Intelligent Health Monitoring System for a Railway Cable-Stayed Bridge

被引:0
|
作者
Shan, Deshan [1 ]
Yan, Peng [1 ]
Wang, Zhenhua [1 ]
机构
[1] SW Jiaotong Univ, Bridge Engn Dept, Chengdu, Sichuan Prov, Peoples R China
来源
关键词
structural health monitoring system; measurement system; railway; cable-stayed bridge; instrumentation;
D O I
10.4028/www.scientific.net/AMR.148-149.1390
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Intelligent health monitoring system of the long-span railway cable-stayed bridge requires the comprehensive knowledge of instrumentation, analytical and information processing technologies with the knowledge and experiences in design, construction, operation and maintenance of railway cable-stayed bridge for long-term monitoring the performance throughout its lifecycle. It is necessary to perform sensor-based structural monitoring for identifying the bridge conditions in order to assure the structural safety and to evaluate the operational performance. The considerations for deploying a proper monitoring system are appropriate sensor instrumentation, robust signal acquisition, reliable signal processing, and intelligent signal and information processing. The experience on developing an autonomous monitoring system in the one certain railway cable-stayed bridge newly constructed is introduced in this paper. Sensor and hardware instrumentation, signal transmission, signal acquisition and analysis are schematically described mainly. Experience through this work will be worthwhile lessons for other similar efforts.
引用
收藏
页码:1390 / 1393
页数:4
相关论文
共 50 条
  • [21] Bridge management system development for a cable-stayed bridge
    Sungkon Kim
    KSCE Journal of Civil Engineering, 2001, 5 (1) : 43 - 49
  • [22] Application of Wireless Monitoring System to Structural Health Monitoring of Long-Spanned Cable-Stayed Bridge
    孟庆成
    齐欣
    李乔
    Journal of Southwest Jiaotong University(English Edition), 2007, (02) : 117 - 121
  • [23] On-line deflection monitoring system for DAFOSI cable-stayed bridge
    Zhu, Y
    Fu, YM
    Chen, WM
    Huang, SL
    SMART MATERIALS FOR ENGINEERING AND BIOMEDICAL APPLICATIONS, PROCEEDINGS, 2004, : 125 - 132
  • [24] Modal characteristics of a large span railway cable-stayed bridge
    Chen, Rui-Lin
    Zeng, Qin-Yuan
    Huang, Yun-Qing
    Xiang, Jun
    Wen, Ying
    Xiao, Ying-Xiong
    Guo, Xiao-Gang
    Zhang, Jun-Yan
    Zhendong yu Chongji/Journal of Vibration and Shock, 2010, 29 (02): : 7 - 10
  • [25] HEALTH MONITORING AND EVALUATION SYSTEM FOR CABLE-STAYED BRIDGE USING COMPUTATIONAL SIMULATION AND SENSOR DATA
    Xie, Haibo
    Tian, Zhongchu
    Zheng, Wanggang
    Zhou, Yuxiang
    INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE PERFORMANCE OF BRIDGES AND STRUCTURES, 2010, : 185 - 188
  • [26] Hybrid networking sensing system for structural health monitoring of a concrete cable-stayed bridge.
    Torbol, Marco
    Kim, Sehwan
    Chien, Ting-Chou
    Shinozuka, Masanobu
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2013, 2013, 8692
  • [27] Overview of integrated health monitoring system installed on cable-stayed bridge and preliminary analysis of results
    Wang, Chao
    GRADEVINAR, 2021, 73 (06): : 591 - 604
  • [28] Long-time Health Monitoring System of an In-service Concrete Cable-stayed Bridge
    Zeng, Y.
    Tan, H.
    Zhang, X.
    Jiang, X.
    Shen, X.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 936 - 940
  • [29] Dynamic Threshold Cable-Stayed Bridge Health Monitoring System Based on Temperature Effect Correction
    Tan, Dongmei
    Guo, Tai
    Luo, Hao
    Ji, Baifeng
    Tao, Yu
    Li, An
    SENSORS, 2023, 23 (21)
  • [30] Fusion of monitoring data from cable-stayed bridge
    Bruschetta, F.
    Zonta, D.
    Cappello, C.
    Zandonini, R.
    Inaudi, D.
    Posenato, D.
    Pozzi, M.
    Wang, M. L.
    Glisic, B.
    Zhao, Y.
    2013 IEEE WORKSHOP ON ENVIRONMENTAL, ENERGY AND STRUCTURAL MONITORING SYSTEMS (EESMS 2013), 2013, : 51 - 56