jian
    Li Wei
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (02) : 257 - 262
  • [25] Precontoured buttress plate vs reconstruction plate for acetabulum posterior wall fractures: A biomechanical study
    Altun, Guray
    Saka, Gursel
    Demir, Teyfik
    Elibol, Fatma Kubra Erbay
    Polat, Mehmet Orcun
    WORLD JOURNAL OF ORTHOPEDICS, 2019, 10 (05): : 219 - 227
  • [26] Open reduction and internal fixation of posterior wall fractures of the acetabulum
    Moed, BR
    Carr, SEW
    Watson, JT
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (377) : 57 - 67
  • [27] Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
    Huang, Xiaowei
    Zhi, Zhongzheng
    Yu, Baoqing
    Chen, Fancheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [28] Computed Tomography-Based Feasibility Study of C1 Posterior Arch Crisscrossing Screw Fixation
    Sangondimath, Gururaj
    Mallepally, Abhinandan Reddy
    Salimath, Suman
    ASIAN SPINE JOURNAL, 2020, 14 (03) : 298 - 304
  • [29] Accuracy of detecting screw penetration of the acetabulum with intraoperative fluoroscopy and computed tomography
    Carmack, DB
    Moed, BR
    McCarroll, K
    Freccero, D
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (09): : 1370 - 1375
  • [30] Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
    Xiaowei Huang
    Zhongzheng Zhi
    Baoqing Yu
    Fancheng Chen
    Journal of Orthopaedic Surgery and Research, 10