The Study of Plate-Screw Fixation in the Posterior Wall of Acetabulum Using Computed Tomography Images

被引:18
|
作者
Wu, Xiaobo [1 ]
Chen, Wei [1 ]
Zhang, Qi [1 ]
Su, Yanling [1 ]
Guo, Mingke [1 ]
Qin, Di [1 ]
Wang, Liqin [1 ]
Zhang, Yingze [1 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Orthopaed Surg, Shijiazhuang, Peoples R China
关键词
Posterior wall; Computed tomography; Screw penetration; Acetabular fracture; Internal fixation; INTRAOPERATIVE FLUOROSCOPY; FRACTURES; RECONSTRUCTION; REDUCTION; ACCURACY; ANTERIOR; SURGERY; ANATOMY;
D O I
10.1097/TA.0b013e3181ca05f6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The article aims to delineate the width of posterior column, the thickness of posterior wall, and safe angles for screw placement in the posterior wall to avoid intraarticular screw penetration. Methods: The computed tomography (CT) images of 32 cadaveric adult bony hemipelvic specimens were initially obtained for the purpose of the study. Each specimen was sectioned at 1-cm intervals, and each plane of the crosssection was perpendicular to the surface of posterior column. By analyzing the CT images postprocessed with multiplanar reconstruction, the width of posterior column, the thickness of posterior wall, and the modified safe angle for screw placement in the posterior wall were measured and recorded. To validate the data obtained from the cadaveric model, this method was applied on 30 adult volunteers. The corresponding data were recorded and compared with those acquired from the cadaveric bony hemipelvis. In efforts to approve the usefulness of this method in practice, we have performed screw insertions in another 10 acetabular specimens and two operative cases by using the data from analyzing the CT images. Results: The width of posterior column, the thickness of posterior wall, and the safe angles for screw insertion in the posterior wall were measured and recorded in both specimens and volunteers. Comparison of the corresponding data was made between specimens and volunteers, and no significant difference was found in the same gender and side (p > 0.05). The corresponding width of posterior column, thickness of posterior wall, and safe angles for screw placement was found to be statistically different between males and females in both specimens and volunteers (p < 0.05). In specimens group, the safe angles for the entry points 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm medial to the lateral acetabular brim were 49.23 degrees +/- 11.54 degrees, 42.48 degrees +/- 8.97 degrees, 29.53 degrees +/- 7.86 degrees, 23.68 degrees +/- 6.20 degrees, 18.42 degrees +/- 5.41 degrees and 15.91 degrees +/- 4.37 degrees in males and the corresponding angles for the entry points 0.5, 1.0, 1.5, 2.0, and 2.5 cm medial to the lateral acetabular brim were 45.02 degrees +/- 8.82 degrees, 35.98 degrees +/- 7.60 degrees, 23.77 degrees +/- 6.29 degrees, 19.96 degrees +/- 4.36 degrees, and 14.68 degrees +/- 3.48 degrees in females, respectively. CT images of 10 acetabular specimens and two cases with posterior wall fractures show all screws were inserted into the posterior wall without penetration into the joint space. Conclusions: The oblique multiplanar reconstruction images perpendicular to the surface of posterior column were selected to describe the safe angle for screw insertion into posterior wall, which can provide consistent results in both specimens and volunteers. The method can be applied in practice both on acetabular specimens and operative cases and is helpful to make individual perioperative planning for safer fixation of posterior wall fracture.
引用
收藏
页码:423 / 431
页数:9
相关论文
共 50 条
  • [31] C-2 anterior plate-screw fixation: a quantitative anatomical and morphometric evaluation
    Senoglu, M.
    Ozbag, D.
    Gumusalan, Y.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2010, 111 (10): : 566 - 569
  • [32] COMMINUTED FRACTURES OF THE POSTERIOR WALL OF THE ACETABULUM - A BIOMECHANICAL EVALUATION OF FIXATION METHODS
    GOULET, JA
    ROULEAU, JP
    MASON, DJ
    GOLDSTEIN, SA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (10): : 1457 - 1463
  • [33] Fractures of the posterior wall of the acetabulum: Treatment using internal fixation of two parallel reconstruction plates
    Li, Heng
    Yang, Honghang
    Wang, Dan
    Xu, Yi
    Min, Jikang
    Xu, Xuchun
    Li, Zhanchun
    Yuan, Yongjian
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (04): : 709 - 714
  • [34] Radiological considerations of posterior cervical lateral mass fixation using plate and screw
    Yoon, SH
    Park, HC
    Park, HS
    Kim, EY
    Ha, Y
    Chong, CK
    Kim, SM
    Rim, DC
    YONSEI MEDICAL JOURNAL, 2004, 45 (03) : 406 - 412
  • [35] Fractures of the posterior wall of the acetabulum: Treatment using internal fixation of two parallel reconstruction plates
    Elhence, Abhay
    Jalan, Divesh
    Talreja, Harish
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (12): : 2112 - 2112
  • [36] The vertebral body depths of the cervical spine and its relation to anterior plate-screw fixation
    Ebraheim, NA
    Fow, J
    Xu, RM
    Yeasting, RA
    SPINE, 1998, 23 (21) : 2299 - 2302
  • [37] Treatment of pediatric femur supracondylar fractures: comparison of K-wire fixation versus plate-screw fixation
    Tekin, Sezgin Bahadir
    Karabulut, Cagri
    Bozgeyik, Bahri
    Gokcen, H. Bahadir
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2024, 33 (01): : 70 - 75
  • [38] Double column acetabular fractures fixation using a novel dynamic anterior plate-screw system: A biomechanical analysis
    Wu, Haiyang
    Song, Chengjing
    Shang, Ranran
    Shao, Qipeng
    Liu, Ximing
    Zhang, Hongqi
    Cai, Xianhua
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (03): : 407 - 413
  • [39] Comparative Study of W-Shaped Angular Plate and Reconstruction Plate in Treating Posterior Wall Fractures of the Acetabulum
    Zhang, Qi
    Chen, Wei
    Wu, Xiaobo
    Su, Yanling
    Hou, Zhiyong
    Zhang, Yingze
    PLOS ONE, 2014, 9 (03):
  • [40] A comparison of intramedullary nailing and plate-screw fixation in the treatment for ipsilateral fracture of the hip and femoral shaft
    Kesemenli C.C.
    Tosun B.
    Kim N.S.Y.