Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study

被引:19
|
作者
Schoennagel, Bjoern P. [1 ]
Remus, Chressen C. [1 ]
Yamamura, Jin [1 ]
Kording, Fabian [1 ]
de Sousa, Manuela Tavares [2 ]
Hecher, Kurt [2 ]
Fischer, Roland [3 ,4 ]
Ueberle, Friedrich [5 ]
Boehme, Matthias [1 ]
Adam, Gerhard [1 ]
Kooijman, Hendrik [6 ]
Wedegaertner, Ulrike [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Obstet & Fetal Med, D-20246 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Pediat Hematol & Oncol, D-20246 Hamburg, Germany
[4] Childrens Hosp & Res Ctr Oakland, Oakland, CA USA
[5] Hamburg Univ Appl Sci, Hamburg, Germany
[6] Philips Med Syst, Hamburg, Germany
关键词
Magnetic resonance imaging; Cardiac triggering; Fetal blood flow; Flow velocimetry; Fetal sheep; INTRAUTERINE GROWTH RESTRICTION; PRENATAL-DIAGNOSIS; DESCENDING AORTA; VENOUS DOPPLER; ANIMAL-MODEL; VELOCITY; VALIDATION; ARTERY; QUANTIFICATION; CIRCULATION;
D O I
10.1007/s10334-013-0397-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present the first study demonstrating the feasibility of antenatal blood flow velocimetry performing ECG triggered phase-contrast (PC)-MRI in the fetal aorta by using a newly developed Doppler ultrasound trigger. Five pregnant sheep carrying singleton fetuses (gestational age 121 days) were anesthetized to undergo fetal 2D PC-MRI in the fetal descending aorta (1.5 T) using a newly developed MR-compatible Doppler ultrasound trigger for fetal cardiac triggering. Inter-operator variability was assessed for PC-MR measurements and reproducibility was tested by repeated scans in one fetus. Inter-modality comparison was performed by Doppler ultrasound velocimetry. Fetal cardiac triggering was possible in all examinations. PC-MR velocimetry revealed a mean inter-operator variability of 3 +/- A 5 %. Average peak systolic flow velocities of 62.5 +/- A 4.4 cm/s were in good agreement with Doppler ultrasound measurements of 62.0 +/- A 9.2 cm/s (p (Lord's U test) a parts per thousand << 0.05). Fetal PC-MR velocimetry was successfully performed using the newly developed MR-compatible Doppler ultrasound trigger for intrauterine fetal cardiac triggering, demonstrating high inter-operator and inter-modality agreement. This new method has the high potential for alternative assessment of hemodynamic decompensation of the fetal circulation.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [1] Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study
    Bjoern P. Schoennagel
    Chressen C. Remus
    Jin Yamamura
    Fabian Kording
    Manuela Tavares de Sousa
    Kurt Hecher
    Roland Fischer
    Friedrich Ueberle
    Matthias Boehme
    Gerhard Adam
    Hendrik Kooijman
    Ulrike Wedegaertner
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 237 - 244
  • [2] Erratum to: Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study
    Bjoern P. Schoennagel
    Chressen C. Remus
    Jin Yamamura
    Fabian Kording
    Manuela Tavares de Sousa
    Kurt Hecher
    Roland Fischer
    Friedrich Ueberle
    Matthias Boehme
    Gerhard Adam
    Hendrik Kooijman
    Ulrike Wedegaertner
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 463 - 463
  • [3] Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study (vol 27, pg 237, 2014)
    Schoennagel, Bjoern P.
    Remus, Chressen C.
    Yamamura, Jin
    Kording, Fabian
    de Sousa, Manuela Tavares
    Hecher, Kurt
    Fischer, Roland
    Ueberle, Friedrich
    Boehme, Matthias
    Adam, Gerhard
    Kooijman, Hendrik
    Wedegaertner, Ulrike
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (05) : 463 - 463
  • [4] Fetal dynamic phase-contrast MR angiography using ultrasound gating and comparison with Doppler ultrasound measurements
    B. P. Schoennagel
    J. Yamamura
    F. Kording
    R. Fischer
    P. Bannas
    G. Adam
    H. Kooijman
    C. Ruprecht
    K. Fehrs
    M. Tavares de Sousa
    European Radiology, 2019, 29 : 4169 - 4176
  • [5] Fetal dynamic phase-contrast MR angiography using ultrasound gating and comparison with Doppler ultrasound measurements
    Schoennagel, B. P.
    Yamamura, J.
    Kording, F.
    Fischer, R.
    Bannas, P.
    Adam, G.
    Kooijman, H.
    Ruprecht, C.
    Fehrs, K.
    de Sousa, M. Tavares
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4169 - 4176
  • [6] Comparison of hemodialysis arteriovenous fistula blood flow rates measured by Doppler ultrasound and phase-contrast magnetic resonance imaging
    He, Yong
    Shiu, Yan-Ting
    Pike, Daniel B.
    Roy-Chaudhury, Prabir
    Cheung, Alfred K.
    Berceli, Scott A.
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (06) : 1848 - +
  • [7] Assessment of cerebral blood flow in neonates and infants: A phase-contrast MRI study
    Liu, Peiying
    Qi, Ying
    Lin, Zixuan
    Guo, Qiyong
    Wang, Xiaoming
    Lu, Hanzhang
    NEUROIMAGE, 2019, 185 : 926 - 933
  • [8] MEASUREMENT OF FETAL BLOOD-FLOW USING THE DOPPLER ULTRASOUND METHOD
    ERIKSEN, PS
    RASMUSSEN, K
    THORUP, E
    JOURNAL OF PERINATAL MEDICINE, 1984, 12 (05) : 254 - 256
  • [9] Quantification of blood flow in the carotid arteries -: Comparison of Doppler ultrasound and three different phase-contrast magnetic resonance imaging sequences
    Seitz, J
    Strotzer, M
    Wild, T
    Nitz, WR
    Völk, M
    Lenhart, M
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 2001, 36 (11) : 642 - 647
  • [10] Comparison of blood velocity measurements between ultrasound Doppler and accelerated phase-contrast MR angiography in small arteries with disturbed flow
    Jiang, Jingfeng
    Strother, Charles
    Johnson, Kevin
    Baker, Sara
    Consigny, Dan
    Wieben, Oliver
    Zagzebski, James
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06): : 1755 - 1773