The metal-organic framework HKUST-1 as efficient sorbent in a vortex-assisted dispersive micro solid-phase extraction of parabens from environmental waters, cosmetic creams, and human urine

被引:152
|
作者
Rocio-Bautista, Priscilla [1 ]
Martinez-Benito, Carla [2 ]
Pino, Veronica [1 ]
Pasan, Jorge [2 ]
Ayala, Juan H. [1 ]
Ruiz-Perez, Catalina [2 ]
Afonso, Ana M. [1 ]
机构
[1] Univ La Laguna, Dept Chem, Analyt Div, E-38206 Tenerife, Spain
[2] Univ La Laguna, Dept Phys, X Ray & Mol Mat Lab MATMOL, E-38206 Tenerife, Spain
关键词
Metal-organic frameworks; Dispersive solid-phase extraction; Micro-solid-phase extraction; Parabens; Personal care products; Vortex-assisted methods; Environmental waters; Cosmetic creams; Human urine; POLYCYCLIC AROMATIC-HYDROCARBONS; PERFORMANCE LIQUID-CHROMATOGRAPHY; PECTINATA MEDICINAL-PLANT; COORDINATION POLYMER; GAS-CHROMATOGRAPHY; MICROEXTRACTION; ADSORPTION; PESTICIDES; ADSORBENT; PRECONCENTRATION;
D O I
10.1016/j.talanta.2015.02.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three metal-organic frameworks (MOFs), specifically HKUST-1, MOF-5, and MIL-53(AI), have been synthetized, characterized, studied and compared in a vortex-assisted dispersive micro-solid-phase extraction (VA-D-mu-SPE) procedure in combination with high-performance liquid chromatography (HPLC) with diode-array detection (DAD) for determining seven parabens in environmental waters (tap water, swimming pool water, and water coming from a spa pool), human urine (from two volunteers), and cosmetic creams (two commercial brands). Experimental parameters, such as nature and amount of MOF, sample volume, nature of elution solvent and its amount, vortex and centrifugation time, among others, were properly optimized. HKUST-1 was the most adequate MOF to work with. Detection limits for the overall method down to 0.1 mu g L-1 for butylparaben (BPB) and benzylparaben (BzPB) were obtained, with determination coefficients (R-2) higher than 0.9966 for a range of 0.5-147 mu g L-1 (depending on the paraben), average relative recoveries (RR, in %) of 803% at the low spiked level (7 mu g L-1), and relative standard deviation (RSD) values below 10% also at the low spiked level. The strength of the affinity between HKUST-1 and parabens was evaluated, and it ranged from 33.5% for isopropylparaben (iPPB) to 77.0% for isobutylparaben (iBPB). When analyzing complex environmental waters, RR values of 78%, inter-day precision values (as RSD) lower than 15%, and intra-day precision values lower than 7.8% were obtained, despite the observed matrix effect. When analyzing cosmetic creams, parabens were detected, with contents ranging from 0.14 +/- 0.01 mu g g(-1) for EPB in the healing cream analyzed to 1.12 +/- 0.07 mg g(-1) for MPB in the mask cream analyzed, with precision values (RSD) lower than 12% and RR values from 63.7% for propylparaben (PPB) to 121% for iPPB. When analyzing human urine, no parabens were detected but the method could be performed with RSD values lower than 19%. These results show the adequateness of MOFs as sorbents in VA-D-mu-SPE procedures despite sample complexity. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [21] UiO-66-based metal-organic framework for dispersive solid-phase extraction of vanillylmandelic acid from urine before analysis by capillary electrophoresis
    Hassanpour-Sabet, Roghayeh
    Seyfinejad, Behruoz
    Khosrowshahi, Elnaz Marzi
    Nemati, Mahboob
    Mogaddam, Mohammad Reza Afshar
    Jouyban, Abolghasem
    RSC ADVANCES, 2022, 12 (44) : 28728 - 28737
  • [22] Dimethyldioctadecylanimonium bentonite immobilized magnetic chitosan nanoparticles as an efficient adsorbent for vortex-assisted magnetic dispersive micro-solid-phase extraction of celecoxib from human breast milk, plasma and urine samples
    Majidi, Seyedeh Maedeh
    Hadjmohammadi, Mohammad Reza
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (09)
  • [23] Porous carbon derived from a metal-organic framework as an efficient adsorbent for the solid-phase extraction of phthalate esters
    Liu, Xingli
    Wang, Chun
    Wu, Qiuhua
    Wang, Zhi
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (22) : 3928 - 3935
  • [24] Synthesis of an ordered macroporous metal-organic framework for efficient solid-phase extraction of aflatoxins from milk products
    Li, Xuemei
    Zhang, Lidan
    Yang, Mingzhu
    Wang, Rongyu
    Zong, Shaojun
    Ning, Xiaobei
    Lv, Yingchao
    Wang, Xiao
    Ji, Wenhua
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1713
  • [25] Magnetic porous carbon derived from a metal-organic framework as a magnetic solid-phase extraction adsorbent for the extraction of sex hormones from water and human urine
    Ma, Ruiyang
    Hao, Lin
    Wang, Junmin
    Wang, Chun
    Wu, Qiuhua
    Wang, Zhi
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (18) : 3571 - 3577
  • [26] The metal-organic framework MIL-101(Cr) as efficient adsorbent in a vortex-assisted dispersive solid-phase extraction of imatinib mesylate in rat plasma coupled with ultra-performance liquid chromatography/mass spectrometry: Application to a pharmacokinetic study
    Qi, Chao
    Cai, Qianqian
    Zhao, Pan
    Jia, Xiuna
    Lu, Nan
    He, Lu
    Hou, Xiaohong
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1449 : 30 - 38
  • [27] A cadmium(II)-based metal-organic framework material for the dispersive solid-phase extraction of polybrominated diphenyl ethers in environmental water samples
    Su, Hao
    Wang, Ze
    Jia, Yuqian
    Deng, Liulin
    Chen, Xiangfeng
    Zhao, Rusong
    Chan, T. -W. Dominic
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1422 : 334 - 339
  • [28] Vortex-assisted solid-phase extraction based on metal-organic framework/chitosan-functionalized hydrophilic sponge column for determination of triazine herbicides in environmental water by liquid chromatography-tandem mass spectrometry
    Jiang, Yanxiao
    Qin, Zucheng
    Liang, Fanghui
    Li, Jingkang
    Sun, Ying
    Wang, Xinghua
    Ma, Pinyi
    Song, Daqian
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1638
  • [29] A magnetic-based dispersive micro-solid-phase extraction method using the metal-organic framework HKUST-1 and ultra-high-performance liquid chromatography with fluorescence detection for determining polycyclic aromatic hydrocarbons in waters and fruit tea infusions
    Rocio-Bautista, Priscilla
    Pino, Veronica
    Ayala, Juan H.
    Pasan, Jorge
    Ruiz-Perez, Catalina
    Afonso, Ana M.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1436 : 42 - 50
  • [30] Fiber coating based on a green metal-organic framework to determine phthalates in bottled waters by direct-immersion micro solid-phase extraction
    Rascon, Andres J.
    Rocio-Bautista, Priscilla
    Moreno-Gonzalez, David
    Garcia-Reyes, Juan F.
    Ballesteros, Evaristo
    MICROCHEMICAL JOURNAL, 2023, 191