The objective of this work consists in working out of a detection module for capnography (carbon dioxide concentration measurement in anaesthesiology and intensive care). The principle of operation of the module consists of the NDIR method. The basic assumption for construction of this model was using of directly modulated thermal IR source in it. A few models of IR sources were worked out. Their heaters were made from thick platinum layers and foil. Limits of modulation frequency for IR sources were greater than 30 Hz. The detection module consists of an optical-part, analogue electronics and microprocessor system with a suitable program. The time dependent concentration of CO2, end tidal concentration Of CO2, mean concentration of N2O and breath frequency are output values of the detection module. Measurements are executed 30 times per second. The accuracy Of CO2 Concentration measurement equals to 5%.
引用
收藏
页码:278 / 282
页数:5
相关论文
共 50 条
  • [41] Paediatric exhaled CO2 detector causes leaks
    Martherus, Tessa
    den Hoed, Annika
    Cramer, Sophie J. E.
    Tan, Ratna N. G. B.
    Hooper, Stuart B.
    te Pas, Arjan B.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2020, 105 (04): : F441 - F443
  • [42] Development and Validation of a Methodology to Measure Exhaled Carbon Dioxide (CO2) and Control Indoor Air Renewal
    Baselga, Marta
    Alba, Juan J.
    Schuhmacher, Alberto J.
    COVID, 2023, 3 (12): : 1797 - 1817
  • [43] Measurement Module of Dispersion Interferometer Based on the CO2 Laser for Plasma Density Control
    S. V. Ivanenko
    K. A. Grinemayer
    E. A. Puryga
    A. N. Kvashnin
    P. A. Bagryansky
    Physics of Atomic Nuclei, 2023, 86 : 1673 - 1682
  • [44] Measurement Module of Dispersion Interferometer Based on the CO2 Laser for Plasma Density Control
    Ivanenko, S. V.
    Grinemayer, K. A.
    Puryga, E. A.
    Kvashnin, A. N.
    Bagryansky, P. A.
    PHYSICS OF ATOMIC NUCLEI, 2023, 86 (07) : 1673 - 1682
  • [45] Effect of CO2 concentration in air on electrolytic conductivity of aqueous solutions of KCl
    Amico Di Meane, E
    Durbiano, F
    ANNALI DI CHIMICA, 2004, 94 (5-6) : 463 - 468
  • [46] Experimental determination of natural air ventilation rates based on CO2 concentration
    Costanzo, S.
    Cusumano, A.
    Giaconia, C.
    Valdiserri, P.
    RECENT ADVANCES IN ENERGY AND ENVIRONMENT: PROCEEDINGS OF THE 4TH IASME/WSEAS INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT (EE'09), 2009, : 383 - +
  • [47] STUDIES IN RIBULOSOBISPHOSPHATE CARBOXYLASE RENEWAL AT DIFFERENT LEVELS OF CO2 CONCENTRATION IN THE AIR
    GRODZINSKY, DM
    VISHENSKAYA, IG
    FIZIOLOGIYA I BIOKHIMIYA KULTURNYKH RASTENII, 1988, 20 (04): : 338 - 341
  • [48] CO2 from air
    Burke, Maria
    CHEMISTRY & INDUSTRY, 2018, 82 (06) : 15 - 15
  • [49] AIRBORNE CO2 DIAL MEASUREMENT OF ATMOSPHERIC TRACER GAS CONCENTRATION DISTRIBUTIONS
    UTHE, EE
    APPLIED OPTICS, 1986, 25 (15): : 2492 - 2498
  • [50] A trend of the CO2 concentration in tree rings and the atmospheric CO2
    Ageev B.G.
    Ponomarev Y.N.
    Sapozhnikova V.A.
    Atmospheric and Oceanic Optics, 2009, 22 (1) : 128 - 134