A New Brain Positron Emission Tomography Scanner With Semiconductor Detectors for Target Volume Delineation and Radiotherapy Treatment Planning in Patients With Nasopharyngeal Carcinoma

被引:7
|
作者
Katoh, Norio [1 ]
Yasuda, Koichi [1 ]
Shiga, Tohru [2 ,3 ]
Hasegawa, Masakazu [1 ]
Onimaru, Rikiya [1 ]
Shimizu, Shinichi [1 ]
Bengua, Gerard
Ishikawa, Masayori
Tamaki, Nagara [2 ,3 ]
Shirato, Hiroki [1 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Radiat Med, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ, Grad Sch Med, Dept Med Phys, Sapporo, Hokkaido 0608638, Japan
关键词
Nasopharyngeal carcinoma; Positron emission tomography; Radiotherapy planning; Semiconductor; Target volume delineation; STANDARD UPTAKE VALUE; CELL LUNG-CANCER; NECK-CANCER; TUMOR VOLUME; FDG-PET; HEAD; CT; FUSION; DEFINITION; SPECIMEN;
D O I
10.1016/j.ijrobp.2011.09.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We compared two treatment planning methods for stereotactic boost for treating nasopharyngeal carcinoma (NPC): the use of conventional whole-body bismuth germanate (BGO) scintillator positron emission tomography (PETCONVWB) versus the new brain (BR) PET system using semiconductor detectors (PETNEWBR). Methods and Materials: Twelve patients with NPC were enrolled in this study. [F-18]Fluorodeoxyglucose-PET images were acquired using both the PETNEWBR and the PETCONVWB system on the same day. Computed tomography (CT) and two PET data sets were transferred to a treatment planning system, and the PETCONVWB and PETNEWBR images were coregistered with the same set of CT images. Window width and level values for all PET images were fixed at 3000 and 300, respectively. The gross tumor volume (GTV) was visually delineated on PET images by using either PETCONVWB (GTV(CONV)) images or PETNEWBR (GTV(NEW)) images. Assuming a stereotactic radiotherapy boost of 7 ports, the prescribed dose delivered to 95% of the planning target volume (PTV) was set to 2000 cGy in 4 fractions. Results: The average absolute volume (+/- standard deviation [SD]) of GTV(NEW) was 15.7 ml (+/- 9.9) ml, and that of GTV(CONV) was 34.0 (+/- 20.5) ml. The average GTV(NEW) was significantly smaller than that of GTV(CONV) (p = 0.0006). There was no statistically significant difference between the maximum dose (p = 0.0585) and the mean dose (p = 0.2748) of PTV. The radiotherapy treatment plan based on the new gross tumor volume (PLAN(NEW)) significantly reduced maximum doses to the cerebrum and cerebellum (p = 0.0418) and to brain stem (p = 0.0041). Conclusion: Results of the present study suggest that the new brain PET system using semiconductor detectors can provide more accurate tumor delineation than the conventional whole-body BGO PET system and may be an important tool for functional and molecular radiotherapy treatment planning. (C) 2012 Elsevier Inc.
引用
收藏
页码:E671 / E676
页数:6
相关论文
共 50 条
  • [31] Impact of 18f-deoxyglucose positron emission tomography (FDG-PET) image fusion on radiotherapy target delineation and treatment outcome in advanced oesophageal carcinoma.
    Bodet-Milin, C.
    Marchand, V.
    Oudoux, A.
    Bridji, B.
    Resche, I.
    Kraeber-Bodere, F.
    Mahe, M.
    Rousseau, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S97 - S97
  • [32] Partial Volume Correction for Equivocal Retropharyngeal Nodal Metastases of Nasopharyngeal Carcinoma with Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography
    Wang, Yu-Wen
    Wu, Chin-Shun
    Chang, Chih-Han
    Cheng, Kuo-Sheng
    Chang, Yu-Kang
    Huang, I-Wen
    Lu, Chin-Li
    Yao, Wei-Jen
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 35 (02) : 218 - 225
  • [33] C-11-methionine positron emission tomography for target delineation of recurrent glioblastoma in re-irradiation planning
    Tanaka, Hidekazu
    Yamaguchi, Takahiro
    Hachiya, Kae
    Miwa, Kazuhiro
    Shinoda, Jun
    Hayashi, Masahide
    Ogawa, Shinichi
    Nishibori, Hironori
    Goshima, Satoshi
    Matsuo, Masayuki
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (03) : 215 - 219
  • [34] Comparison of positron emission tomography (PET) and computed tomography (CT) for better target volume definition in radiation therapy planning
    Antoni Vila
    Alberto Sánchez-Reyes
    Carles Conill
    Juan Domingo Gispert
    Carlos Trampal
    Carmen Láinez
    Jordi Vayreda
    Agustí Pedro
    Clinical and Translational Oncology, 2010, 12 : 367 - 373
  • [35] Comparison of positron emission tomography (PET) and computed tomography (CT) for better target volume definition in radiation therapy planning
    Vila, Antoni
    Sanchez-Reyes, Alberto
    Conill, Carles
    Domingo Gispert, Juan
    Trampal, Carlos
    Lainez, Carmen
    Vayreda, Jordi
    Pedro, Agusti
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2010, 12 (05): : 367 - 373
  • [36] The potential advantages of 18 F sodium fluoride positron emission tomography-computed tomography for clinical staging and management planning in patients with nasopharyngeal carcinoma
    Wang, Dong
    Guo, Chengmao
    Xiao, Jingxing
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (05) : 3393 - 3404
  • [37] Hierarchical and Adaptive Volume-growing Methods for the PET based Biologic Target Volume Delineation for Radiotherapy Treatment Planning
    Liu, Guocai
    Zhu, Suyu
    Wang, Yaonan
    Zhang, Jiutang
    Hu, Bingqiang
    ZhihaoYu
    Wu, Haiyan
    Yang, Weili
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4293 - 4295
  • [38] Automated biological target volume delineation for radiotherapy treatment planning using FDG-PET/CT
    Niyazi, Maximilian
    Landrock, Sonja
    Elsner, Andreas
    Manapov, Farkhad
    Hacker, Marcus
    Belka, Claus
    Ganswindt, Ute
    RADIATION ONCOLOGY, 2013, 8
  • [39] Automated biological target volume delineation for radiotherapy treatment planning using FDG-PET/CT
    Maximilian Niyazi
    Sonja Landrock
    Andreas Elsner
    Farkhad Manapov
    Marcus Hacker
    Claus Belka
    Ute Ganswindt
    Radiation Oncology, 8
  • [40] Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET)
    Erdi, YE
    Rosenzweig, K
    Erdi, AK
    Macapinlac, HA
    Hu, YC
    Braban, LE
    Humm, JL
    Squire, OD
    Chui, CS
    Larson, SM
    Yorke, ED
    RADIOTHERAPY AND ONCOLOGY, 2002, 62 (01) : 51 - 60