The metal-organic framework HKUST-1 as efficient sorbent in a vortex-assisted dispersive micro solid-phase extraction of parabens from environmental waters, cosmetic creams, and human urine

被引:152
|
作者
Rocio-Bautista, Priscilla [1 ]
Martinez-Benito, Carla [2 ]
Pino, Veronica [1 ]
Pasan, Jorge [2 ]
Ayala, Juan H. [1 ]
Ruiz-Perez, Catalina [2 ]
Afonso, Ana M. [1 ]
机构
[1] Univ La Laguna, Dept Chem, Analyt Div, E-38206 Tenerife, Spain
[2] Univ La Laguna, Dept Phys, X Ray & Mol Mat Lab MATMOL, E-38206 Tenerife, Spain
关键词
Metal-organic frameworks; Dispersive solid-phase extraction; Micro-solid-phase extraction; Parabens; Personal care products; Vortex-assisted methods; Environmental waters; Cosmetic creams; Human urine; POLYCYCLIC AROMATIC-HYDROCARBONS; PERFORMANCE LIQUID-CHROMATOGRAPHY; PECTINATA MEDICINAL-PLANT; COORDINATION POLYMER; GAS-CHROMATOGRAPHY; MICROEXTRACTION; ADSORPTION; PESTICIDES; ADSORBENT; PRECONCENTRATION;
D O I
10.1016/j.talanta.2015.02.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three metal-organic frameworks (MOFs), specifically HKUST-1, MOF-5, and MIL-53(AI), have been synthetized, characterized, studied and compared in a vortex-assisted dispersive micro-solid-phase extraction (VA-D-mu-SPE) procedure in combination with high-performance liquid chromatography (HPLC) with diode-array detection (DAD) for determining seven parabens in environmental waters (tap water, swimming pool water, and water coming from a spa pool), human urine (from two volunteers), and cosmetic creams (two commercial brands). Experimental parameters, such as nature and amount of MOF, sample volume, nature of elution solvent and its amount, vortex and centrifugation time, among others, were properly optimized. HKUST-1 was the most adequate MOF to work with. Detection limits for the overall method down to 0.1 mu g L-1 for butylparaben (BPB) and benzylparaben (BzPB) were obtained, with determination coefficients (R-2) higher than 0.9966 for a range of 0.5-147 mu g L-1 (depending on the paraben), average relative recoveries (RR, in %) of 803% at the low spiked level (7 mu g L-1), and relative standard deviation (RSD) values below 10% also at the low spiked level. The strength of the affinity between HKUST-1 and parabens was evaluated, and it ranged from 33.5% for isopropylparaben (iPPB) to 77.0% for isobutylparaben (iBPB). When analyzing complex environmental waters, RR values of 78%, inter-day precision values (as RSD) lower than 15%, and intra-day precision values lower than 7.8% were obtained, despite the observed matrix effect. When analyzing cosmetic creams, parabens were detected, with contents ranging from 0.14 +/- 0.01 mu g g(-1) for EPB in the healing cream analyzed to 1.12 +/- 0.07 mg g(-1) for MPB in the mask cream analyzed, with precision values (RSD) lower than 12% and RR values from 63.7% for propylparaben (PPB) to 121% for iPPB. When analyzing human urine, no parabens were detected but the method could be performed with RSD values lower than 19%. These results show the adequateness of MOFs as sorbents in VA-D-mu-SPE procedures despite sample complexity. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [11] Application of a Zn(II) based metal-organic framework as an efficient solid-phase extraction sorbent for preconcentration of plasticizer compounds
    Tahmasebi, Elham
    Masoomi, Mohammad Yaser
    Yamini, Yadollah
    Morsali, Ali
    RSC ADVANCES, 2016, 6 (46): : 40211 - 40218
  • [12] Amine-Functionalized Metal–Organic Framework as a New Sorbent for Vortex-Assisted Dispersive Micro-Solid Phase Extraction of Phenol Residues in Water Samples Prior to HPLC Analysis: Experimental and Computational Studies
    Tittaya Boontongto
    Khatcharin Siriwong
    Rodjana Burakham
    Chromatographia, 2018, 81 : 735 - 747
  • [13] Metal organic framework derived composite as a new sorbent for micro-solid phase extraction of parabens from breast milk samples
    Haghgouei, Hanieh
    Seidi, Shahram
    Shirkhodaie, Mahsa
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1738
  • [14] Evaluation of metal-organic framework NH2-MIL-101(Fe) as an efficient sorbent for dispersive micro-solid phase extraction of phenolic pollutants in environmental water samples
    Boontongto, Tittaya
    Burakham, Rodjana
    HELIYON, 2019, 5 (11)
  • [15] Development and application of vortex-assisted membrane extraction based on metal-organic framework mixed-matrix membrane for the analysis of estrogens in human urine
    Gao, Guihua
    Li, Shuo
    Li, Sijia
    Zhao, Liang
    Wang, Ting
    Hou, Xiaohong
    ANALYTICA CHIMICA ACTA, 2018, 1023 : 35 - 43
  • [16] HKUST-1 metal-organic framework for dispersive solid phase extraction of 2-methyl-4-chlorophenoxyacetic acid (MCPA) prior to its determination by ion mobility spectrometry
    Masoumeh Mohammadnejad
    Zahra Gudarzi
    Shokoofeh Geranmayeh
    Vahideh Mahdavi
    Microchimica Acta, 2018, 185
  • [17] HKUST-1 metal-organic framework for dispersive solid phase extraction of 2-methyl-4-chlorophenoxyacetic acid (MCPA) prior to its determination by ion mobility spectrometry
    Mohammadnejad, Masoumeh
    Gudarzi, Zahra
    Geranmayeh, Shokoofeh
    Mahdavi, Vahideh
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [18] Efficient Solid-Phase Extraction of Neonicotinoid Insecticides from Environmental Water and Drink Samples Using a Postmodified Metal-Organic Framework
    Sun, Shi-Rong
    Sun, Qian-Yun
    Liu, Feng
    Zhao, Yan-Fang
    Wang, Xiao-Li
    Jiang, Hai-Long
    Li, Na
    Wu, Yong-Ning
    Liu, Lu
    Zhao, Ru-Song
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2024, 72 (40) : 22327 - 22335
  • [19] Cu (II)-based metal-organic framework functionalized with graphene oxide as a sorbent for the dispersive micro-solid-phase extraction of losartan potassium from water
    Valenzuela, Ivon E.
    Munoz-Acevedo, Juan Carlos
    Pabon, Elizabeth
    Paim, Ana Paula Silveira
    JOURNAL OF POROUS MATERIALS, 2024, 31 (05) : 1737 - 1752
  • [20] Determination of diuretics in human urine using HPLC coupled with magnetic solid-phase extraction based on a metal-organic framework
    Liu, Meng
    Lv, Bingqiang
    Jiang, Hailong
    Yuan, Pei
    Zhu, Huan
    Gao, Binghong
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (09)