Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures

被引:31
|
作者
Lever, James P. [2 ]
Aksenov, Sergei A. [2 ]
Zdero, Rad [1 ]
Ahn, Henry [2 ]
Mckee, Michael D. [2 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Univ Toronto, Dept Surg, Toronto, ON, Canada
关键词
biomechanics; proximal humerus; fracture; plate fixation;
D O I
10.1097/BOT.0b013e31815c89ce
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To biomechanically assess five proximal, humeral, fracture-plate-fixation systems. Methods: Surgical neck fractures, with and without cortical contact, were created in 25 fresh-frozen cadaveric humeri. Five methods of plate fixation were used for repair: construct A [an eight-hole, low contact dynamic compression (LCDC) plate contoured into a blade shape, supported by one, 70-mm-long, 4.5-mm-diameter cortical screw acting as a truss], construct B (a 10-hole LCDC plate arrangement identical to construct A, but using one, 70-mm-long, 3.5-mm-diameter cortical screw as a truss), construct C [a five-hole dynamic compression (DC) blade plate with one, 6.5-mm-diameter cancellous screw], construct D (a five-hole T-plate supported by three, 6.5-mm-diameter cancellous screws), and construct E (a five-hole cloverleaf plate supported by five, 4-mm-diameter cancellous screws). Plates were posterior to the bicipital groove, 10 mm distal to the greater tuberosity tip, on the lateral aspect of the humeral shaft. Screw fixation was done using standard AO compression plating techniques. Stiffness of constructs was measured in bending and axial compression. Locked plates were not assessed. Results: For cortical contact [abduction of 20 degrees (P = 0.02), flexion of 20 degrees (P = 0.02), flexion of 90 degrees (P = 0.005)] and no cortical contact [flexion of 90 degrees (P = 0.0001)], construct A was significantly stiffer than other constructs. For no cortical contact in abduction of 90 degrees (P = 0.05), construct A was significantly stiffer than other constructs. Conclusions: Construct A was significantly stiffer than other constructs.
引用
收藏
页码:23 / 29
页数:7
相关论文
共 50 条
  • [1] Locking plate osteosynthesis for fractures of the proximal humerus
    Lungershausen, W
    Bach, O
    Lorenz, CO
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (01): : 28 - 33
  • [2] Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review
    Jabran, Ali
    Peach, Chris
    Ren, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [3] Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review
    Ali Jabran
    Chris Peach
    Lei Ren
    BioMedical Engineering OnLine, 17
  • [4] Plate Osteosynthesis of Proximal Ulna Fractures-A Biomechanical Micromotion Analysis
    Hackl, Michael
    Mayer, Katharina
    Weber, Mareike
    Staat, Manfred
    van Riet, Roger
    Burkhart, Klaus Josef
    Mueller, Lars Peter
    Wegmann, Kilian
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (10): : 834.e1 - 834.e7
  • [5] Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study
    Hessmann, Martin H.
    Korner, Jan
    Hofmann, Alexander
    Sternstein, Werner
    Rommens, Pol M.
    BIOMEDIZINISCHE TECHNIK, 2008, 53 (03): : 130 - 137
  • [6] Minimally invasive plate osteosynthesis with PHILOS plate for proximal humerus fractures
    Gonc, Ugur
    Atabek, Mesut
    Teker, Kursat
    Tanriover, Altug
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (01) : 17 - 22
  • [7] Minimal invasive PHILOS®-plate osteosynthesis of proximal humerus fractures
    Acklin, Y. P.
    Jenni, R.
    Walliser, M.
    Sommer, C.
    BRITISH JOURNAL OF SURGERY, 2007, 94 (06) : 769 - 769
  • [8] Minimally invasive plate osteosynthesis (MIPO) in diaphyseal humerus and proximal humerus fractures
    Aksu, Neslihan
    Karaca, Sinan
    Kara, Ayhan Nedim
    Isiklar, Zekeriya Ugur
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (03) : 154 - 160
  • [9] Biomechanical investigation of fixed-angle plate osteosynthesis of the proximal humerus
    Roederer, G.
    AbouElsoud, M.
    Gebhard, F.
    Claes, L.
    Aschoff, A. J.
    Kinzl, L.
    UNFALLCHIRURG, 2010, 113 (02): : 133 - 138
  • [10] Is Medial Calcar Continuity Necessary in Plate Osteosynthesis for Proximal Humerus Fractures?
    Esenyel, C. Z.
    Kalkar, I.
    Adas, M.
    Dedeoglu, S. S.
    Buyukkurt, C. D.
    Cabuk, H.
    Esenyel, A. E.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (03) : 362 - 366