Hierarchical and Adaptive Volume-growing Methods for the PET based Biologic Target Volume Delineation for Radiotherapy Treatment Planning

被引:0
|
作者
Liu, Guocai [1 ]
Zhu, Suyu [2 ]
Wang, Yaonan [1 ]
Zhang, Jiutang [2 ]
Hu, Bingqiang [2 ]
ZhihaoYu [1 ]
Wu, Haiyan [1 ]
Yang, Weili [1 ]
机构
[1] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Prov Canc Hosp, Dept Radiat Oncol, Changsha, Hunan, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To more accurately and precisely delineate a biologic target volume (BTV) for PET-guided radiotherapy treatment planning, we proposed a novel tumor segmentation method by hierarchically utilizing an adaptive volume-growing algorithm (AVGA). First, a rough volume of interest (VOI) is manually cut by a radiation oncologist that encloses a tumor volume. The voxel having the highest standard uptake values (SUV) in the manual VOI is chosen as a seed of the first AVGA. One of all 6-neighboring voxels (N-6) of the current tumor volume (CTV) is successively appended to the CTV. The growing criterion of the AVAG is that the SUV of the appended voxel is higher than the mean SUV of the CTV multiplied by a threshold value, and its SUV subtracted from the mean SUV of the CTV is a minimum in the N-6. We have always observed a sharp volume growth at a certain threshold value T-1 between 0.3 and 0.7, in which case many voxels outside of the delineated tumor volume are appended to the CTV. So, the first AVGA is stopped just before the sharp volume growth and the second AVGA is launched to refine the BTV delineation. The resulting CTV by the first AVGA is chosen as a seed volume of the second AVGA, and the threshold varies from T-1 to 0.30 with an adding growing criterion which the SUV of the current appended voxel is not higher than one of the last appended voxel. The idea behind is high-noise characteristics, partial volume effects due to the low spatial resolution, the tumor extension with lower SUV, and the spillover effects of some PET images. Patient studies were tested and evaluated by an experienced radiation oncologist. The results demonstrated that the proposed method can more accurately and precisely delineate a BTV due to the second AVGA. This method can automatically process PET images with different sizes of tumor volume and different signal to background ratios (SBR). The resulting BTV is reproducible and also independent of the initial VOI
引用
收藏
页码:4293 / 4295
页数:3
相关论文
共 50 条
  • [1] COMPARISON BETWEEN CT-TARGET VOLUME DELINEATION AND DIFFERENT METHODS OF FDG-PET TARGET VOLUME DELINEATION FOR RADIOTHERAPY PLANNING OF NSCLC
    Rodari, M.
    Navarria, P.
    Lattuada, P.
    Scorsetti, M.
    Chiti, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 : S18 - S19
  • [2] Automated biological target volume delineation for radiotherapy treatment planning using FDG-PET/CT
    Niyazi, Maximilian
    Landrock, Sonja
    Elsner, Andreas
    Manapov, Farkhad
    Hacker, Marcus
    Belka, Claus
    Ganswindt, Ute
    RADIATION ONCOLOGY, 2013, 8
  • [3] Automated biological target volume delineation for radiotherapy treatment planning using FDG-PET/CT
    Maximilian Niyazi
    Sonja Landrock
    Andreas Elsner
    Farkhad Manapov
    Marcus Hacker
    Claus Belka
    Ute Ganswindt
    Radiation Oncology, 8
  • [4] Optimising radiotherapy for bone metastases by target volume delineation and individualised treatment planning
    Albert, A.
    Patel, A.
    Van, E. Mierlo
    Nouwens, I.
    Hol, S.
    Smits, W.
    Verhoof, D.
    Van der Linden, L.
    Raaijmakers, E.
    Poortmans, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S231 - S232
  • [5] PET-based target volume delineation: new methods and their evaluation
    Shepherd, T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (09) : 593 - 593
  • [6] PET IN TARGET VOLUME DELINEATION AND DOSE PLANNING FOR OESOPHAGEAL CANCER
    Muijs, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S225 - S225
  • [7] Radiotherapy planning for glioblastoma based on a tumor growth model: improving target volume delineation
    Unkelbach, Jan
    Menze, Bjoern H.
    Konukoglu, Ender
    Dittmann, Florian
    Le, Matthieu
    Ayache, Nicholas
    Shih, Helen A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : 747 - 770
  • [8] FDG PET/CT for radiotherapy treatment planning. Comparison of functional volume delineation algorithms
    Withofs, Nadia
    Bernard, Claire
    van der Rest, Catherine
    Martinive, Philippe
    Hatt, Mathieu
    Visvikis, Dimitris
    Coucke, Philippe
    Hustinx, Roland
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [9] FDG-PET/CT and MR imaging for target volume delineation in rectal cancer radiotherapy treatment planning: a systematic review
    Olanloye, Elizabeth E.
    Ramlaul, Aarthi
    Ntekim, Atara, I
    Adeyemi, Segun S.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (04) : 529 - 539
  • [10] Comparison of different methods of FDG-PET target volume delineation in the radiotherapy of head and neck cancer
    Greco, C.
    Nehmeh, S.
    Shoder, H.
    Gonen, M.
    Raphael, B.
    Stambuk, H.
    Humm, J.
    Lee, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S422 - S422