Comparison of liver parenchymal ablation and tissue necrosis in a cadaveric bovine model using the Harmonic Scalpel™, the LigaSure™, the Cavitron Ultrasonic Surgical Aspirator® and the Aquamantys® devices

被引:28
|
作者
S. Hammond, John [1 ]
Muirhead, William [1 ]
Zaitoun, Abed M. [2 ]
Cameron, Iain C. [1 ]
Lobo, Dileep N. [1 ]
机构
[1] Univ Nottingham Hosp, Queens Med Ctr, Natl Inst Hlth Res,Biomed Res Unit, Div Gastrointestinal Surg,Nottingham Digest Dis C, Nottingham NG7 2UH, England
[2] Univ Nottingham Hosp, Queens Med Ctr, Natl Inst Hlth Res,Biomed Res Unit, Dept Cellular Pathol,Nottingham Digest Dis Ctr, Nottingham NG7 2UH, England
关键词
RADIOFREQUENCY DISSECTING SEALER; HEPATIC RESECTION; COLORECTAL-CANCER; SURGERY; MARGIN; METASTASES; TRANSECTION; HEPATECTOMY; RECURRENCE; EXPERIENCE;
D O I
10.1111/j.1477-2574.2012.00547.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives The amount of tissue that is ablated or necrosed at the line of parenchymal transection is of clinical significance in the interpretation of resection margin status following hepatic resection. The aim of this study was to define the extent of parenchymal ablation and necrosis in liver tissue using the Harmonic Scalpel (TM), the LigaSure (TM), the Cavitron Ultrasonic Surgical Aspirator (R) (CUSA (R)) and the Aquamantys (R) dissector ex vivo. Methods Mounted blocks of non-perfused bovine liver were transected using the Harmonic Scalpel (TM), LigaSure (TM), CUSA (R) and Aquamantys (R) devices. Outcome measures included parenchymal ablation (ablation band widths and weights) and tissue necrosis band widths along the line of transection. Each experiment was replicated five times. Results All devices were associated with parenchymal ablation (Harmonic Scalpel (TM), 4.73?+/-?1.62?mm; LigaSure (TM), 4.55?+/-?2.02?mm; CUSA (R), 7.16?+/-?2.87?mm; Aquamantys (R), 4.75?+/-?1.43?mm) and tissue necrosis (Harmonic Scalpel (TM), 1.07?+/-?0.46?mm; LigaSure (TM), 1.36?+/-?0.36?mm; CUSA (R), 0.81?+/-?0.21?mm; Aquamantys (R), 0.81?+/-?0.36?mm). Conclusions The Harmonic Scalpel (TM), LigaSure (TM), CUSA (R) and Aquamantys (R) devices were associated with bands of tissue loss along the hepatic parenchymal transection line in this benchtop cadaveric model. This should be taken into account in the interpretation of resection margin status following liver resection.
引用
收藏
页码:828 / 832
页数:5
相关论文
共 4 条
  • [1] Comparison of liver parenchymal ablation, tissue necrosis and lateral thermal spread using the harmonic scalpel™, the ligasure™, the cavitron ultrasonic surgical aspirator and the tissuelink™ dissector
    Hammond, J. S.
    Muirhead, W.
    Cameron, I.
    Perkins, A. C.
    Zaitoun, A.
    Lobo, D. N.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 31 - 31
  • [2] Liver resection using cavitron ultrasonic surgical aspirator (CUSA) versus harmonic scalpel: A retrospective cohort study
    Bodzin, Adam S.
    Leiby, Benjamin E.
    Ramirez, Carlo G.
    Frank, Adam M.
    Doria, Cataldo
    INTERNATIONAL JOURNAL OF SURGERY, 2014, 12 (05) : 500 - 503
  • [3] Randomized, comparative study between using harmonic scalpel with monopolar cautery versus cavitron ultrasonic surgical aspirator with bipolar cautery in liver resection
    Naga, Mohamed A.
    Sayed, Hatem
    EGYPTIAN JOURNAL OF SURGERY, 2019, 38 (01): : 87 - 94
  • [4] A Multicenter, Open-Label, Single-Arm Phase I Trial of Dual-Wield Parenchymal Transection: A New Technique of Liver Resection Using the Cavitron Ultrasonic Surgical Aspirator and Water- Jet Scalpel Simultaneously (HiSCO-14 Trial)
    Oshita, Ko
    Kuroda, Shintaro
    Kobayashi, Tsuyoshi
    Aoki, Gaku
    Mashima, Hiroaki
    Onoe, Takashi
    Shigemoto, Norifumi
    Hirata, Taizo
    Tashiro, Hirotaka
    Ohdan, Hideki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)