Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

被引:3
|
作者
Galea, C. A. [1 ]
Swanson, C. P. S. [2 ]
Cohen, S. A. [2 ]
Thomas, S. J. [1 ]
机构
[1] Princeton Fus Syst, Plainsboro, NJ 08536 USA
[2] Princeton Univ, Princeton Plasma Phys Lab, Princeton, NJ 08543 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2022年 / 93卷 / 09期
关键词
DETECTOR;
D O I
10.1063/5.0101712
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si3N4) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T-e) and density (n(e)). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of similar to 1 mu m thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n(e) similar to 10(9) cm(-3)) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. We describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements. Published under an exclusive license by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] X-RAY MEASUREMENTS IN A LOW-ENERGY VACUUM SPARK
    SKOWRONEK, M
    ROMEAS, P
    LAROUR, J
    CHOI, P
    DENSE Z-PINCHES, 1989, 195 : 395 - 404
  • [2] LOW-ENERGY COSMIC X-RAY MEASUREMENTS
    BAXTER, AJ
    WILSON, BG
    GREEN, DW
    CANADIAN JOURNAL OF PHYSICS, 1969, 47 (23) : 2651 - &
  • [3] Low-energy X-ray detection with an in-vacuum PILATUS detector
    Marchal, Julien
    Luethi, Benjamin
    Ursachi, Catalin
    Mykhaylyk, Vitaliy
    Wagner, Armin
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [4] PHYSICAL ASPECTS OF USE OF LOW-ENERGY X-RAY IN MAMMOGRAPHY
    GARSOU, J
    JOURNAL BELGE DE RADIOLOGIE, 1972, 55 (01): : 5 - &
  • [5] A LOW-ENERGY X-RAY POLARIMETER
    RIEGLER, GR
    GARMIRE, G
    MOORE, W
    STEVENS, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (04): : 635 - &
  • [7] A synthetic diamond probe for low-energy X-ray dose measurements
    Assiamah, M.
    Nam, T. L.
    Keddy, R. J.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (05) : 545 - 552
  • [8] Pulse pileup statistics for energy discriminating photon counting x-ray detectors
    Wang, Adam S.
    Harrison, Daniel
    Lobastov, Vladimir
    Tkaczyk, J. Eric
    MEDICAL PHYSICS, 2011, 38 (07) : 4265 - 4275
  • [9] Measurements of Fano factors in silicon and germanium in the low-energy X-ray region
    Lowe, BG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3): : 354 - 364
  • [10] Measurements of Fano factors in silicon and germanium in the low-energy X-ray region
    Lowe, B.G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 399 (2-3): : 354 - 364