Three-Dimensional Optoacoustic Monitoring of Lesion Formation in Real Time During Radiofrequency Catheter Ablation

被引:51
|
作者
Pang, Genny A. [1 ,2 ,3 ]
Bay, Erwin [1 ,2 ,3 ]
Dean-Ben, X. Luis [1 ]
Razansky, Daniel [1 ,2 ,3 ]
机构
[1] Helmholtz Ctr Munich, IBMI, D-85764 Neuherberg, Germany
[2] Tech Univ Munich, Fac Med, D-80290 Munich, Germany
[3] Tech Univ Munich, Fac Elect Engn & Informat Technol, D-80290 Munich, Germany
基金
欧洲研究理事会;
关键词
catheter ablation; imaging; optoacoustic; photoacoustic; real-time; tomography; ATRIAL-FIBRILLATION; OPTICAL-PROPERTIES; TOMOGRAPHY; MODEL;
D O I
10.1111/jce.12584
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Real-Time Optoacoustic Monitoring of RF Ablation IntroductionDue to lack of reliable imaging contrast from catheter radiofrequency ablation (RFA) lesions, the vast majority of current procedures rely on indirect indicators of ablation activity, resulting in a significant number of arrhythmia reoccurrences after RFA procedures and the need for repeat surgeries. The objective of this work is to develop an accurate method for on-the-fly assessment of the durability and size of lesions formed during RFA procedures. Method and ResultsRadiofrequency catheter ablation on freshly excised porcine ventricular myocardial tissue was optoacoustically monitored by means of pulsed-laser illumination in the near-infrared spectrum. Lesion formation during ablation was captured at a rate of 10 Hz with a 256-detector optoacoustic imaging probe. Postablated samples were imaged using multispectral excitation in the wavelength range 740-860 nm to determine the lesion contrast spectrum. Tomographic reconstruction was performed to generate 3-dimensional images of the lesions, which were compared to photographs depicting the final ablated tissue samples. Video-rate 3-dimensional tomographic reconstructions depict formation of the lesion with high contrast and spatial resolution. The size and geometry of the lesion was shown to be in excellent agreement with the histological examinations. The wavelength dependence of the lesion contrast shows a contrast peak near 780 nm. ConclusionDeep-tissue 3-dimensional monitoring of RFA lesion generation in real time was demonstrated for the first time in this work. The results suggest the potential of optoacoustic monitoring for providing critical feedback on lesion position and size during radiofrequency catheter ablation, improving safety and efficacy of these treatments.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 50 条
  • [1] Optoacoustic monitoring of real-time lesion formation during radiofrequency catheter ablation
    Pang, Genny A.
    Bay, Erwin
    Dean-Ben, Xose Luis
    Razansky, Daniel
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2015, 2015, 9323
  • [2] Three-dimensional catheter positioning during radiofrequency ablation in patients: First application of a real-time position management system
    De Groot, NM
    Bootsma, M
    van der Velde, ET
    Schalij, MJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (11) : 1183 - 1192
  • [3] Real-time optoacoustic monitoring and three-dimensional mapping of a human arm vasculature
    Fronheiser, Matthew P.
    Ermilov, Sergey A.
    Brecht, Hans-Peter
    Conjusteau, Andre
    Su, Richard
    Mehta, Ketan
    Oraevsky, Alexander A.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
  • [4] Real time lesion assessment using a combined radiofrequency and ultrasound ablation catheter
    Wright, M.
    Harks, E.
    Suijver, F.
    Shi, Y.
    Deladi, S.
    Barley, M.
    Sacher, F.
    Hocini, M.
    Haissaguerre, M.
    Jais, P.
    EUROPEAN HEART JOURNAL, 2009, 30 : 272 - 272
  • [5] Characteristics of Radiofrequency Catheter Ablation Lesion Formation in Real Time In Vivo Using Near Field Ultrasound Imaging
    Wright, Matthew
    Harks, Erik
    Deladi, Szabolcs
    Fokkenrood, Steven
    Brink, Rob
    Belt, Harm
    Kolen, Alexander F.
    Rankin, Darrell
    Stoffregen, William
    Cockayne, Debra A.
    Cefalu, Joseph
    Haines, David E.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (08) : 1062 - 1072
  • [6] Real-Time Visualization of Lesion Formation Using A Combined High Frequency Ultrasound And Radiofrequency Ablation Catheter
    Wright, M.
    Harks, E.
    Deladi, S.
    Van Dusschoten, A.
    Zuo, F.
    Fokkenrood, S.
    Sacher, F.
    Hocini, M.
    Haissaguerre, M.
    Jais, P.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (04) : 490 - 490
  • [7] Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time
    Dickfeld, T
    Calkins, H
    Zviman, M
    Kato, R
    Meininger, G
    Lickfett, L
    Berger, R
    Halperin, H
    Solomon, SB
    CIRCULATION, 2003, 108 (19) : 2407 - 2413
  • [8] Detection of inadvertent catheter movement into a pulmonary vein during radiofrequency catheter ablation by real-time impedance monitoring
    Cheung, P
    Hall, B
    Chugh, A
    Good, E
    Lemola, K
    Han, J
    Tamirisa, K
    Pelosi, F
    Morady, F
    Oral, H
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (06) : 674 - 678
  • [9] TEMPERATURE MONITORING DURING RADIOFREQUENCY CATHETER ABLATION
    LANGBERG, JJ
    CIRCULATION, 1993, 87 (02) : 656 - 656
  • [10] WHAT IS THE ISOTHERM AND TIME COURSE OF LESION FORMATION IN MICROWAVE VERSUS RADIOFREQUENCY CATHETER ABLATION
    WHAYNE, JG
    NATH, S
    HAINES, DE
    CIRCULATION, 1992, 86 (04) : 783 - 783