Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures

被引:31
|
作者
Lever, James P. [2 ]
Aksenov, Sergei A. [2 ]
Zdero, Rad [1 ]
Ahn, Henry [2 ]
Mckee, Michael D. [2 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Univ Toronto, Dept Surg, Toronto, ON, Canada
关键词
biomechanics; proximal humerus; fracture; plate fixation;
D O I
10.1097/BOT.0b013e31815c89ce
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To biomechanically assess five proximal, humeral, fracture-plate-fixation systems. Methods: Surgical neck fractures, with and without cortical contact, were created in 25 fresh-frozen cadaveric humeri. Five methods of plate fixation were used for repair: construct A [an eight-hole, low contact dynamic compression (LCDC) plate contoured into a blade shape, supported by one, 70-mm-long, 4.5-mm-diameter cortical screw acting as a truss], construct B (a 10-hole LCDC plate arrangement identical to construct A, but using one, 70-mm-long, 3.5-mm-diameter cortical screw as a truss), construct C [a five-hole dynamic compression (DC) blade plate with one, 6.5-mm-diameter cancellous screw], construct D (a five-hole T-plate supported by three, 6.5-mm-diameter cancellous screws), and construct E (a five-hole cloverleaf plate supported by five, 4-mm-diameter cancellous screws). Plates were posterior to the bicipital groove, 10 mm distal to the greater tuberosity tip, on the lateral aspect of the humeral shaft. Screw fixation was done using standard AO compression plating techniques. Stiffness of constructs was measured in bending and axial compression. Locked plates were not assessed. Results: For cortical contact [abduction of 20 degrees (P = 0.02), flexion of 20 degrees (P = 0.02), flexion of 90 degrees (P = 0.005)] and no cortical contact [flexion of 90 degrees (P = 0.0001)], construct A was significantly stiffer than other constructs. For no cortical contact in abduction of 90 degrees (P = 0.05), construct A was significantly stiffer than other constructs. Conclusions: Construct A was significantly stiffer than other constructs.
引用
收藏
页码:23 / 29
页数:7
相关论文
共 50 条
  • [21] Clinical outcome after minimal invasive plate osteosynthesis for proximal humerus fractures
    Acklin, Y.
    Stoffel, K.
    Sommer, C.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 11 - 12
  • [22] Minimal invasive long PHILOS®-plate osteosynthesis in metadiaphyseal fractures of the proximal humerus
    Rancan, Mario
    Dietrich, Michael
    Lamdark, Tenzin
    Can, Uenal
    Platz, Andreas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (12): : 1277 - 1283
  • [23] Biology and Biomechanics in Osteosynthesis of Proximal Humerus Fractures
    Pierre Hepp
    Christoph Josten
    European Journal of Trauma and Emergency Surgery, 2007, 33 : 337 - 344
  • [24] Biology and biomechanics in osteosynthesis of proximal humerus fractures
    Hepp, Pierre
    Josten, Christoph
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2007, 33 (04) : 337 - 344
  • [25] Minimally Invasive Plate Osteosynthesis Using a Helical Plate for Metadiaphyseal Complex Fractures of the Proximal Humerus
    Moon, Jun-Gyu
    Kwon, Hyuk-Nam
    Biraris, Sandeep
    Shon, Won-Yong
    ORTHOPEDICS, 2014, 37 (03) : E237 - E243
  • [26] OSTEOSYNTHESIS OF FRACTURES OF PROXIMAL END OF HUMERUS AND RESULTS
    MULLER, HA
    KOUDSI, F
    AKTUELLE TRAUMATOLOGIE, 1978, 8 (02): : 143 - 148
  • [27] Minimally invasive plate osteosynthesis of the proximal humerus
    Acklin, Y. P.
    Sommer, C.
    TRAUMA UND BERUFSKRANKHEIT, 2011, 13 (04) : 234 - 238
  • [28] Parallel versus orthogonal plate osteosynthesis of adult distal humerus fractures: a meta-analysis of biomechanical studies
    Chien-An Shih
    Wei-Ren Su
    Wei-Chin Lin
    Tai-Wei Tai
    International Orthopaedics, 2019, 43 : 449 - 460
  • [29] Minimally invasive percutaneous plate osteosynthesis for the treatment of proximal humerus fractures in osteoporotic patients with Philos plate
    Sahu, R. J. L.
    BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2013, 12 (02): : 140 - 145
  • [30] Medial support for treatment of fractures of the proximal humerus by retrograde nail osteosynthesis: biomechanical and clinical aspects
    Dietz, Sven Oliver
    Sohlbach, D.
    Kuechle, R.
    Enders, A.
    Hartmann, F.
    Nowak, T. E.
    Hofmann, A.
    Isemer, F. E.
    Rommens, P. M.