We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si3N4) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T-e) and density (n(e)). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of similar to 1 mu m thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n(e) similar to 10(9) cm(-3)) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. We describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements. Published under an exclusive license by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] X-ray lasers pumped by low-energy laser drivers
    Janulewicz, Karol A.
    Tuemmler, Johannes
    Priebe, Gerd
    Nickles, Peter V.
    LASERS AND APPLICATIONS, 2005, 5958
  • [32] Behaviour of transfer chambers in the low-energy x-ray range
    Boutillon, M
    METROLOGIA, 1996, 33 (05) : 479 - 484
  • [33] Experimental characterization of low-energy X-ray semiconductor detectors
    Lépy, MC
    Campbell, J
    Laborie, JM
    Plagnard, J
    Stemmler, P
    Teesdale, WJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 428 - 432
  • [34] ORIGIN OF LOW-ENERGY DIFFUSE COSMIC X-RAY FLUX
    CULHANE, JL
    FABIAN, AC
    NATURE, 1972, 237 (5355) : 379 - &
  • [35] PRIMEVAL GAS CLOUDS AND LOW-ENERGY X-RAY BACKGROUND
    KELLOGG, EM
    ASTROPHYSICAL JOURNAL, 1977, 218 (03): : 582 - &
  • [36] LOW-ENERGY X-RAY OBSERVATIONS OF THE WOLF 630 SYSTEM
    JOHNSON, HM
    ASTROPHYSICAL JOURNAL, 1987, 316 (01): : 458 - 461
  • [37] LOW-ENERGY X-RAY TRANSMISSION GRATING SPECTROMETER FOR AXAF
    BRINKMAN, AC
    VANROOIJEN, JJ
    BLEEKER, JAM
    DIJKSTRA, JH
    HEISE, J
    DEKORTE, PAJ
    MEWE, R
    PAERELS, F
    ASTROPHYSICAL LETTERS & COMMUNICATIONS, 1987, 26 (1-2) : 73 - 86
  • [38] GaAs low-energy X-ray radioluminescence nuclear battery
    Zhang, Zheng-Rong
    Liu, Yun-Peng
    Tang, Xiao-Bin
    Xu, Zhi-Heng
    Yuan, Zi-Cheng
    Chen, Wang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2018, 415 : 9 - 16
  • [39] Qualification and performance of the Low-Energy X-ray Reflectometer (LEXR)
    Henriksen, P. L.
    Christensen, F. E.
    Massahi, S.
    Ferreira, D. D. M.
    Svendsen, S.
    Gellert, N.
    Vu, L. M.
    Jegers, A. S.
    Shortt, B.
    SPACE TELESCOPES AND INSTRUMENTATION 2020: ULTRAVIOLET TO GAMMA RAY, 2021, 11444
  • [40] Low-energy X-ray spectral variability of NGC 4051
    Mon Not Royal Astron Soc, 3 (549):