Intelligent Health Monitoring System for a Railway Cable-Stayed Bridge

被引:0
|
作者
Shan, Deshan [1 ]
Yan, Peng [1 ]
Wang, Zhenhua [1 ]
机构
[1] SW Jiaotong Univ, Bridge Engn Dept, Chengdu, Sichuan Prov, Peoples R China
来源
关键词
structural health monitoring system; measurement system; railway; cable-stayed bridge; instrumentation;
D O I
10.4028/www.scientific.net/AMR.148-149.1390
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Intelligent health monitoring system of the long-span railway cable-stayed bridge requires the comprehensive knowledge of instrumentation, analytical and information processing technologies with the knowledge and experiences in design, construction, operation and maintenance of railway cable-stayed bridge for long-term monitoring the performance throughout its lifecycle. It is necessary to perform sensor-based structural monitoring for identifying the bridge conditions in order to assure the structural safety and to evaluate the operational performance. The considerations for deploying a proper monitoring system are appropriate sensor instrumentation, robust signal acquisition, reliable signal processing, and intelligent signal and information processing. The experience on developing an autonomous monitoring system in the one certain railway cable-stayed bridge newly constructed is introduced in this paper. Sensor and hardware instrumentation, signal transmission, signal acquisition and analysis are schematically described mainly. Experience through this work will be worthwhile lessons for other similar efforts.
引用
收藏
页码:1390 / 1393
页数:4
相关论文
共 50 条
  • [41] The Millau cable-stayed bridge
    Virlogeux, M
    RECENT DEVELOPMENTS IN BRIDGE ENGINEERING, 2003, : 3 - 18
  • [42] Innovative cable-stayed bridge
    Christoffersen, Jens
    Jensen, Henrik Elgaard
    Hauge, Lars
    Bjerrum, John
    Concrete (London), 1998, 32 (07): : 32 - 34
  • [43] The colletta cable-stayed bridge
    Petrangeli, Mario Paolo
    Industria Italiana del Cemento, 2006, 76 (823): : 728 - 743
  • [44] Cable-stayed pedestrian bridge
    Fernandez, P
    PCI JOURNAL, 2000, 45 (04): : 119 - 119
  • [45] Vision-based monitoring system for estimating cable tensile forces of cable-stayed bridge
    Kim, S. W.
    Kim, N. S.
    Jeon, B. G.
    Park, J. C.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 970 - 977
  • [46] Vision-based monitoring system for evaluating cable tensile forces on a cable-stayed bridge
    Kim, Sung-Wan
    Jeon, Bub-Gyu
    Kim, Nam-Sik
    Park, Jong-Chil
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2013, 12 (5-6): : 440 - 456
  • [47] Design Innovation and Practice of Railway Hybrid Girder Cable-stayed Bridge
    Liu, Zhenbiao
    Wen, Wangqing
    Chen, Liangjiang
    Journal of Railway Engineering Society, 2019, 36 (05): : 30 - 36
  • [48] Cable-beam related vibration of a long span railway cable-stayed bridge
    Wang T.
    Liu D.
    Huang H.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (17): : 103 - 114
  • [49] CABLE-STAYED BRIDGE LOADS CAUSED BY TRAFFIC CONGESTION ON THE DECK MEASURED WITH BRIDGE MONITORING SYSTEM
    Machelski, Czeslaw
    Hildebrand, Maciej
    BALTIC JOURNAL OF ROAD AND BRIDGE ENGINEERING, 2021, 16 (02): : 66 - 89
  • [50] DEVELOPMENT AND APPLICATION OF A BWIM SYSTEM IN A CABLE-STAYED BRIDGE
    Park, Minsuck
    Lee, Jungwhee
    Kim, Sungkon
    Jo, Byungwan
    Jang, Jeonghwan
    Park, Youngha
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON STRUCTURE HEALTH MONITORING & INTELLIGENT INFRASTRUCTURE: STRUCTURAL HEALTH MONITORING & INTELLIGENT INFRASTRUCTURE, 2007,