摘要
Introduction: Dobutamine (DOB) stress in animal models of heart disease has been imaged so far using echocardiography and magnetic resonance imaging. The purpose of this study was to assess normal response to DOB stress in rats using anatomical and functional data using micro-computed tomography (CT). Methods: Ten normal adult male rats were first injected with a liposomal-based blood pool contrast agent and next infused with DOB via a tail vein catheter. Using prospective gating, 5 pairs of systole/diastole micro-CT images were acquired (a) pre-infusion baseline; (b) at heart rate plateau during infusion of 10 mu g/kg/min DOB; (c) at post-DOB infusion baseline; (d) at heart rate plateau during infusion of 30 mu g/kg/min DOB; and (e) after post-infusion return to baseline. Heart rate, peripheral and breathing distensions were monitored by oximetry. Micro-CT images with 88-mu m isotropic voxels were segmented to obtain cardiac function based on volumetric measurements of the left ventricle. Results: DOB stress increased heart rate and cardiac output with both doses. Ejection fraction increased above baseline by an average of 35.9% with the first DOB dose and 18.4% with the second dose. No change was observed in the relative peripheral arterial pressures associated with the significant increases in cardiac output. Discussion: Micro-CT proved to be a robust imaging method able to provide isotropic data on cardiac morphology and function. Micro-CT has the advantage of being faster and more cost-effective than MR and is able to provide higher accuracy than echocardiography. The impact of such an enabling technology can be enormous in evaluating cardiotoxic effects of various test drugs. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [21] Imaging Techniques for the Assessment of the Bone Osteoporosis-Induced Variations with Particular Focus on Micro-CT Potential
    Molino, Giulia
    Montalbano, Giorgia
    Pontremoli, Carlotta
    Fiorilli, Sonia
    Vitale-Brovarone, Chiara
    APPLIED SCIENCES-BASEL, 2020, 10 (24): : 1 - 27
  • [22] Quantitative Analysis of Micro-CT Imaging and Histopathological Signatures of Experimental Arthritis in Rats
    Silva, Matthew D.
    Savinainen, Anneli
    Kapadia, Rasesh
    Ruan, Jason
    Siebert, Elizabeth
    Avitahl, Nicole
    Mosher, Rebecca
    Anderson, Karen
    Jaffee, Bruce
    Schopf, Lisa
    Chandra, Sudeep
    MOLECULAR IMAGING, 2004, 3 (04): : 312 - 318
  • [23] Validation of Fluorescence Molecular Tomography/Micro-CT Multimodal Imaging In Vivo in Rats
    Vonwil, Daniel
    Christensen, Jon
    Fischer, Sascha
    Ronneberger, Olaf
    Shastri, V. Prasad
    MOLECULAR IMAGING AND BIOLOGY, 2014, 16 (03) : 350 - 361
  • [24] Validation of Fluorescence Molecular Tomography/Micro-CT Multimodal Imaging In Vivo in Rats
    Daniel Vonwil
    Jon Christensen
    Sascha Fischer
    Olaf Ronneberger
    V. Prasad Shastri
    Molecular Imaging and Biology, 2014, 16 : 350 - 361
  • [25] A micro-CT system for little animal imaging
    Zhong, AJ
    Ye, C
    Luo, QM
    PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 330 - 335
  • [26] Cryostatic micro-CT imaging of transient processes
    Jorgensen, SM
    Blank, B
    Ritman, EL
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 140 - 145
  • [27] Micro-CT imaging of Randall's plaques
    Williams, James C., Jr.
    Lingeman, James E.
    Coe, Fredric L.
    Worcester, Elaine M.
    Evan, Andrew P.
    UROLITHIASIS, 2015, 43 (01) : S13 - S17
  • [28] Micro-CT imaging of Randall’s plaques
    James C. Williams
    James E. Lingeman
    Fredric L. Coe
    Elaine M. Worcester
    Andrew P. Evan
    Urolithiasis, 2015, 43 : 13 - 17
  • [29] Advances in micro-CT imaging of small animals
    Clark, D. P.
    Badea, C. T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 175 - 192
  • [30] In Vivo Imaging of MSCT and Micro-CT: a Comparison
    Schwarz, M.
    Engelhorn, T.
    Eyupoglu, I. Y.
    Bruenner, H.
    Struffert, T.
    Kalender, W.
    Doerfler, A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (04): : 322 - 326