Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture

被引:2
|
作者
Sung, Ji-Hee [1 ]
Cha, Hyun-Hwa [2 ,3 ]
Lee, Nan-Young [4 ]
Lee, Won-Ki [5 ]
Choi, Yeseul [6 ]
Han, Hyung-Soo [7 ]
Lee, Yoo-Young [1 ]
Chong, Gun-Oh [2 ,3 ]
Seong, Won-Joon [2 ,3 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Obstet & Gynecol, Sch Med, Seoul 06351, South Korea
[2] Kyungpook Natl Univ, Dept Obstet & Gynecol, Chilgok Hosp, Daegu 41404, South Korea
[3] Kyungpook Natl Univ, Sch Med, Dept Obstet & Gynecol, Daegu 41404, South Korea
[4] Kyungpook Natl Univ, Chilgok Hosp, Sch Med, Dept Lab Med, Daegu 41404, South Korea
[5] Kyungpook Natl Univ, Sch Med, Dept Med Informat, Daegu 41944, South Korea
[6] Kyungpook Natl Univ, Clin Omics Res Ctr, Sch Med, Daegu 41940, South Korea
[7] Kyungpook Natl Univ, Sch Med, Dept Physiol, Daegu 41405, South Korea
关键词
group B streptococcus; diagnosis; loop-mediated isothermal amplification assay; polymerase chain reaction assay; COLONIZATION;
D O I
10.3390/diagnostics12071569
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A rapid method for obtaining group B streptococcus (GBS) screening results has been required in the obstetric field. We aimed to determine the diagnostic performance of the Loop-Mediated Isothermal Amplification (LAMP) assay is acceptable compared to the existing polymerase chain reaction (PCR) assay. The study involved 527 pregnant women aged 19 to 44 years. Rectovaginal swabs were collected between 35 and 37 weeks of gestation or prior to impending preterm births or term labor without GBS screening. We presented the diagnostic performance of the LAMP assay with a 95% confidence interval (CI) compared to the PCR and microbiological culture. In total, 115 (21.8%), 115 (21.8%) and 23 (4.4%) patients showed positive results using the LAMP, PCR assay and microbiological culture method, respectively. The LAMP assay showed 100% sensitivity (95% CI, 96.8-100.0), 100% specificity (95% CI, 99.1-100.0) and 100% diagnostic accuracy (95% CI, 99.3-100.0) with the reference being the PCR assay. Meanwhile, the LAMP assay showed 87.0% sensitivity (95% CI, 71.0-100.0), 81.2% specificity (95% CI, 77.6-84.7), and 81.4% diagnostic accuracy (95% CI, 78.0-84.8) with the microbiological culture as a reference. This study presented the LAMP assay as an acceptable method for GBS screening with a similar performance to the existing PCR method.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [41] A simple, rapid and solvent free nucleic acid extraction protocol for detection of banana bunchy top virus by polymerase chain reaction and loop-mediated isothermal amplification
    Ramasamy Selvarajan
    Veluswamy Balasubramanian
    Thirunavukarasu Sasireka
    European Journal of Plant Pathology, 2015, 142 : 389 - 396
  • [42] Diagnostic Accuracy of Loop-mediated Isothermal Amplification Assay as a Field Molecular Tool for Rapid Mass Screening of Old World Leishmania Infections in Sand Flies and In Vitro Culture
    Ghodrati, Mehdi
    Spotin, Adel
    Hazratian, Teimour
    Mahami-Oskouei, Mahmoud
    Bordbar, Ali
    Ebrahimi, Sahar
    Fallahi, Shirzad
    Parvizi, Parviz
    IRANIAN JOURNAL OF PARASITOLOGY, 2017, 12 (04) : 506 - 515
  • [43] A simple, rapid and solvent free nucleic acid extraction protocol for detection of banana bunchy top virus by polymerase chain reaction and loop-mediated isothermal amplification
    Selvarajan, Ramasamy
    Balasubramanian, Veluswamy
    Sasireka, Thirunavukarasu
    EUROPEAN JOURNAL OF PLANT PATHOLOGY, 2015, 142 (02) : 389 - 396
  • [44] Comparison of real-time reverse transcription loop-mediated isothermal amplification and real-time reverse transcription polymerase chain reaction for duck Tembusu virus
    Yan, Liping
    Peng, Shan
    Yan, Pixi
    Zhou, Jiewen
    Teng, Qiaoyang
    Li, Guoxin
    Li, Xuesong
    Li, Zejun
    JOURNAL OF VIROLOGICAL METHODS, 2012, 182 (1-2) : 50 - 55
  • [45] Comparison of real-time reverse-transcription loop-mediated isothermal amplification and real-time reverse-transcription polymerase chain reaction for detection of noroviruses in municipal wastewater
    Suzuki, Yoshihiro
    Narimatsu, Shogo
    Furukawa, Takashi
    Iwakiri, Akira
    Miura, Miho
    Yamamoto, Shogo
    Katayama, Hiroyuki
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2011, 112 (04) : 369 - 372
  • [46] COMPARISON OF ANALYTICAL SENSITIVITY AND SPECIFICITY OF REVERSE TRANSCRIPTION LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (RT-LAMP) AND REVERSE TRANSCRIPTION POLYMERASE CHAIN REACTION (RT-PCR) FOR DETECTION OF LOCAL PESTIVIRUS A
    Hammad-ur-Rehman
    Ahmad, A.
    Rabbani, M.
    Tipu, M. Y.
    JOURNAL OF ANIMAL AND PLANT SCIENCES, 2020, 30 (01): : 50 - 57
  • [47] Comparison of loop-mediated isothermal amplification (LAMP) and real-time polymerase chain reaction methods using reverse transcriptase (qRT-PCR) as molecular diagnostic methods of Sars Cov 2
    Rodriguez, George Adan Galdos
    Manrique, Andrea del Rosario Atahualpa
    Carbajal, Dolly Solange Zeballos
    REVISTA DEL CUERPO MEDICO DEL HOSPITAL NACIONAL ALMANZOR AGUINAGA ASENJO, 2023, 16 (03):
  • [48] Comparison of colorimetric loop-mediated isothermal amplification kit and reverse transcription-polymerase chain reaction in the diagnosis of peste des petits ruminants in sheep and goats in Southeast Nigeria
    Chukwudi, Ijeoma Chekwube
    Ogbu, Kenneth Ikejiofor
    Luka, Pam Dachung
    Malesa, Refiloe Petunia
    Heath, Livio Edward
    Ugochukwu, Emmanuel Ikenna
    Chah, Kennedy Foinkfu
    VETERINARY WORLD, 2020, 13 (11) : 2358 - 2363
  • [49] Prospective evaluation of the Meridian Illumigene™ loop-mediated amplification assay and the Gen Probe ProGastro™ Cd polymerase chain reaction assay for the direct detection of toxigenic Clostridium difficile from fecal samples
    Doing, Kirk M.
    Hintz, Marilyn S.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 72 (01) : 8 - 13
  • [50] Comparison of Diagnostic Yield of Tuberculosis Loop-Mediated Isothermal Amplification Assay With Cartridge-Based Nucleic Acid Amplification Test, Acid-Fast Bacilli Microscopy, and Mycobacteria Growth Indicator Tube Culture in Children With Pulmonary Tuberculosis
    Dayal, Rajeshwar
    Yadav, Alok
    Agarwal, Dipti
    Kumar, Manoj
    Kamal, Raj
    Singh, Dharmendra
    Bhatnagar, Shailendra