New Simple Technique for Hepatic Parenchymal Resection Using a Cavitron Ultrasonic Surgical Aspirator® and Bipolar Cautery Equipped with a Channel for Water Dripping

被引:0
|
作者
Yuzo Yamamoto
Iwao Ikai
Makoto Kume
Yoshiharu Sakai
Akira Yamauchi
Hisashi Shinohara
Taisuke Morimoto
Yasuyuki Shimahara
Masayuki Yamamoto
Yoshio Yamaoka
机构
[1] Department of Gastroenterological Surgery,
[2] Kyoto University,undefined
[3] Graduate School of Medicine,undefined
[4] 54 Kawahara-cho,undefined
[5] Shogoin,undefined
[6] Sakyo-ku,undefined
[7] Kyoto 606-8507,undefined
[8] Japan,undefined
来源
World Journal of Surgery | 1999年 / 23卷
关键词
Inferior Vena Cava; Hepatic Vein; Remnant Liver; Major Hepatectomy; Hepatic Coma;
D O I
暂无
中图分类号
学科分类号
摘要
We have developed a new technique to resect hepatic parenchyma without inflow occlusion by using the Cavitron Ultrasonic Surgical Aspirator (CUSA®) and bipolar cautery with a saline irrigation system. The significance of this method in hepatectomy was analyzed in comparison with historical control of hepatectomy using Pringle's maneuver. An ordinary bipolar cautery was remodeled with an infusion line to bring saline droplets down the inner surface of one arm of the tweezers through an opening about 1.5 cm proximal to its tip. The optimal flow rate of saline was approximately one drop per second. The power of bipolar cautery was adjusted to 50 watts. When the tweezer blades were approximated to 1 or 2 mm, saline droplets were directed to the tip of tweezers and could be immediately evaporated. After sonicating parenchymal cells, the tissue of small branches of Glisson's tree or small tributaries of the hepatic vein were coagulated by bipolar cautery. The coagulated cords were then easily cut by scissors. The impact of this technique on ordinary liver resections was evaluated by analyzing the postoperative clinical course in relation to the hepatic functional reserve necessary for major hepatectomy, duration of hepatectomy, and intraoperative blood loss. Hepatic resection without vascular occlusion using this technique could decrease the morbidity in patients who have less hepatic functional reserve. It could also decrease intraoperative blood loss. This new technique effectively decreased the surgical load of the remnant liver during parenchymal resection by avoiding ischemic stress. Consequently it extends the safety limits of major hepatectomy.
引用
收藏
页码:1032 / 1037
页数:5
相关论文
共 23 条
  • [1] New simple technique for hepatic parenchymal resection using a cavitron ultrasonic surgical aspirators and bipolar cautery equipped with a channel for water dripping
    Yamamoto, Y
    Ikai, I
    Kume, M
    Sakai, Y
    Yamauchi, A
    Shinohara, H
    Morimoto, T
    Shimahara, Y
    Yamamoto, M
    Yamaoka, Y
    WORLD JOURNAL OF SURGERY, 1999, 23 (10) : 1032 - 1037
  • [2] Randomized, comparative study between using harmonic scalpel with monopolar cautery versus cavitron ultrasonic surgical aspirator with bipolar cautery in liver resection
    Naga, Mohamed A.
    Sayed, Hatem
    EGYPTIAN JOURNAL OF SURGERY, 2019, 38 (01): : 87 - 94
  • [3] Two Different Methods for Donor Hepatic Transection: Cavitron Ultrasonic Surgical Aspirator with Bipolar Cautery Versus Cavitron Ultrasonic Surgical Aspirator with Radiofrequency Coagulator-A Randomized Controlled Trial
    El Moghazy, Walid M.
    Hedaya, Mohammed S.
    Kaido, Toshimi
    Egawa, Hiroto
    Uemoto, Shinji
    Takada, Yasutsugu
    LIVER TRANSPLANTATION, 2009, 15 (01) : 102 - 105
  • [4] Hepatic parenchymal resection using an ultrasonic surgical aspirator with electrosurgical coagulation
    Taniai, N
    Onda, M
    Tajiri, T
    Akimaru, K
    Yoshida, H
    Mamada, Y
    HEPATO-GASTROENTEROLOGY, 2002, 49 (48) : 1649 - 1651
  • [5] Resection of Pediatric Malignant Tumors Using the Cavitron Ultrasonic Surgical Aspirator
    Tanaka, Hideaki
    Goto, Yudai
    Shimizu, Hirofumi
    Yamashita, Michitoshi
    Sano, Hideki
    Kikuta, Atsushi
    PEDIATRIC BLOOD & CANCER, 2018, 65 : S72 - S72
  • [6] Cardiac arrest by venous air embolism during hepatic resection using the Cavitron Ultrasonic Surgical Aspirator®
    Adachi, Yushi U.
    Doi, Matsuyuki
    Sato, Shigehito
    ANESTHESIA AND ANALGESIA, 2006, 103 (02): : 493 - 494
  • [7] Hepatic resection using ultrasonic surgical aspirator
    Sriussadaporn, Suvit
    Sriussadaporn, Sukanya
    Pak-art, Rattaplee
    Kritayakirana, Kritaya
    Prichayudh, Supparerk
    Samorn, Pasurachate
    ASIAN BIOMEDICINE, 2015, 9 (02) : 175 - 183
  • [8] Cardiac arrest by venous air embolism during hepatic resection using the Cavitron Ultrasonic Surgical Aspirator® -: Response
    Koo, Bon-N.
    Kim, Ji Y.
    Kil, Hae K.
    Hong, Yong W.
    ANESTHESIA AND ANALGESIA, 2006, 103 (02): : 494 - 494
  • [9] Hepatic resection by the Cavitron Ultrasonic Surgical Aspirator® increases the incidence and severity of venous air embolism
    Koo, BN
    Kil, HK
    Choi, JS
    Kim, JY
    Chun, DH
    Hong, YW
    ANESTHESIA AND ANALGESIA, 2005, 101 (04): : 966 - 970
  • [10] Influence of the water jet system vs cavitron ultrasonic surgical aspirator for liver resection on the remnant liver
    Hanaki, Takehiko
    Tsuda, Ayumi
    Sunaguchi, Teppei
    Goto, Keisuke
    Morimoto, Masaki
    Murakami, Yuki
    Kihara, Kyoichi
    Matsunaga, Tomoyuki
    Yamamoto, Manabu
    Tokuyasu, Naruo
    Sakamoto, Teruhisa
    Hasegawa, Toshimichi
    Fujiwara, Yoshiyuki
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (20) : 6855 - 6864