Substrate diffusion from an array of capillaries with co-current and counter-current flow

被引:0
|
作者
Teboh-Ewungkem, MI [1 ]
Salathe, EP [1 ]
机构
[1] Lehigh Univ, Inst Biomed Engn & Math Biol, Dept Math, Bethlehem, PA 18015 USA
关键词
microcirculation; transport; mathematical model; multicapillary; counter-current flow;
D O I
10.1016/j.mcm.2005.05.012
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A method is presented for analyzing the exchange of substrates from a two-dimensional array of parallel capillaries arranged in a manner characteristic of skeletal muscle. In general, the tissue is nonuniformly perfused by these capillaries, and large scale diffusion occurs from the regions that are richly perfused to the regions that are poorly perfused. The method developed leads to a coupled system of nonlinear ordinary differential equations for the substrate concentration within the capillaries, and is easy to apply even for vascular beds containing a large number of capillaries. Interaction among the capillaries is examined for the case when the flow in all the capillaries is in the same direction, co-current flow, and when some of the capillaries are flowing in the opposite direction, counter-current flow. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:17 / 30
页数:14
相关论文
共 50 条
  • [11] Co-current and counter-current spraying of odour-neutralizing products
    Bouzin-Turpin, Aurelie
    Couvert, Annabelle
    Laplanche, Alain
    Paillier, Anne
    [J]. ENVIRONMENTAL TECHNOLOGY, 2009, 30 (14) : 1511 - 1517
  • [12] Co-current and counter-current fixed bed combustion of biofuel - a comparison
    Thunman, H
    Leckner, B
    [J]. FUEL, 2003, 82 (03) : 275 - 283
  • [13] EFFECT OF CO-CURRENT AND COUNTER-CURRENT AIR FLOW IN WAVE PROPERTIES OF FALLING LIQUID FILMS
    STAINTHORPE, FP
    BATT, RSW
    [J]. TRANSACTIONS OF THE INSTITUTION OF CHEMICAL ENGINEERS AND THE CHEMICAL ENGINEER, 1967, 45 (09): : T372 - +
  • [14] On the conditional superiority of counter-current over co-current extraction in microchannels
    Picardo, J. R.
    Pushpavanam, S.
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2013, 15 (05) : 701 - 713
  • [15] Co-current and counter-current modes for water gas shift membrane reactor
    Basile, A
    Paturzo, L
    Gallucci, F
    [J]. CATALYSIS TODAY, 2003, 82 (1-4) : 275 - 281
  • [16] Performance evaluation of a rotary dryer in both co-current and counter-current configurations
    Echeeri, Asmae
    Maalmi, Mostafa
    [J]. JOURNAL OF THERMAL ENGINEERING, 2021, 7 (08): : 1945 - 1957
  • [17] Co-current and counter-current modes for methanol steam reforming membrane reactor
    Gallucci, Fausto
    Basile, Angelo
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2006, 31 (15) : 2243 - 2249
  • [18] Modeling of co-current and counter-current bubble columns with an extended EMMS approach
    Guan, Xiaoping
    Yang, Ning
    [J]. PARTICUOLOGY, 2019, 44 : 126 - 135
  • [19] A Comparison of Co-current and Counter-current Modes of Operation in Urea Prilling Tower
    Rahamnian, Nejat
    Homayoonfard, Marjan
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON PROCESS ENGINEERING AND ADVANCED MATERIALS 2012-ICPEAM 2012, 2014, 917 : 199 - 208
  • [20] Performance of co-current and counter-current parallel flow three-fluid heat exchanger due to perturbations in flow
    Singh, Sanjay Kumar
    Mishra, Manish
    Jha, P. K.
    [J]. INTERNATIONAL JOURNAL OF GLOBAL ENERGY ISSUES, 2016, 39 (3-4) : 144 - 156