Three-dimensional catheter positioning during radiofrequency ablation in patients: First application of a real-time position management system

被引:0
|
作者
De Groot, NM [1 ]
Bootsma, M [1 ]
van der Velde, ET [1 ]
Schalij, MJ [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
关键词
radiofrequency catheter ablation; three-dimensional mapping; position management; ventricular tachycardia; supraventricular tachycardia;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Precise localization of target sites for radiofrequency catheter ablation (RFCA) of arrhythmias is hampered by the relative inaccuracy of X-ray localization procedures. This study evaluated the efficacy of a three-dimensional (3D) real-time position management system in guiding RFCA procedures in patients. Methods and Results: Patients (n = 30, age 59 +/- 20 years) referred for ablation of either atrial flutter (n = 10), ventricular tachycardia (n = 15), or accessory pathways (n = 5) were studied. The real-time position management system uses ultrasound ranging techniques to track the position of an ablation catheter relative to two multitransducer reference catheters, positioned in the right atrium or coronary sinus and the right ventricle. Each catheter contains three or four ultrasound transducers, The distance between the transducer(s) is determined by calculating the time necessary for an ultrasound pulse to reach other transducers, assuming the speed of sound in blood is 1,550 m/sec. The proximal His bundle was marked at the beginning and the end of the procedure as an electrical landmark to verify reproducibility, After identification of target sites, the position of each lesion created with the ablation catheter was marked. Successful ablation was achieved in 94% of the patients, The distance between the location of the proximal His bundle as marked at the beginning and at the end of the procedure was 2.0 +/- 1.2 mm (range 1.5 to 3.5). Conclusion: The new 3D real-time position management system facilitated RFCA procedures as it allowed accurate and reproducible 3D tracking of the mapping and ablation catheter.
引用
收藏
页码:1183 / 1192
页数:10
相关论文
共 50 条
  • [21] Ablation of atrial flutter guided by a new 3-dimensional real-time position management system: first clinical results
    de Groot, NMS
    Bootsma, M
    Schalij, MJ
    EUROPEAN HEART JOURNAL, 2000, 21 : 444 - 444
  • [22] Detection of inadvertent catheter movement into a pulmonary vein during radiofrequency catheter ablation by real-time impedance monitoring
    Cheung, P
    Hall, B
    Chugh, A
    Good, E
    Lemola, K
    Han, J
    Tamirisa, K
    Pelosi, F
    Morady, F
    Oral, H
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (06) : 674 - 678
  • [23] Evaluation of Cardiac Function Recovery in Patients with Paroxysmal Atrial Fibrillation after Catheter Radiofrequency Ablation Using Two-Dimensional Speckle Tracking Imaging and Real-Time Three-Dimensional Echocardiography
    Han, Rui
    Mei, Ying-Chen
    Li, Hai-Wei
    Li, Rong-Juan
    He, Yi-Hua
    Wang, Ze-Feng
    Wu, Yong-Quan
    CARDIOLOGY, 2024,
  • [24] THREE-DIMENSIONAL ULTRASONOGRAPHY IS USEFUL IN OPTIMIZING THE POSITION OF THE ELECTRODE IN RADIOFREQUENCY ABLATION
    Imamura, Jun
    Kimura, Kiminori
    Saeki, Shunichi
    Hayashi, Seishu
    HEPATOLOGY, 2010, 52 (04) : 1199A - 1199A
  • [25] Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time
    Dickfeld, T
    Calkins, H
    Zviman, M
    Kato, R
    Meininger, G
    Lickfett, L
    Berger, R
    Halperin, H
    Solomon, SB
    CIRCULATION, 2003, 108 (19) : 2407 - 2413
  • [26] Application value of real-time three-dimensional contrast-enhanced ultrasound for morphological assessing of hepatocellular carcinoma before radiofrequency ablation treatment
    汪贤臣
    ChinaMedicalAbstracts(InternalMedicine), 2018, 35 (02) : 110 - 110
  • [27] Clinical application of transesophageal real-time three-dimensional echocardiography
    Wang, H.
    Chen, O.
    Jiang, Y.
    Duan, F. J.
    Ye, Z. K.
    Wang, Z. M.
    Wang, Y.
    Cui, Q. Q.
    Lu, X. Z.
    Li, J. R.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 125 : S68 - S68
  • [28] Three-dimensional real-time MRI-guided intracardiac catheter navigation
    Gaspar, Thomas
    Piorkowski, Christopher
    Gutberlet, Matthias
    Hindricks, Gerhard
    EUROPEAN HEART JOURNAL, 2014, 35 (09) : 589
  • [29] First experience with real-time three-dimensional transoesophageal echocardiography-guided transseptal in patients undergoing atrial fibrillation ablation
    Chierchia, Gian Battista
    Capulzini, Lucio
    de Asmundis, Carlo
    Sarkozy, Andrea
    Roos, Markus
    Paparella, Gaetano
    Boussy, Tim
    Van Camp, Guy
    Kerkhove, Dirk
    Brugada, Pedro
    EUROPACE, 2008, 10 (11): : 1325 - 1328
  • [30] Laser system for real-time visualization of three-dimensional objects
    Savelyev, VV
    Tverdokhleb, PE
    Trubetskoi, AV
    Shchepetkin, YA
    OPTICAL MEMORY AND NEURAL NETWORKS, 1998, 3402 : 222 - 224