4-D Intracardiac Ultrasound Vector Flow Imaging-Feasibility and Comparison to Phase-Contrast MRI

被引:55
|
作者
Wigen, Morten Smedsrud [1 ]
Fadnes, Solveig [1 ]
Rodriguez-Molares, Alfonso [1 ]
Bjastad, Tore [1 ,2 ]
Eriksen, Marius [3 ]
Stensaeth, Knut Haakon [1 ,3 ]
Stoylen, Asbjorn [1 ]
Lovstakken, Lasse [1 ]
机构
[1] NTNU, Dept Circulat & Med Imaging, N-7491 Trondheim, Norway
[2] GE Vingmed, N-3183 Horten, Norway
[3] St Olavs Hosp, Dept Radiol & Nucl Med, N-7006 Trondheim, Norway
关键词
Blood flow imaging; intracardiac flow imaging; plane wave imaging; vector flow imaging; 4D ultrasound; VELOCITY ESTIMATION; MOTION ESTIMATION; TISSUE DOPPLER; B-MODE;
D O I
10.1109/TMI.2018.2844552
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In vivo characterization of intracardiac blood velocity vector fields may provide new clinical information but is currently not available for bedside evaluation. In this paper, 4-D vector flow imaging for intracardiac flow assessment is demonstrated using a clinical ultrasound (US) system and a matrix array transducer, without the use of contrast agent. Two acquisition schemes were developed, one for full volumetric coverage of the left ventricle (LA) at 50 vps and a 3-D thick-slice setup with continuous frame acquisition (4000 vps), both utilizing ECG-gating. The 3-D vector velocity estimates were obtained using a novel method combining phase and envelope information. In vitro validation in a rotating tissue-mimicking phantom revealed velocity estimates in compliance with the ground truth, with a linear regression slope of 0.80, 0.77, and 1.03 for the x, y, and z velocity components, and with standard deviations of 2.53, 3.19, and 0.95 cm/s, respectively. In vivo measurements in a healthy LV showed good agreement with PC-MRI. Quantitative analysis of energy loss (EL) and kinetic energy (KE) further showed similar trends, with peak KE at 1.5 and 2.4 mJ during systole and 3.6 and 3.1 mJ for diastole for US and PC-MRI. Similar for EL, 0.15-0.2 and 0.7 mW was found during systole and 0.6 and 0.7 mW during diastole, for US and PC-MRI, respectively. Overall, a potential for US as a future modality for 4D cardiac vector flow imaging was demonstrated, which will be further evaluated in clinical studies.
引用
收藏
页码:2619 / 2629
页数:11
相关论文
共 50 条
  • [31] 4-D Spatiotemporal Analysis of Ultrasound Contrast Agent Dispersion for Prostate Cancer Localization: A Feasibility Study
    Schalk, Stefan G.
    Demi, Libertario
    Smeenge, Martijn
    Mills, David M.
    Wallace, Kirk D.
    de la Rosette, Jean J. M. C. H.
    Wijkstra, Hessel
    Mischi, Massimo
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (05) : 839 - 851
  • [32] Accelerated Phase-Contrast MR Imaging: Comparison of k-t BLAST With SENSE and Doppler Ultrasound for Velocity and Flow Measurements in the Aorta
    Stadlbauer, Andreas
    van der Riet, Wilma
    Globits, Sebastian
    Crelier, Gerard
    Salomonowitz, Erich
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (04) : 817 - 824
  • [33] Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study
    Bjoern P. Schoennagel
    Chressen C. Remus
    Jin Yamamura
    Fabian Kording
    Manuela Tavares de Sousa
    Kurt Hecher
    Roland Fischer
    Friedrich Ueberle
    Matthias Boehme
    Gerhard Adam
    Hendrik Kooijman
    Ulrike Wedegaertner
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 237 - 244
  • [34] Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study
    Schoennagel, Bjoern P.
    Remus, Chressen C.
    Yamamura, Jin
    Kording, Fabian
    de Sousa, Manuela Tavares
    Hecher, Kurt
    Fischer, Roland
    Ueberle, Friedrich
    Boehme, Matthias
    Adam, Gerhard
    Kooijman, Hendrik
    Wedegaertner, Ulrike
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (03) : 237 - 244
  • [35] Carotid Phase-Contrast Magnetic Resonance before Treatment: 4D-Flow versus Standard 2D Imaging
    Secchi, Francesco
    Monti, Caterina Beatrice
    Capra, Davide
    Vitale, Renato
    Mazzaccaro, Daniela
    Conti, Michele
    Jin, Ning
    Giese, Daniel
    Nano, Giovanni
    Sardanelli, Francesco
    Marrocco-Trischitta, Massimiliano M.
    TOMOGRAPHY, 2021, 7 (04) : 513 - 522
  • [36] Prospective evaluation of 4-D contrast-enhanced-ultrasound (CEUS) imaging in bladder tumors
    Jokisch, F.
    Buchner, A.
    Schulz, G. B.
    Grimm, T.
    Weinhold, P.
    Pfitzinger, P. L.
    Chaloupka, M.
    Stief, C. G.
    Schlenker, B.
    Clevert, D-A
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 74 (01) : 1 - 12
  • [37] Flow visualization of recurrent aneurysms after coil embolization by 3D phase-contrast MRI
    Kono, Kenichi
    Terada, Tomoaki
    ACTA NEUROCHIRURGICA, 2014, 156 (11) : 2035 - 2040
  • [38] Flow visualization of recurrent aneurysms after coil embolization by 3D phase-contrast MRI
    Kenichi Kono
    Tomoaki Terada
    Acta Neurochirurgica, 2014, 156 : 2035 - 2040
  • [39] Comparison of Four-Dimensional Flow MRI, Two-Dimensional Phase-Contrast MRI and Echocardiography in Transposition of the Great Arteries
    Warmerdam, Evangeline G. G.
    Westenberg, Jos J. M.
    Voskuil, Michiel
    Rijnberg, Friso M. M.
    Roest, Arno A. W.
    Lamb, Hildo J. J.
    van Wijk, Bram
    Sieswerda, Gertjan T. T.
    Doevendans, Pieter A. A.
    ter Heide, Henriette
    Krings, Gregor J. J.
    Leiner, Tim
    Grotenhuis, Heynric B. B.
    PEDIATRIC CARDIOLOGY, 2024, 45 (08) : 1627 - 1635
  • [40] Blood-flow volume quantification in internal carotid and vertebral arteries:: Comparison of 3 different ultrasound techniques with phase-contrast MR imaging\
    Oktar, SO
    Yücel, C
    Karaosmanoglu, D
    Akkan, K
    Ozdemir, H
    Tokgoz, N
    Tali, T
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (02) : 363 - 369