Three-dimensional catheter positioning during radiofrequency ablation in patients: First application of a real-time position management system

被引:0
|
作者
De Groot, NM [1 ]
Bootsma, M [1 ]
van der Velde, ET [1 ]
Schalij, MJ [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
关键词
radiofrequency catheter ablation; three-dimensional mapping; position management; ventricular tachycardia; supraventricular tachycardia;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Precise localization of target sites for radiofrequency catheter ablation (RFCA) of arrhythmias is hampered by the relative inaccuracy of X-ray localization procedures. This study evaluated the efficacy of a three-dimensional (3D) real-time position management system in guiding RFCA procedures in patients. Methods and Results: Patients (n = 30, age 59 +/- 20 years) referred for ablation of either atrial flutter (n = 10), ventricular tachycardia (n = 15), or accessory pathways (n = 5) were studied. The real-time position management system uses ultrasound ranging techniques to track the position of an ablation catheter relative to two multitransducer reference catheters, positioned in the right atrium or coronary sinus and the right ventricle. Each catheter contains three or four ultrasound transducers, The distance between the transducer(s) is determined by calculating the time necessary for an ultrasound pulse to reach other transducers, assuming the speed of sound in blood is 1,550 m/sec. The proximal His bundle was marked at the beginning and the end of the procedure as an electrical landmark to verify reproducibility, After identification of target sites, the position of each lesion created with the ablation catheter was marked. Successful ablation was achieved in 94% of the patients, The distance between the location of the proximal His bundle as marked at the beginning and at the end of the procedure was 2.0 +/- 1.2 mm (range 1.5 to 3.5). Conclusion: The new 3D real-time position management system facilitated RFCA procedures as it allowed accurate and reproducible 3D tracking of the mapping and ablation catheter.
引用
收藏
页码:1183 / 1192
页数:10
相关论文
共 50 条
  • [1] Radiofrequency ablation of cardiac arrhythmias using a three-dimensional real-time position management and mapping system
    Schreieck, J
    Ndrepepa, G
    Zrenner, B
    Schneider, MAE
    Weyerbrock, S
    Dong, J
    Schmitt, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (12): : 1699 - 1707
  • [2] Initial experience with catheter ablation of tachycardias using a three-dimensional real-time position management and mapping system
    Kirilmaz, Ata
    Kilicaslan, Fethi
    Ulusoy, Rifat Eralp
    Cebeci, Bekir Sitki
    Dincturk, Mehmet
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2007, 35 (01): : 1 - 8
  • [3] Three-Dimensional Optoacoustic Monitoring of Lesion Formation in Real Time During Radiofrequency Catheter Ablation
    Pang, Genny A.
    Bay, Erwin
    Dean-Ben, X. Luis
    Razansky, Daniel
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (03) : 339 - 345
  • [4] Guidance of radiofrequency endocardial ablation with real-time three-dimensional magnetic navigation system
    Shpun, S
    Gepstein, L
    Hayam, G
    BenHaim, SA
    CIRCULATION, 1997, 96 (06) : 2016 - 2021
  • [5] Radio-frequency catheter ablation of ventricular tachycardia, using a three-dimensional endocardial mapping system based on the real-time positioning management system
    van der Burg, AEB
    De Groot, NMS
    Van Erven, L
    Bootsma, M
    Schalij, MJ
    EUROPEAN HEART JOURNAL, 2001, 22 : 699 - 699
  • [6] Use of a real-time three-dimensional magnetic navigation system for radiofrequency ablation of accessory pathways
    Worley, SJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (08): : 1636 - 1645
  • [7] CCD-based system for three-dimensional real-time positioning
    Pan, L
    Zhang, Q
    Xiao, XS
    Ding, HS
    Wang, GZ
    Zhao, P
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 2503 - 2506
  • [8] Delineation of areas with abnormal electrograms prior to ablation of ventricular tachycardia using a three-dimensional real-time position management system
    de Groot, NMS
    Bootsma, M
    Van der Velde, ET
    Van der Burg, AEB
    Van der Wall, EE
    Schalij, MJ
    EUROPEAN HEART JOURNAL, 2002, 23 : 162 - 162
  • [9] Anatomical stereotactic guidance of radiofrequency ablation on three-dimensional magnetic resonance images in real-time
    Dickfeld, T
    Zviman, M
    Kato, R
    Meininger, G
    Lickfett, L
    Berger, R
    Halperin, H
    Calkins, H
    Solomon, S
    CIRCULATION, 2002, 106 (19) : 332 - 332
  • [10] Optoacoustic monitoring of real-time lesion formation during radiofrequency catheter ablation
    Pang, Genny A.
    Bay, Erwin
    Dean-Ben, Xose Luis
    Razansky, Daniel
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2015, 2015, 9323