Three-Dimensional Optoacoustic Monitoring of Lesion Formation in Real Time During Radiofrequency Catheter Ablation

被引:51
|
作者
Pang, Genny A. [1 ,2 ,3 ]
Bay, Erwin [1 ,2 ,3 ]
Dean-Ben, X. Luis [1 ]
Razansky, Daniel [1 ,2 ,3 ]
机构
[1] Helmholtz Ctr Munich, IBMI, D-85764 Neuherberg, Germany
[2] Tech Univ Munich, Fac Med, D-80290 Munich, Germany
[3] Tech Univ Munich, Fac Elect Engn & Informat Technol, D-80290 Munich, Germany
基金
欧洲研究理事会;
关键词
catheter ablation; imaging; optoacoustic; photoacoustic; real-time; tomography; ATRIAL-FIBRILLATION; OPTICAL-PROPERTIES; TOMOGRAPHY; MODEL;
D O I
10.1111/jce.12584
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Real-Time Optoacoustic Monitoring of RF Ablation IntroductionDue to lack of reliable imaging contrast from catheter radiofrequency ablation (RFA) lesions, the vast majority of current procedures rely on indirect indicators of ablation activity, resulting in a significant number of arrhythmia reoccurrences after RFA procedures and the need for repeat surgeries. The objective of this work is to develop an accurate method for on-the-fly assessment of the durability and size of lesions formed during RFA procedures. Method and ResultsRadiofrequency catheter ablation on freshly excised porcine ventricular myocardial tissue was optoacoustically monitored by means of pulsed-laser illumination in the near-infrared spectrum. Lesion formation during ablation was captured at a rate of 10 Hz with a 256-detector optoacoustic imaging probe. Postablated samples were imaged using multispectral excitation in the wavelength range 740-860 nm to determine the lesion contrast spectrum. Tomographic reconstruction was performed to generate 3-dimensional images of the lesions, which were compared to photographs depicting the final ablated tissue samples. Video-rate 3-dimensional tomographic reconstructions depict formation of the lesion with high contrast and spatial resolution. The size and geometry of the lesion was shown to be in excellent agreement with the histological examinations. The wavelength dependence of the lesion contrast shows a contrast peak near 780 nm. ConclusionDeep-tissue 3-dimensional monitoring of RFA lesion generation in real time was demonstrated for the first time in this work. The results suggest the potential of optoacoustic monitoring for providing critical feedback on lesion position and size during radiofrequency catheter ablation, improving safety and efficacy of these treatments.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 50 条
  • [31] Real-time three-dimensional optoacoustic imaging using an acoustic lens system
    Niederhauser, JJ
    Jaeger, M
    Frenz, M
    APPLIED PHYSICS LETTERS, 2004, 85 (05) : 846 - 848
  • [32] Towards patient-specific modelling of lesion formation during radiofrequency catheter ablation for atrial fibrillation
    Soor, Navjeevan
    Morgan, Ross
    Varela, Marta
    Aslanidi, Oleg V.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 489 - 492
  • [33] Three-dimensional echo decorrelation monitoring of radiofrequency ablation in ex vivo bovine liver
    Ghahramani, Z. E.
    Grimm, P. D.
    Eary, K. J.
    Swearengen, M. P.
    Dayavansha, E. G. Sunethra K.
    Mast, T. D.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2022, 151 (06): : 3907 - 3918
  • [34] TEMPERATURE MONITORING DURING RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY PATHWAYS
    LANGBERG, JJ
    CALKINS, H
    ELATASSI, R
    BORGANELLI, M
    LEON, A
    KALBFLEISCH, SJ
    MORADY, F
    CIRCULATION, 1992, 86 (05) : 1469 - 1474
  • [35] Ablation time is more important than contact force for lesion formation during radiofrequency catheter ablation in vitro model using force sensing technology
    Kim, Y. R.
    Jang, D. S.
    Joo, S. J.
    Nam, G. B.
    Choi, K. J.
    Kim, Y. H.
    EUROPEAN HEART JOURNAL, 2014, 35 : 184 - 184
  • [36] Successful radiofrequency catheter ablation for atrial fibrillation leads to left atrium reverse remodeling and functional improvement: real-time three-dimensional echocardiographic study
    Marsan, N. Ajmone
    Tops, L. F.
    Holman, E. R.
    Van de Veire, N. R.
    Zeppenfeld, K.
    Van der Wall, E. E.
    Schalij, M. J.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2008, 29 : 408 - 409
  • [37] Real-time, three-dimensional, nonfluoroscopic localization of the lasso catheter
    Wittkampf, F
    Loh, P
    Derksen, R
    Simmers, TA
    Eckardt, L
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (06) : 630 - 630
  • [38] Three-dimensional elastographic visualization of radiofrequency ablation lesions
    Varghese, T
    Techavipoo, U
    Zagzebski, JA
    Liu, W
    Frank, GR
    Lee, FT
    RADIOLOGY, 2002, 225 : 240 - 241
  • [39] Real-time optoacoustic monitoring during thermotherapy
    Esenaliev, R
    Larina, I
    Larin, K
    Motamedi, M
    BIOMEDICAL OPTOACOUSTICS, 2000, 3916 : 302 - 310
  • [40] Monitoring spinal muscular atrophy with three-dimensional optoacoustic imaging
    Nedoschill, Emmanuel
    Wagner, Alexandra L.
    Danko, Vera
    Buehler, Adrian
    Raming, Roman
    Juengert, Joerg
    Neurath, Markus F.
    Waldner, Maximilian J.
    Rother, Ulrich
    Woelfle, Joachim
    Trollmann, Regina
    Knieling, Ferdinand
    Regensburger, Adrian P.
    MED, 2024, 5 (05): : 469 - 478