Dual-Frequency Chirp Excitation for Passive Cavitation Imaging in the Brain

被引:4
|
作者
Lin, Hsiang-Ching [1 ]
Fan, Ching-Hsiang [1 ]
Ho, Yi-Ju [1 ]
Yeh, Chih-Kuang [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 30013, Taiwan
关键词
Blood-brain barrier (BBB); dual-frequency chirp (DFC) excitation; microbubbles (MBs); passive cavitation imaging (PCI); ultrasound (US); GUIDED FOCUSED ULTRASOUND; BARRIER DISRUPTION; RESONANCE FREQUENCY; MICROBUBBLES; DEPENDENCE; PERMEABILITY; DOXORUBICIN; DELIVERY; DRUG;
D O I
10.1109/TUFFC.2020.2964786
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
One of the main challenges that impede cavitation-mediated imaging in the brain is restricted opening of the blood-brain barrier (BBB) making it difficult to locate cavitating microbubbles (MBs). Passive cavitation imaging (PCI) has received attention due to the possibility of performing real-time monitoring by listening to acoustic cavitation. However, the long excitation pulses associated with PCI degradeits axial resolution. The present study combined a coded excitation technique with a dual-frequency chirp (DFC) excitation method to prevent interference from the nonlinear components of MBs' cavitation. The use of DFC excitation generates a low-frequency (0.4, 0.5, or 0.6 MHz) chirp component as the envelope of the signal-driving MBs' cavitation with a dual-frequency pulse (omega 1 = 1.35 MHz and omega 2 = 1.65 MHz, omega 1 = 1.3 MHz and omega 2 = 1.7 MHz, and omega 1 = 1.25 MHz and omega 2 = 1.75 MHz). The cavitation of MBs was passively imaged utilizing a chirp component with pulse compression to maintain abundant insonation energy without any reduction in the axial imaging resolution. In vitro experiments showed that the DFC method improved the signal-to-noise ratio by 42.2% and the axial resolution by 4.1-fold compared with using a conventional long-pulse waveform. Furthermore, the cavitating MBs driven by different ultrasound (US) energy (0, 0.3, 0.6, and 0.9 MPa, N = 3 for each group) in the rat brain with an intact skull still could be mapped by DFC. Our successful demonstration of using the DFC method to image cavitation-induced BBB opening affords an alternative tool for assessing cavitation-dependent drug delivery to the brain, with the benefit of real-time and high convenient integration with current US imaging devices.
引用
收藏
页码:1127 / 1140
页数:14
相关论文
共 50 条
  • [21] Frequency-sum beamforming for passive cavitation imaging
    Abadi, Shima H.
    Haworth, Kevin J.
    Mercado-Shekhar, Karla P.
    Dowling, David R.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 144 (01): : 198 - 209
  • [22] A PASSIVE DUAL-FREQUENCY TRANSMIT-RECEIVE PROBE INTERFACE
    WONG, WF
    HERRICK, RC
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 104 (03) : 331 - 333
  • [23] Collisionless heating in capacitive discharges enhanced by dual-frequency excitation
    Turner, MM
    Chabert, P
    PHYSICAL REVIEW LETTERS, 2006, 96 (20)
  • [24] Diagnostic Method for Coriolis Flowmeters Based on Dual-Frequency Excitation
    Sun L.
    Zhang Y.
    Wang T.
    Lian J.
    Li C.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2020, 53 (04): : 433 - 440
  • [25] Phantom investigation of phase-inversion-based dual-frequency excitation imaging for improved contrast display
    Shen, Che-Chou
    Su, Shin-Yuan
    Cheng, Chih-Hao
    Yeh, Chih-Kuang
    ULTRASONICS, 2012, 52 (01) : 25 - 32
  • [26] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, ME
    Goertz, DE
    Vos, HJ
    Droog, E
    Blacquière, G
    Gisolf, A
    van der Steen, AFW
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 241 - 244
  • [27] Dual-Frequency Transducer for Nonlinear Contrast Agent Imaging
    Guiroy, Axel
    Novell, Anthony
    Ringgaard, Erling
    Lou-Moeller, Rasmus
    Gregoire, Jean-Marc
    Abellard, Andre-Pierre
    Zawada, Tomasz
    Bouakaz, Ayache
    Levassort, Franck
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (12) : 2634 - 2644
  • [28] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, Martijn E.
    Goertz, David E.
    Vos, Hendrik J.
    Tesselaar, Erik
    Blacquiere, Gerrit
    Gisolf, Andries
    Krams, Rob
    van der Steen, Antonius F. W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (11): : 1649 - 1654
  • [29] Dual-frequency transducer for nonlinear contrast agent imaging
    Guiroy, A.
    Abellard, A.
    Levassort, F.
    Ringgaard, E.
    Lou-Moeller, R.
    Zawada, T.
    Novell, A.
    Gregoire, J. M.
    Bouakaz, A.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
  • [30] Transparent Dual-Frequency CMUT Arrays for Photoacoustic Imaging
    Ghavami, Mahyar
    Sobhani, Mohammad Rahim
    Zemp, Roger
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (12) : 1621 - 1630