Influence of the water jet system vs cavitron ultrasonic surgical aspirator for liver resection on the remnant liver

被引:6
|
作者
Hanaki, Takehiko [1 ,2 ]
Tsuda, Ayumi [1 ]
Sunaguchi, Teppei [1 ]
Goto, Keisuke [1 ]
Morimoto, Masaki [1 ]
Murakami, Yuki [1 ]
Kihara, Kyoichi [1 ]
Matsunaga, Tomoyuki [1 ]
Yamamoto, Manabu [1 ]
Tokuyasu, Naruo [1 ]
Sakamoto, Teruhisa [1 ]
Hasegawa, Toshimichi [1 ]
Fujiwara, Yoshiyuki [1 ]
机构
[1] Tottori Univ, Dept Surg, Div Gastrointestinal & Pediat Surg, Fac Med, Yonago, Tottori 6838504, Japan
[2] Tottori Univ, Dept Surg, Div Gastrointestinal & Pediat Surg, Fac Med, 36-1 Nishi Cho, Yonago, Tottori 6838504, Japan
关键词
Water jet; Cavitron ultrasonic surgical aspirator; Energy device; Hepatic parenchymal dissection; Liver resection;
D O I
10.12998/wjcc.v10.i20.6855
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Several methods, such as finger fracture, Pean crush, cavitron ultrasonic surgical aspirator (CUSA), and water jet (WJ), are used for hepatic parenchymal dissection in liver surgery. CUSA is the conventional method in Japan. WJ is a relatively novel method for parenchymal dissection. Although it has several advantages, such as lower volume of blood loss and shorter operative time, the effect of the WJ system for hepatic dissection on the remnant liver has not yet been investigated. AIM To investigate and compare the effect of the WJ method vs CUSA on the remnant liver cut surface. METHODS This observational study compared the two types of parenchymal transection methods (WJ vs CUSA) in liver surgery. In total, 24 and 40 patients who underwent hepatectomy using the WJ method and CUSA, respectively, were included in the analysis. Accordingly, the clinicopathological characteristics and clinical outcomes of 24 and 40 patients were compared. Furthermore, postoperative contrast-enhanced computed tomography (CT) scan was performed to assess the cut surface length of the remnant liver and the degenerative thickness of the areas with a reduced contrast effect in the dissected plane. Then, the two groups were compared. RESULTS On CT scan, the median areas of denaturation in the liver dissection planes were 522 (range: 109.5-1242) mm(2) in the CUSA group and 324 (range: 93.6-1529) mm(2) in the WJ group. The area did not significantly differ between the two groups; however, the denaturation thickness of the WJ group was significantly lower than that of the CUSA group [5.8 (range: 0.7-11.1) mm vs 3.3 (range: 1.7-10.4) mm, P < 0.001]. CONCLUSION The WJ group had significantly thinner contrast-enhanced areas in the post hepatectomy detached section than the CUSA group.
引用
收藏
页码:6855 / 6864
页数:10
相关论文
共 50 条
  • [21] New Simple Technique for Hepatic Parenchymal Resection Using a Cavitron Ultrasonic Surgical Aspirator® and Bipolar Cautery Equipped with a Channel for Water Dripping
    Yuzo Yamamoto
    Iwao Ikai
    Makoto Kume
    Yoshiharu Sakai
    Akira Yamauchi
    Hisashi Shinohara
    Taisuke Morimoto
    Yasuyuki Shimahara
    Masayuki Yamamoto
    Yoshio Yamaoka
    World Journal of Surgery, 1999, 23 : 1032 - 1037
  • [22] RESECTION OF THE LIVER WITH A WATER JET
    PAPACHRISTOU, DN
    BARTERS, R
    BRITISH JOURNAL OF SURGERY, 1982, 69 (02) : 93 - 94
  • [23] LIVER RESECTION - A COMPARISON USING THE ND-YAG LASER, AN ULTRASONIC SURGICAL ASPIRATOR, OR BLUNT DISSECTION
    TRANBERG, KG
    RIGOTTI, P
    BRACKETT, KA
    BJORNSON, HS
    FISCHER, JE
    JOFFE, SN
    AMERICAN JOURNAL OF SURGERY, 1986, 151 (03): : 368 - 373
  • [24] CYTO-PATHOLOGY OF CENTRAL NERVOUS-SYSTEM TISSUE OBTAINED BY CAVITRON ULTRASONIC SURGICAL ASPIRATOR
    SILVERMAN, JF
    JONES, D
    UNVERFERTH, M
    BERNS, L
    ACTA CYTOLOGICA, 1988, 32 (05) : 780 - 781
  • [25] POSTRESECTION CHANGES IN LIVER MORPHOLOGY MONITORED BY THE SOVIET SURGICAL ULTRASONIC ASPIRATOR
    SAVVINA, TV
    VISHNEVSKII, VA
    IKRAMOV, RZ
    ABULKHANOV, AR
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1991, 111 (03) : 393 - 396
  • [26] LIVER RESECTION USING A WATER JET
    UNE, Y
    UCHINO, J
    HORIE, T
    SATO, Y
    OGASAWARA, K
    KAKITA, A
    SANO, F
    CANCER CHEMOTHERAPY AND PHARMACOLOGY, 1989, 23 : S74 - S77
  • [27] A MORPHOLOGICAL-STUDY OF THE EFFECT OF THE CAVITRON ULTRASONIC SURGICAL ASPIRATOR SYSTEM NEAR HUMAN PERIPHERAL-NERVES
    GLEESON, MJ
    FISCH, U
    FELIX, H
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1987, 113 (05) : 530 - 532
  • [28] CYTO-PATHOLOGY OF NEOPLASMS OF THE CENTRAL NERVOUS-SYSTEM IN SPECIMENS OBTAINED BY THE CAVITRON ULTRASONIC SURGICAL ASPIRATOR
    SILVERMAN, JF
    JONES, FD
    UNVERFERTH, M
    BERNS, L
    ACTA CYTOLOGICA, 1989, 33 (05) : 576 - 582
  • [29] Comparison of liver parenchymal ablation and tissue necrosis in a cadaveric bovine model using the Harmonic Scalpel™, the LigaSure™, the Cavitron Ultrasonic Surgical Aspirator® and the Aquamantys® devices
    S. Hammond, John
    Muirhead, William
    Zaitoun, Abed M.
    Cameron, Iain C.
    Lobo, Dileep N.
    HPB, 2012, 14 (12) : 828 - 832
  • [30] Comparison of liver parenchymal ablation, tissue necrosis and lateral thermal spread using the harmonic scalpel™, the ligasure™, the cavitron ultrasonic surgical aspirator and the tissuelink™ dissector
    Hammond, J. S.
    Muirhead, W.
    Cameron, I.
    Perkins, A. C.
    Zaitoun, A.
    Lobo, D. N.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 31 - 31