Dual-Frequency Transducer for Nonlinear Contrast Agent Imaging

被引:24
|
作者
Guiroy, Axel [1 ]
Novell, Anthony [2 ]
Ringgaard, Erling [3 ]
Lou-Moeller, Rasmus [3 ]
Gregoire, Jean-Marc [2 ]
Abellard, Andre-Pierre [1 ]
Zawada, Tomasz [3 ]
Bouakaz, Ayache [2 ]
Levassort, Franck [1 ]
机构
[1] Univ Tours, CNRS, GREMAN UMR7347, Tours, France
[2] Val de Loire Univ, Univ Tours, PRES Ctr, Inserm,UMR U930, Tours, France
[3] MEGGITT AS, Kvistgaard, Denmark
关键词
PIEZOELECTRIC THICK-FILMS; ULTRASONIC TRANSDUCERS; PSEUDOSPECTRAL METHOD; IN-VIVO; ATTENUATION; TISSUE;
D O I
10.1109/TUFFC.2013.2862
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Detection of high-order nonlinear components issued from microbubbles has emerged as a sensitive method for contrast agent imaging. Nevertheless, the detection of these high-frequency components, including the third, fourth, and fifth harmonics, remains challenging because of the lack of transducer sensitivity and bandwidth. In this context, we propose a new design of imaging transducer based on a simple fabrication process for high-frequency nonlinear imaging. The transducer is composed of two elements: the outer low-frequency (LF) element was centered at 4 MHz and used in transmit mode, whereas the inner high-frequency (HF) element centered at 14 MHz was used in receive mode. The center element was pad-printed using a lead zirconate titanate (PZT) paste. The outer element was molded using a commercial PZT, and curved porous unpoled PZT was used as backing. Each piezoelectric element was characterized to determine the electromechanical performance with thickness coupling factor around 45%. After the assembly of the two transducer elements, hydrophone measurements (electroacoustic responses and radiation patterns) were carried out and demonstrated a large bandwidth (70% at -3 dB) of the HF transducer. Finally, the transducer was evaluated for contrast agent imaging using contrast agent microbubbles. The results showed that harmonic components (up to the sixth harmonic) of the microbubbles were successfully detected. Moreover, images from a flow phantom were acquired and demonstrated the potential of the transducer for high-frequency nonlinear contrast imaging.
引用
收藏
页码:2634 / 2644
页数:11
相关论文
共 50 条
  • [1] Dual-frequency transducer for nonlinear contrast agent imaging
    Guiroy, A.
    Abellard, A.
    Levassort, F.
    Ringgaard, E.
    Lou-Moeller, R.
    Zawada, T.
    Novell, A.
    Gregoire, J. M.
    Bouakaz, A.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
  • [2] Characterization of an Array-Based Dual-Frequency Transducer for Superharmonic Contrast Imaging
    Yang, Jing
    Cherin, Emmanuel
    Yin, Jianhua
    Newsome, Isabel G.
    Kierski, Thomas M.
    Pang, Guofeng
    Carnevale, Claudia A.
    Dayton, Paul A.
    Foster, F. Stuart
    Demore, Christine E. M.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (07) : 2419 - 2431
  • [3] Dual-frequency chirp imaging for contrast detection
    Cheng, Chih-Hao
    Shen, Che-Chou
    Yeh, Chih-Kuang
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09): : 2767 - 2778
  • [4] Dual-Frequency Transducer with a Wideband PVDF Receiver for Contrast-Enhanced, Adjustable Harmonic Imaging
    Kim, Jinwook
    Lindsey, Brooks D.
    Li, Sibo
    Dayton, Paul A.
    Jiang, Xiaoning
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2017, 2017, 10170
  • [5] A Dual-Frequency Coupled Resonator Transducer
    Andersen, Kenneth Kirkeng
    Frijlink, Martijn E.
    Johansen, Tonni Franke
    Hoff, Lars
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (10) : 2119 - 2129
  • [6] A Dual-Frequency Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer
    Lindsey, Brooks D.
    Dayton, Paul A.
    Kim, Jinwook
    Jiang, Xiaoning
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [7] Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging
    Martin, K. Heath
    Lindsey, Brooks D.
    Ma, Jianguo
    Lee, Mike
    Li, Sibo
    Foster, F. Stuart
    Jiang, Xiaoning
    Dayton, Paul A.
    SENSORS, 2014, 14 (11) : 20825 - 20842
  • [8] Dual-frequency IVUS transducer for acoustic radiation force impulse (ARFI) imaging
    Wang, Zhuochen
    Jiang, Xiaoning
    Czernuszewicz, Tomasz J.
    Gallippi, Caterina M.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [9] Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer
    Lindsey, Brooks D.
    Kim, Jinwook
    Dayton, Paul A.
    Jiang, Xiaoning
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (07) : 1078 - 1086
  • [10] IN VITRO SUPERHARMONIC CONTRAST IMAGING USING A HYBRID DUAL-FREQUENCY PROBE
    Cherin, Emmanuel
    Yin, Jianhua
    Forbrich, Alex
    White, Christopher
    Dayton, Paul A.
    Foster, F. Stuart
    Demore, Christine E. M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (09): : 2525 - 2539