Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture

被引:2
|
作者
Sung, Ji-Hee [1 ]
Cha, Hyun-Hwa [2 ,3 ]
Lee, Nan-Young [4 ]
Lee, Won-Ki [5 ]
Choi, Yeseul [6 ]
Han, Hyung-Soo [7 ]
Lee, Yoo-Young [1 ]
Chong, Gun-Oh [2 ,3 ]
Seong, Won-Joon [2 ,3 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Obstet & Gynecol, Sch Med, Seoul 06351, South Korea
[2] Kyungpook Natl Univ, Dept Obstet & Gynecol, Chilgok Hosp, Daegu 41404, South Korea
[3] Kyungpook Natl Univ, Sch Med, Dept Obstet & Gynecol, Daegu 41404, South Korea
[4] Kyungpook Natl Univ, Chilgok Hosp, Sch Med, Dept Lab Med, Daegu 41404, South Korea
[5] Kyungpook Natl Univ, Sch Med, Dept Med Informat, Daegu 41944, South Korea
[6] Kyungpook Natl Univ, Clin Omics Res Ctr, Sch Med, Daegu 41940, South Korea
[7] Kyungpook Natl Univ, Sch Med, Dept Physiol, Daegu 41405, South Korea
关键词
group B streptococcus; diagnosis; loop-mediated isothermal amplification assay; polymerase chain reaction assay; COLONIZATION;
D O I
10.3390/diagnostics12071569
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A rapid method for obtaining group B streptococcus (GBS) screening results has been required in the obstetric field. We aimed to determine the diagnostic performance of the Loop-Mediated Isothermal Amplification (LAMP) assay is acceptable compared to the existing polymerase chain reaction (PCR) assay. The study involved 527 pregnant women aged 19 to 44 years. Rectovaginal swabs were collected between 35 and 37 weeks of gestation or prior to impending preterm births or term labor without GBS screening. We presented the diagnostic performance of the LAMP assay with a 95% confidence interval (CI) compared to the PCR and microbiological culture. In total, 115 (21.8%), 115 (21.8%) and 23 (4.4%) patients showed positive results using the LAMP, PCR assay and microbiological culture method, respectively. The LAMP assay showed 100% sensitivity (95% CI, 96.8-100.0), 100% specificity (95% CI, 99.1-100.0) and 100% diagnostic accuracy (95% CI, 99.3-100.0) with the reference being the PCR assay. Meanwhile, the LAMP assay showed 87.0% sensitivity (95% CI, 71.0-100.0), 81.2% specificity (95% CI, 77.6-84.7), and 81.4% diagnostic accuracy (95% CI, 78.0-84.8) with the microbiological culture as a reference. This study presented the LAMP assay as an acceptable method for GBS screening with a similar performance to the existing PCR method.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [31] Comparison of reverse-transcription loop-mediated isothermal amplification and reverse-transcription polymerase chain reaction for grass carp reovirus
    Yang, Shuixian
    Wang, Kai-Yu
    Yang, Zexiao
    ACTA VETERINARIA BRNO, 2015, 84 (03) : 215 - 223
  • [32] Evaluation of Culture, Antigen Detection and Polymerase Chain Reaction for Detection of Vaginal Colonization of Group B Streptococcus (GBS) in Pregnant Women
    Konikkara, Kavitha Paul
    Baliga, Shrikala
    Shenoy, Suchithra
    Bharati, B.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (02) : 47 - 49
  • [33] Diagnostic Accuracy of a Rapid Real-Time Polymerase Chain Reaction Assay for Universal Intrapartum Group B Streptococcus Screening
    El Helali, Najoua
    Nguyen, Jean-Claude
    Ly, Aicha
    Giovangrandi, Yves
    Trinquart, Ludovic
    CLINICAL INFECTIOUS DISEASES, 2009, 49 (03) : 417 - 423
  • [34] Rapid and Sensitive Loop-Mediated Isothermal Amplification Test for Clostridium difficile Detection Challenges Cytotoxin B Cell Test and Culture as Gold Standard
    Noren, Torbjorn
    Alriksson, Ingegard
    Andersson, Josefin
    Akerlund, Thomas
    Unemo, Magnus
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (02) : 710 - 711
  • [35] Detection of severe acute respiratory syndrome coronavirus 2 in bioaerosols using digital droplet polymerase chain reaction and loop-mediated isothermal amplification
    Zhang, Xinyu
    Guan, Yuhong
    Li, Song
    Deng, Yan
    Wu, Yanqi
    Chen, Hui
    Analytical Methods, 2024, 16 (48) : 8449 - 8456
  • [36] COMPARISON OF NESTED-POLYMERASE CHAIN REACTION AND LOOP-MEDIATED ISOTHERMAL AMPLIFICATION IN DETECTION OF CRYPTOSPORIDIUM SPP AND GIARDIA DUODENALIS FROM WATER SOURCES IN PHAYAO PROVINCE, THAILAND
    Tantiamornkul, Kritpaphat
    Mataradchakul, Touchchapol
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2019, 50 (01) : 13 - 24
  • [37] Comparison of the Cobas Liat Influenza A/B Polymerase Chain Reaction Assay and the Alere i Influenza A and B Isothermal Amplification Assay for the Detection of Influenza in Adults
    Young, S.
    Villanueva, J.
    Illescas, P.
    Nicasio, J.
    Sickler, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2016, 18 (06): : 985 - 986
  • [38] Evaluation of diagnostic accuracy of loop-mediated isothermal amplification method (LAMP) compared with polymerase chain reaction (PCR) for Leptospira spp. in clinical samples: a systematic review and meta-analysis
    Gunasegar, Shan
    Neela, Vasantha Kumari
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2021, 100 (03)
  • [39] Loop mediated isothermal amplification assay using hydroxy naphthol blue, conventional polymerase chain reaction and real-time PCR in the diagnosis of intraocular tuberculosis
    Balne, P. K.
    Basu, S.
    Rath, S.
    Barik, M. R.
    Sharma, S.
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 33 (04) : 568 - 571
  • [40] Accuracy of reverse-transcription polymerase chain reaction and loop-mediated isothermal amplification in diagnosing severe fever with thrombocytopenia syndrome: A systematic review and meta-analysis
    Tian, Wen
    Ren, Xingxiang
    Gao, Xu
    Zhang, Yuanyuan
    Chen, Zhihai
    Zhang, Wei
    JOURNAL OF MEDICAL VIROLOGY, 2022, 94 (12) : 5922 - 5932