Module for measurement of CO2 concentration in exhaled air

被引:0
|
作者
Puton, JW [1 ]
Palko, T [1 ]
Knap, A [1 ]
Jasek, K [1 ]
Siodlowski, B [1 ]
机构
[1] Mil Univ Technol, PL-00908 Warsaw, Poland
关键词
non-dispersive infrared gas analysis; carbon dioxide; capnometry; calibration;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of this work consists in working out of a detection module for capnography (carbon dioxide concentration measurement in anaesthesiology and intensive care). The principle of operation of the module consists of the NDIR method. The basic assumption for construction of this model was using of directly modulated thermal IR source in it. A few models of IR sources were worked out. Their heaters were made from thick platinum layers and foil. Limits of modulation frequency for IR sources were greater than 30 Hz. The detection module consists of an optical-part, analogue electronics and microprocessor system with a suitable program. The time dependent concentration of CO2, end tidal concentration Of CO2, mean concentration of N2O and breath frequency are output values of the detection module. Measurements are executed 30 times per second. The accuracy Of CO2 Concentration measurement equals to 5%.
引用
收藏
页码:278 / 282
页数:5
相关论文
共 50 条
  • [32] Effect of measurement CO2 concentration on sugar maple root respiration
    Burton, AJ
    Zogg, GP
    Pregitzer, KS
    Zak, DR
    TREE PHYSIOLOGY, 1997, 17 (07) : 421 - 427
  • [33] Measurement of CO2 concentration based on supercontinuum laser absorption spectroscopy
    Li Hong-lian
    Di Shuai
    Li Wen-duo
    Lu Wen-jing
    Wang Fan
    Fang Li-de
    OPTOELECTRONICS LETTERS, 2021, 17 (03) : 176 - 182
  • [34] A new space instrument concept for the measurement of CO2 concentration in the atmosphere
    Buil, Christian
    Pascal, Veronique
    Loesel, Jacques
    Pierangelo, Clemence
    Roucayrol, Lionel
    Tauziede, Laurie
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XV, 2011, 8176
  • [35] A study of atmospheric CO2 concentration based on the technology of infrared measurement
    Shang, LP
    Zheng, DZ
    Zhang, XB
    OPTICAL MEASUREMENT AND NONDESTRUCTIVE TESTING: TECHNIQUES AND APPLICATIONS, 2000, 4221 : 167 - 170
  • [36] Measurement of CO2 concentration based on supercontinuum laser absorption spectroscopy
    Hong-lian Li
    Shuai Di
    Wen-duo Li
    Wen-jing Lü
    Fan Wang
    Li-de Fang
    Optoelectronics Letters, 2021, 17 : 176 - 182
  • [37] Measurement of CO2 concentration based on supercontinuum laser absorption spectroscopy
    李红莲
    邸帅
    李文铎
    吕文静
    王帆
    方立德
    Optoelectronics Letters, 2021, 17 (03) : 176 - 182
  • [38] Effect of CO2 concentration on the electrolytic conversion of CO2 to CO
    Liu, Zengcai
    Yang, Hongzhou
    Sajjad, Syed
    Kaczur, Jerry
    Masel, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [39] MEASUREMENT OF SEA-AIR CO2 FLUX BY EDDY CORRELATION
    JONES, EP
    SMITH, SD
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1977, 58 (08): : 822 - 822
  • [40] USE OF EXHALED CO2 DETECTOR FOR NEONATAL INTUBATION
    Gupta, A.
    Ganesan, K.
    Oddie, S.
    PEDIATRIC RESEARCH, 2010, 68 : 568 - 568