A New Brain Positron Emission Tomography Scanner With Semiconductor Detectors for Target Volume Delineation and Radiotherapy Treatment Planning in Patients With Nasopharyngeal Carcinoma

被引:7
|
作者
Katoh, Norio [1 ]
Yasuda, Koichi [1 ]
Shiga, Tohru [2 ,3 ]
Hasegawa, Masakazu [1 ]
Onimaru, Rikiya [1 ]
Shimizu, Shinichi [1 ]
Bengua, Gerard
Ishikawa, Masayori
Tamaki, Nagara [2 ,3 ]
Shirato, Hiroki [1 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Radiat Med, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ, Grad Sch Med, Dept Med Phys, Sapporo, Hokkaido 0608638, Japan
关键词
Nasopharyngeal carcinoma; Positron emission tomography; Radiotherapy planning; Semiconductor; Target volume delineation; STANDARD UPTAKE VALUE; CELL LUNG-CANCER; NECK-CANCER; TUMOR VOLUME; FDG-PET; HEAD; CT; FUSION; DEFINITION; SPECIMEN;
D O I
10.1016/j.ijrobp.2011.09.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We compared two treatment planning methods for stereotactic boost for treating nasopharyngeal carcinoma (NPC): the use of conventional whole-body bismuth germanate (BGO) scintillator positron emission tomography (PETCONVWB) versus the new brain (BR) PET system using semiconductor detectors (PETNEWBR). Methods and Materials: Twelve patients with NPC were enrolled in this study. [F-18]Fluorodeoxyglucose-PET images were acquired using both the PETNEWBR and the PETCONVWB system on the same day. Computed tomography (CT) and two PET data sets were transferred to a treatment planning system, and the PETCONVWB and PETNEWBR images were coregistered with the same set of CT images. Window width and level values for all PET images were fixed at 3000 and 300, respectively. The gross tumor volume (GTV) was visually delineated on PET images by using either PETCONVWB (GTV(CONV)) images or PETNEWBR (GTV(NEW)) images. Assuming a stereotactic radiotherapy boost of 7 ports, the prescribed dose delivered to 95% of the planning target volume (PTV) was set to 2000 cGy in 4 fractions. Results: The average absolute volume (+/- standard deviation [SD]) of GTV(NEW) was 15.7 ml (+/- 9.9) ml, and that of GTV(CONV) was 34.0 (+/- 20.5) ml. The average GTV(NEW) was significantly smaller than that of GTV(CONV) (p = 0.0006). There was no statistically significant difference between the maximum dose (p = 0.0585) and the mean dose (p = 0.2748) of PTV. The radiotherapy treatment plan based on the new gross tumor volume (PLAN(NEW)) significantly reduced maximum doses to the cerebrum and cerebellum (p = 0.0418) and to brain stem (p = 0.0041). Conclusion: Results of the present study suggest that the new brain PET system using semiconductor detectors can provide more accurate tumor delineation than the conventional whole-body BGO PET system and may be an important tool for functional and molecular radiotherapy treatment planning. (C) 2012 Elsevier Inc.
引用
收藏
页码:E671 / E676
页数:6
相关论文
共 50 条
  • [21] Prognostic Value of Volume-Based Positron Emission Tomography/Computed Tomography in Nasopharyngeal Carcinoma Patients after Comprehensive Therapy
    Tian, Yueli
    Bakari, Khamis Hassan
    Liao, Shanshan
    Xia, Xiaotian
    Sun, Xun
    Qin, Chunxia
    Zhang, Yongxue
    Lan, Xiaoli
    CONTRAST MEDIA & MOLECULAR IMAGING, 2018,
  • [22] Prognostic Value of Volume-Based Positron Emission Tomography/Computed Tomography in Patients With Nasopharyngeal Carcinoma Treated With Concurrent Chemoradiotherapy
    Moon, Seung Hwan
    Choi, Joon Young
    Lee, Hwan Joo
    Son, Young-Ik
    Baek, Chung-Hwan
    Ahn, Yong Chan
    Ahn, Myung-Ju
    Park, Keunchil
    Kim, Byung-Tae
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2015, 8 (02) : 142 - 148
  • [23] 18F-Octreotate positron emission tomography (PET) for target volume delineation in stereotactic radiation therapy planning of glomus tumors
    Robinson, C.
    Lyons, J.
    Evans, P.
    Lawton, J.
    Graham, T.
    Polster, J.
    Suhl, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S545 - S546
  • [24] Target volume delineation for radical radiotherapy of early oesophageal carcinoma in elderly patients
    Su, J.
    Zhu, S.
    Liu, Z.
    Zhao, Y.
    Song, C.
    CANCER RADIOTHERAPIE, 2017, 21 (01): : 34 - 39
  • [25] Effectiveness of Respiratory-gated Positron Emission Tomography/Computed Tomography for Radiotherapy Planning in Patients with Lung Carcinoma - A Systematic Review
    Frood, R.
    Prestwich, R.
    Tsoumpas, C.
    Murray, P.
    Franks, K.
    Scarsbrook, A.
    CLINICAL ONCOLOGY, 2018, 30 (04) : 225 - 232
  • [26] Defining the Target in Cancer of the Oesophagus: Direct Radiotherapy Planning with Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography
    le Grange, F.
    Wickers, S.
    Warry, A.
    Warrilow, J.
    Bomanji, J.
    Tobias, J. S.
    CLINICAL ONCOLOGY, 2015, 27 (03) : 160 - 167
  • [27] Dosimetric impact of amino acid positron emission tomography imaging for target delineation in radiation treatment planning for high-grade gliomas
    Kazda, Tomas
    Pafundi, Deanna H.
    Kraling, Alan
    Bradley, Thomas
    Lowe, Val J.
    Brinkmann, Debra H.
    Laack, Nadia N.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 : 94 - 100
  • [28] Partial Volume Correction for Equivocal Retropharyngeal Nodal Metastases of Nasopharyngeal Carcinoma with Fluorodeoxyglucose Positron Emission Tomography–Computed Tomography
    Yu-Wen Wang
    Chin-Shun Wu
    Chih-Han Chang
    Kuo-Sheng Cheng
    Yu-Kang Chang
    I-Wen Huang
    Chin-Li Lu
    Wei-Jen Yao
    Journal of Medical and Biological Engineering, 2015, 35 : 218 - 225
  • [29] The value of positron-emission tomography/computed tomography for radiotherapy treatment planning: a single institutional series
    Marta, Gustavo Nader
    Hanna, Samir Abdallah
    Sa de Camargo Etchebehere, Elba Cristina
    Camargo, Edwaldo Eduardo
    Kalil Haddad, Cecilia Maria
    Fernandes da Silva, Joao Luis
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (10) : 903 - 907
  • [30] Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning
    Zamora, David A.
    Riegel, Adam C.
    Sun, Xiaojun
    Balter, Peter
    Starkschall, George
    Mawlawi, Osama
    Pan, Tinsu
    MEDICAL PHYSICS, 2010, 37 (11) : 5811 - 5820