Three-Dimensional Optoacoustic Monitoring of Lesion Formation in Real Time During Radiofrequency Catheter Ablation

被引:51
|
作者
Pang, Genny A. [1 ,2 ,3 ]
Bay, Erwin [1 ,2 ,3 ]
Dean-Ben, X. Luis [1 ]
Razansky, Daniel [1 ,2 ,3 ]
机构
[1] Helmholtz Ctr Munich, IBMI, D-85764 Neuherberg, Germany
[2] Tech Univ Munich, Fac Med, D-80290 Munich, Germany
[3] Tech Univ Munich, Fac Elect Engn & Informat Technol, D-80290 Munich, Germany
基金
欧洲研究理事会;
关键词
catheter ablation; imaging; optoacoustic; photoacoustic; real-time; tomography; ATRIAL-FIBRILLATION; OPTICAL-PROPERTIES; TOMOGRAPHY; MODEL;
D O I
10.1111/jce.12584
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Real-Time Optoacoustic Monitoring of RF Ablation IntroductionDue to lack of reliable imaging contrast from catheter radiofrequency ablation (RFA) lesions, the vast majority of current procedures rely on indirect indicators of ablation activity, resulting in a significant number of arrhythmia reoccurrences after RFA procedures and the need for repeat surgeries. The objective of this work is to develop an accurate method for on-the-fly assessment of the durability and size of lesions formed during RFA procedures. Method and ResultsRadiofrequency catheter ablation on freshly excised porcine ventricular myocardial tissue was optoacoustically monitored by means of pulsed-laser illumination in the near-infrared spectrum. Lesion formation during ablation was captured at a rate of 10 Hz with a 256-detector optoacoustic imaging probe. Postablated samples were imaged using multispectral excitation in the wavelength range 740-860 nm to determine the lesion contrast spectrum. Tomographic reconstruction was performed to generate 3-dimensional images of the lesions, which were compared to photographs depicting the final ablated tissue samples. Video-rate 3-dimensional tomographic reconstructions depict formation of the lesion with high contrast and spatial resolution. The size and geometry of the lesion was shown to be in excellent agreement with the histological examinations. The wavelength dependence of the lesion contrast shows a contrast peak near 780 nm. ConclusionDeep-tissue 3-dimensional monitoring of RFA lesion generation in real time was demonstrated for the first time in this work. The results suggest the potential of optoacoustic monitoring for providing critical feedback on lesion position and size during radiofrequency catheter ablation, improving safety and efficacy of these treatments.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 50 条
  • [41] Optical Tissue Interrogation Technology Incorporated in Irrigated Radiofrequency Ablation Provides Real Time Monitoring of Ablation Lesion Depth
    Alzahrani, Talal
    Aljishi, Mohammed
    Mercader, Marco
    CIRCULATION RESEARCH, 2016, 119
  • [42] Lower catheter tip temperatures are associated with inhomogeneous lesion formation during radiofrequency catheter ablation in a canine thigh muscle model
    Akca, F.
    Zima, E.
    Vegh, E.
    Szeplaki, G.
    Skopal, J.
    Hubay, M.
    Lendvai, Z.
    Merkely, B.
    Szili-Torok, T.
    EUROPEAN HEART JOURNAL, 2013, 34 : 430 - 430
  • [43] Real-Time 3-Dimensional Transesophageal Echocardiography During Left Atrial Radiofrequency Catheter Ablation for Atrial Fibrillation
    Mackensen, G. Burkhard
    Hegland, Donald
    Rivera, Danny
    Adams, David B.
    Bahnson, Tristram D.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2008, 1 (01) : 85 - 86
  • [44] Improved cardiac magnetic resonance thermometry and dosimetry for monitoring lesion formation during catheter ablation
    Ozenne, Valery
    Toupin, Solenn
    Bour, Pierre
    de Senneville, Baudouin Denis
    Lepetit-Coiffe, Matthieu
    Boissenin, Manuel
    Benois-Pineau, Jenny
    Hansen, Michael S.
    Inati, Souheil J.
    Govari, Assaf
    Jais, Pierre
    Quesson, Bruno
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 673 - 683
  • [45] Initial experience with catheter ablation of tachycardias using a three-dimensional real-time position management and mapping system
    Kirilmaz, Ata
    Kilicaslan, Fethi
    Ulusoy, Rifat Eralp
    Cebeci, Bekir Sitki
    Dincturk, Mehmet
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2007, 35 (01): : 1 - 8
  • [46] Feasibility of Near Real-Time Lesion Assessment During Radiofrequency Catheter Ablation in Humans Using Acoustic Radiation Force Impulse Imaging
    Bahnson, Tristram D.
    Eyerly, Stephanie A.
    Hollender, Peter J.
    Doherty, Joshua R.
    Kim, Young-Joong
    Trahey, Gregg E.
    Wolf, Patrick D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (12) : 1275 - 1283
  • [47] Real-time catheter localization and visualization using three-dimensional echocardiography
    Kozlowski, Pawel
    Bandaru, Raja Sekhar
    D'hooge, Jan
    Samset, Eigil
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [48] Near-Field Ultrasound Imaging During Radiofrequency Catheter Ablation Tissue Thickness and Epicardial Wall Visualization and Assessment of Radiofrequency Ablation Lesion Formation and Depth
    Haines, David E.
    Wright, Matthew
    Harks, Erik
    Deladi, Szabolcs
    Fokkenrood, Steven
    Brink, Rob
    Belt, Harm
    Kolen, Alexander F.
    Mihajlovic, Nenad
    Zuo, Fei
    Rankin, Darrell
    Stoffregen, William
    Cockayne, Debra
    Cefalu, Joseph
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2017, 10 (12):
  • [49] Real-Time Cardiac Catheter Navigation on Three-Dimensional CT Images
    Stephen B. Solomon
    Timm Dickfeld
    Hugh Calkins
    Journal of Interventional Cardiac Electrophysiology, 2003, 8 : 27 - 36
  • [50] Real-time cardiac catheter navigation on three-dimensional CT images
    Solomon, SB
    Dickfeld, T
    Calkins, H
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2003, 8 (01) : 27 - 36