4-D Intracardiac Ultrasound Vector Flow Imaging-Feasibility and Comparison to Phase-Contrast MRI

被引:55
|
作者
Wigen, Morten Smedsrud [1 ]
Fadnes, Solveig [1 ]
Rodriguez-Molares, Alfonso [1 ]
Bjastad, Tore [1 ,2 ]
Eriksen, Marius [3 ]
Stensaeth, Knut Haakon [1 ,3 ]
Stoylen, Asbjorn [1 ]
Lovstakken, Lasse [1 ]
机构
[1] NTNU, Dept Circulat & Med Imaging, N-7491 Trondheim, Norway
[2] GE Vingmed, N-3183 Horten, Norway
[3] St Olavs Hosp, Dept Radiol & Nucl Med, N-7006 Trondheim, Norway
关键词
Blood flow imaging; intracardiac flow imaging; plane wave imaging; vector flow imaging; 4D ultrasound; VELOCITY ESTIMATION; MOTION ESTIMATION; TISSUE DOPPLER; B-MODE;
D O I
10.1109/TMI.2018.2844552
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In vivo characterization of intracardiac blood velocity vector fields may provide new clinical information but is currently not available for bedside evaluation. In this paper, 4-D vector flow imaging for intracardiac flow assessment is demonstrated using a clinical ultrasound (US) system and a matrix array transducer, without the use of contrast agent. Two acquisition schemes were developed, one for full volumetric coverage of the left ventricle (LA) at 50 vps and a 3-D thick-slice setup with continuous frame acquisition (4000 vps), both utilizing ECG-gating. The 3-D vector velocity estimates were obtained using a novel method combining phase and envelope information. In vitro validation in a rotating tissue-mimicking phantom revealed velocity estimates in compliance with the ground truth, with a linear regression slope of 0.80, 0.77, and 1.03 for the x, y, and z velocity components, and with standard deviations of 2.53, 3.19, and 0.95 cm/s, respectively. In vivo measurements in a healthy LV showed good agreement with PC-MRI. Quantitative analysis of energy loss (EL) and kinetic energy (KE) further showed similar trends, with peak KE at 1.5 and 2.4 mJ during systole and 3.6 and 3.1 mJ for diastole for US and PC-MRI. Similar for EL, 0.15-0.2 and 0.7 mW was found during systole and 0.6 and 0.7 mW during diastole, for US and PC-MRI, respectively. Overall, a potential for US as a future modality for 4D cardiac vector flow imaging was demonstrated, which will be further evaluated in clinical studies.
引用
收藏
页码:2619 / 2629
页数:11
相关论文
共 50 条
  • [21] Comparison of 4D Phase-Contrast MRI Flow Measurements to Computational Fluid Dynamics Simulations of Cerebrospinal Fluid Motion in the Cervical Spine
    Yiallourou, Theresia I.
    Kroeger, Jan Robert
    Stergiopulos, Nikolaos
    Maintz, David
    Martin, Bryn A.
    Bunck, Alexander C.
    PLOS ONE, 2012, 7 (12):
  • [22] Assessment of fluctuating velocities in disturbed cardiovascular blood flow: In vivo feasibility of generalized phase-contrast MRI
    Dyverfeldt, Petter
    Kvitting, John-Peder Escobar
    Sigfridsson, Andreas
    Engvall, Jan
    Bolger, Ann F.
    Ebbers, Tino
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) : 655 - 663
  • [23] Repeatability and reliability of 2D phase-contrast and 4D flow MRI when measuring cerebral pulsatility
    Morgan, A.
    Thrippleton, M.
    Stringer, M.
    Jin, N.
    Wardlaw, J.
    Marshall, I.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2022, 42 (1_SUPPL): : 242 - 243
  • [24] Noninvasive 4D Flow Characterization in a Stirred Tank via Phase-Contrast Magnetic Resonance Imaging
    Janiga, Gabor
    Stucht, Daniel
    Bordas, Robert
    Temmel, Erik
    Seidel-Morgenstern, Andreas
    Thevenin, Dominique
    Speck, Oliver
    CHEMICAL ENGINEERING & TECHNOLOGY, 2017, 40 (07) : 1370 - 1377
  • [25] Estimation of Aortic Pressure Waveforms from 4D Phase-Contrast MRI
    Delles, Michael
    Rengier, Fabian
    Jeong, Yoo-Jin
    von Tengg-Kobligk, Hendrik
    Ley, Sebastian
    Kauczor, Hans-Ulrich
    Dillmann, Ruediger
    Unterhinninghofen, Roland
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 731 - 734
  • [26] Quantification of blood flow in the carotid arteries -: Comparison of Doppler ultrasound and three different phase-contrast magnetic resonance imaging sequences
    Seitz, J
    Strotzer, M
    Wild, T
    Nitz, WR
    Völk, M
    Lenhart, M
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 2001, 36 (11) : 642 - 647
  • [27] How Flow Reduction Influences the Intracranial Aneurysm Occlusion: A Prospective 4D Phase-Contrast MRI Study
    Brina, O.
    Bouillot, P.
    Reymond, P.
    Luthman, A. S.
    Santarosa, C.
    Fahrat, M.
    Lovblad, K. O.
    Machi, P.
    Delattre, B. M. A.
    Pereira, V. M.
    Vargas, M., I
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (12) : 2117 - 2123
  • [28] 3D PHASE-CONTRAST MRI OF CEREBRAL BLOOD-FLOW AND SURFACE ANATOMY
    CLINE, HE
    LORENSEN, WE
    SCHROEDER, WJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (02) : 173 - 177
  • [29] Magnetic Resonance Assessment of Pulmonary (QP) to Systemic (QS) Flows Using 4D Phase-contrast Imaging: Pilot Study Comparison with Standard Through-plane 2D Phase-contrast Imaging
    Hanneman, Kate
    Sivagnanam, Milani
    Nguyen, Elsie T.
    Wald, Rachel
    Greiser, Andreas
    Crean, Andrew M.
    Ley, Sebastian
    Wintersperger, Bernd J.
    ACADEMIC RADIOLOGY, 2014, 21 (08) : 1002 - 1008
  • [30] Comparison of Phase-Contrast MR Imaging and Endovascular Sonography for Intracranial Blood Flow Velocity Measurements
    Schneiders, J. J.
    Ferns, S. P.
    van Ooij, P.
    Siebes, M.
    Nederveen, A. J.
    van den Berg, R.
    van Lieshout, J.
    Jansen, G.
    vanBavel, E.
    Majoie, C. B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (09) : 1786 - 1790