Dual-Frequency Chirp Excitation for Passive Cavitation Imaging in the Brain

被引:4
|
作者
Lin, Hsiang-Ching [1 ]
Fan, Ching-Hsiang [1 ]
Ho, Yi-Ju [1 ]
Yeh, Chih-Kuang [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 30013, Taiwan
关键词
Blood-brain barrier (BBB); dual-frequency chirp (DFC) excitation; microbubbles (MBs); passive cavitation imaging (PCI); ultrasound (US); GUIDED FOCUSED ULTRASOUND; BARRIER DISRUPTION; RESONANCE FREQUENCY; MICROBUBBLES; DEPENDENCE; PERMEABILITY; DOXORUBICIN; DELIVERY; DRUG;
D O I
10.1109/TUFFC.2020.2964786
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
One of the main challenges that impede cavitation-mediated imaging in the brain is restricted opening of the blood-brain barrier (BBB) making it difficult to locate cavitating microbubbles (MBs). Passive cavitation imaging (PCI) has received attention due to the possibility of performing real-time monitoring by listening to acoustic cavitation. However, the long excitation pulses associated with PCI degradeits axial resolution. The present study combined a coded excitation technique with a dual-frequency chirp (DFC) excitation method to prevent interference from the nonlinear components of MBs' cavitation. The use of DFC excitation generates a low-frequency (0.4, 0.5, or 0.6 MHz) chirp component as the envelope of the signal-driving MBs' cavitation with a dual-frequency pulse (omega 1 = 1.35 MHz and omega 2 = 1.65 MHz, omega 1 = 1.3 MHz and omega 2 = 1.7 MHz, and omega 1 = 1.25 MHz and omega 2 = 1.75 MHz). The cavitation of MBs was passively imaged utilizing a chirp component with pulse compression to maintain abundant insonation energy without any reduction in the axial imaging resolution. In vitro experiments showed that the DFC method improved the signal-to-noise ratio by 42.2% and the axial resolution by 4.1-fold compared with using a conventional long-pulse waveform. Furthermore, the cavitating MBs driven by different ultrasound (US) energy (0, 0.3, 0.6, and 0.9 MPa, N = 3 for each group) in the rat brain with an intact skull still could be mapped by DFC. Our successful demonstration of using the DFC method to image cavitation-induced BBB opening affords an alternative tool for assessing cavitation-dependent drug delivery to the brain, with the benefit of real-time and high convenient integration with current US imaging devices.
引用
收藏
页码:1127 / 1140
页数:14
相关论文
共 50 条
  • [31] Effect of different waveforms and harmonic frequency orders on bubble cavitation in dual-frequency ultrasonic intensification
    Seithtanabutara, Varinrumpai
    Jookjantra, Kittichai
    Wongwuttanasatian, Tanakorn
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 157
  • [32] INVESTIGATION OF DUAL-FREQUENCY EXCITATION AND THE INFLUENCE OF EXCITATION PHASE ON A CONSTRAINED CANTILEVERED BEAM SYSTEM
    Huang, Wei
    Atzil, Aaron M.
    Dick, Andrew J.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2014, VOL 4, 2014,
  • [33] Characterization of Stable and Transient Cavitation in a Dual-Frequency Acoustic Field Using a Hydrophone
    Mingrui Zhao
    Anfal Alobeidli
    Xi Chen
    Petrie Yam
    Claudio Zanelli
    Manish Keswani
    MRS Advances, 2016, 1 (31) : 2247 - 2253
  • [34] Characterization of Stable and Transient Cavitation in a Dual-Frequency Acoustic Field Using a Hydrophone
    Zhao, Mingrui
    Alobeidli, Anfal
    Chen, Xi
    Yam, Petrie
    Zanelli, Claudio
    Keswani, Manish
    MRS ADVANCES, 2016, 1 (31): : 2247 - 2253
  • [35] Single-transducer dual-frequency ultrasound generation to enhance acoustic cavitation
    Liu, Hao-Li
    Hsieh, Chao-Ming
    ULTRASONICS SONOCHEMISTRY, 2009, 16 (03) : 431 - 438
  • [36] Difference-frequency ultrasound generation from microbubbles under dual-frequency excitation
    马青玉
    邱媛媛
    黄蓓
    章东
    龚秀芬
    Chinese Physics B, 2010, 19 (09) : 441 - 446
  • [37] Difference-frequency ultrasound generation from microbubbles under dual-frequency excitation
    Ma Qing-Yu
    Qiu Yuan-Yuan
    Huang Bei
    Zhang Dong
    Gong Xiu-Fen
    CHINESE PHYSICS B, 2010, 19 (09)
  • [38] High-Intensity Focused Ultrasound Ablation by the Dual-Frequency Excitation
    Law, Siu Kwun Berlinda
    Zhou, Yufeng
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (01) : 18 - 25
  • [39] An optimized approach to membrane capacitance estimation using dual-frequency excitation
    Barnett, DW
    Misler, S
    BIOPHYSICAL JOURNAL, 1997, 72 (04) : 1641 - 1658
  • [40] Chaotic oscillations of gas bubbles under dual-frequency acoustic excitation
    Zhang, Yuning
    Zhang, Yuning
    ULTRASONICS SONOCHEMISTRY, 2018, 40 : 151 - 157