Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

被引:3
|
作者
Galea, C. A. [1 ]
Swanson, C. P. S. [2 ]
Cohen, S. A. [2 ]
Thomas, S. J. [1 ]
机构
[1] Princeton Fus Syst, Plainsboro, NJ 08536 USA
[2] Princeton Univ, Princeton Plasma Phys Lab, Princeton, NJ 08543 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2022年 / 93卷 / 09期
关键词
DETECTOR;
D O I
10.1063/5.0101712
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si3N4) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T-e) and density (n(e)). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of similar to 1 mu m thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n(e) similar to 10(9) cm(-3)) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. We describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements. Published under an exclusive license by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] LOW-ENERGY X-RAY MICRORADIOGRAPHY OF LASER FUSION TARGETS
    PREVENDER, TS
    LYNCH, AW
    MATERIALS EVALUATION, 1975, 33 (10) : 246 - 248
  • [42] SURFACE CHARACTERIZATION OF SOLIDS BY LOW-ENERGY X-RAY SPECTROMETRY
    ROMAND, M
    CHARBONNIER, M
    GAILLARD, F
    BADOR, R
    ROCHE, A
    THEVENARD, P
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1984, 9 (02): : 95 - 98
  • [43] ENTRANCE WINDOWS IN GERMANIUM LOW-ENERGY X-RAY DETECTORS
    LLACER, J
    HALLER, EE
    CORDI, RC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 53 - 60
  • [44] Low-energy plasma focus as a tailored X-ray source
    Zakaullah, M
    Alamgir, K
    Shafiq, M
    Sharif, M
    Waheed, A
    Murtaza, G
    JOURNAL OF FUSION ENERGY, 2000, 19 (02) : 143 - 157
  • [45] Low-Energy Plasma Focus as a Tailored X-Ray Source
    M. Zakaullah
    K. Alamgir
    M. Shafiq
    M. Sharif
    A. Waheed
    G. Murtaza
    Journal of Fusion Energy, 2000, 19 : 143 - 157
  • [46] LOW-ENERGY X-RAY MAP OF PUPPIS A SUPERNOVA REMNANT
    ZARNECKI, JC
    CULHANE, JL
    FABIAN, AC
    RAPLEY, CG
    SILK, R
    PARKINSON, JH
    POUNDS, KA
    NATURE-PHYSICAL SCIENCE, 1973, 243 (123): : 4 - 5
  • [47] A MULTIPLEX IMAGING SPECTROMETER FOR LOW-ENERGY X-RAY ASTRONOMY
    ROCCHIA, R
    ARNAUD, M
    BLONDEL, C
    CANTIN, M
    MOUGIN, B
    ROTHENFLUG, R
    TARRIUS, A
    ASTROPHYSICS AND SPACE SCIENCE, 1983, 96 (02) : 361 - 374
  • [48] CRYOGENIC DEVICE FOR A LOW-ENERGY X-RAY SPACE DETECTOR
    TESTARD, OA
    LENY, J
    LESZCZYSZYN, J
    JEHANNO, C
    CHERON, C
    ROTHENFLUG, R
    GRIFFITH, M
    CRYOGENICS, 1974, 14 (09) : 509 - 510
  • [49] Thin polycrystalline diamond for low-energy x-ray detection
    Conte, G
    Rossi, MC
    Salvatori, S
    Ascarelli, P
    Trucchi, D
    JOURNAL OF APPLIED PHYSICS, 2004, 96 (11) : 6415 - 6420
  • [50] PSEUDOWINDOW FOR USE PRODUCTION IN SOFT OF ULTRAHIGH VACUUM WITH VACUUM ULTRAVIOLET + SOFT X-RAY MONOCHROMATORS
    AXELROD, NN
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (07): : 918 - &