Co-current and counter-current spraying of odour-neutralizing products

被引:1
|
作者
Bouzin-Turpin, Aurelie [1 ,2 ]
Couvert, Annabelle [1 ,2 ]
Laplanche, Alain [1 ,2 ]
Paillier, Anne [3 ]
机构
[1] Ecole Natl Super Chim Rennes, CNRS, UMR 6226, CS 50837, F-35708 Rennes 7, France
[2] Univ Europeenne Bretagne, Rennes, France
[3] ADEME, F-49000 Angers, France
关键词
diffuse odour emissions; reactive absorption; neutralizing products; physico-chemical efficiency; olfactometry; MASS-TRANSFER; SURFACTANTS; ABSORPTION; COLUMNS;
D O I
10.1080/09593330903241946
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A lab-scale pilot plant was developed in order to measure the efficiency of some odour-neutralizing products for the removal of odorous compounds. Experiments were carried out on gas and liquid flows in two configurations: co-current and counter-current, which differ in the values of the drop diameter and the contact time, leading to different behaviours between highly water-soluble compounds like ammonia and other compounds like sulphurous compounds. Mass transfer was shown to be modified by the presence of neutralizing products as a result of their pH and surface tension. Few chemical reactions, except for acidic or basic ones, could be highlighted. Olfactometric analyses were carried out and showed that, because of possible confusion between odours caused by the neutralizing product and odours caused by the by-products, it was difficult to conclude that an obvious relation existed between physico-chemical and olfactometric efficiencies.
引用
收藏
页码:1511 / 1517
页数:7
相关论文
共 50 条
  • [1] HEATING OF POWDERS IN COUNTER-CURRENT AND CO-CURRENT INDUCTION PLASMAS
    WALDIE, B
    [J]. TRANSACTIONS OF THE INSTITUTION OF CHEMICAL ENGINEERS AND THE CHEMICAL ENGINEER, 1971, 49 (02): : 114 - &
  • [2] Co-current drying plus counter-current cooling in a rotary drum
    Trojosky, M.
    Stölzner, G.
    Fill, C.
    [J]. Cement International, 2019, 17 (04): : 54 - 61
  • [3] On the conditional superiority of counter-current over co-current extraction in microchannels
    J. R. Picardo
    S. Pushpavanam
    [J]. Microfluidics and Nanofluidics, 2013, 15 : 701 - 713
  • [4] Semiglobal Exponential Stability of a Counter-Current and Co-Current Guidance Scheme
    Caharija, Walter
    Grotli, Esten I.
    Pettersen, Kristin Y.
    [J]. IFAC PAPERSONLINE, 2018, 51 (29): : 274 - 280
  • [5] Co-current and counter-current fixed bed combustion of biofuel - a comparison
    Thunman, H
    Leckner, B
    [J]. FUEL, 2003, 82 (03) : 275 - 283
  • [6] Multiphase Flow in Fractures: Co-Current and Counter-Current Flow in a Fracture
    Shad, S.
    Gates, I. D.
    [J]. JOURNAL OF CANADIAN PETROLEUM TECHNOLOGY, 2010, 49 (02): : 48 - 55
  • [7] On the conditional superiority of counter-current over co-current extraction in microchannels
    Picardo, J. R.
    Pushpavanam, S.
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2013, 15 (05) : 701 - 713
  • [8] Co-current and counter-current modes for water gas shift membrane reactor
    Basile, A
    Paturzo, L
    Gallucci, F
    [J]. CATALYSIS TODAY, 2003, 82 (1-4) : 275 - 281
  • [9] Substrate diffusion from an array of capillaries with co-current and counter-current flow
    Teboh-Ewungkem, MI
    Salathe, EP
    [J]. MATHEMATICAL AND COMPUTER MODELLING, 2005, 42 (1-2) : 17 - 30
  • [10] Co-current and counter-current modes for methanol steam reforming membrane reactor
    Gallucci, Fausto
    Basile, Angelo
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2006, 31 (15) : 2243 - 2249