Quantitative Analysis of Micro-CT Imaging and Histopathological Signatures of Experimental Arthritis in Rats

被引:29
|
作者
Silva, Matthew D. [1 ]
Savinainen, Anneli [1 ]
Kapadia, Rasesh [2 ]
Ruan, Jason [1 ]
Siebert, Elizabeth [1 ]
Avitahl, Nicole [1 ]
Mosher, Rebecca [1 ]
Anderson, Karen [1 ]
Jaffee, Bruce [1 ]
Schopf, Lisa [1 ]
Chandra, Sudeep [1 ]
机构
[1] Millennium Pharmaceut Inc, Cambridge, MA 02139 USA
[2] Scanco USA Inc, Wayne, PA USA
来源
MOLECULAR IMAGING | 2004年 / 3卷 / 04期
关键词
Micro-CT; bone; adjuvant-induced arthritis; bone roughness; bone volume;
D O I
10.1162/1535350042973562
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Micro-computed tomographic (micro-CT) imaging provides a unique opportunity to capture 3-D architectural information in bone samples. In this study of pathological joint changes in a rat model of adjuvant-induced arthritis (AA), quantitative analysis of bone volume and roughness were performed by micro-CT imaging and compared with histopathology methods and paw swelling measurement. Micro-CT imaging of excised rat hind paws (n = 10) stored in formalin consisted of approximately 600 30-mu m slices acquired on a 512 x 512 image matrix with isotropic resolution. Following imaging, the joints were scored from H&E stained sections for cartilage/bone erosion, pannus development, inflammation, and synovial hyperplasia. From micro-CT images, quantitative analysis of absolute bone volumes and bone roughness was performed. Bone erosion in the rat AA model is substantial, leading to a significant decline in tarsal volume (27%). The result of the custom bone roughness measurement indicated a 55% increase in surface roughness. Histological and paw volume analyses also demonstrated severe arthritic disease as compared to controls. Statistical analyses indicate correlations among bone volume, roughness, histology, and paw volume. These data demonstrate that the destructive progression of disease in a rat AA model can be quantified using 3-D micro-CT image analysis, which allows assessment of arthritic disease status and efficacy of experimental therapeutic agents. Mol Imaging (2004) 3, 312-318.
引用
收藏
页码:312 / 318
页数:7
相关论文
共 50 条
  • [1] Micro-CT Analysis of Experimental Candida Osteoarthritis in Rats
    Takamasa Amanai
    Yasunori Nakamura
    Shigeji Aoki
    Izumi Mataga
    Mycopathologia, 2008, 166 : 133 - 141
  • [2] Micro-CT analysis of experimental Candida osteoarthritis in rats
    Amanai, Takamasa
    Nakamura, Yasunori
    Aoki, Shigeji
    Mataga, Izumi
    MYCOPATHOLOGIA, 2008, 166 (03) : 133 - 141
  • [3] Micro-CT imaging analysis for the effects of ibandronate and eldecalcitol on secondary osteoporosis and arthritis in adjuvant-induced arthritis rats
    Ono, Yuichi
    Miyakoshi, Naohisa
    Kasukawa, Yuji
    Imai, Yuuki
    Nagasawa, Hiroyuki
    Tsuchie, Hiroyuki
    Akagawa, Manabu
    Nagahata, Itsuki
    Yuasa, Yusuke
    Sato, Chiaki
    Kawatani, Masahito
    Shimada, Yoichi
    BIOMEDICAL RESEARCH-TOKYO, 2019, 40 (05): : 197 - 205
  • [4] Quantitative micro-CT
    Schladitz, K.
    JOURNAL OF MICROSCOPY, 2011, 243 (02) : 111 - 117
  • [5] Variation in segmentation of bone from micro-CT imaging: implications for quantitative morphometric analysis
    I. H. Parkinson
    A. Badiei
    N. L. Fazzalari
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 160 - 164
  • [6] Variation in segmentation of bone from micro-CT imaging: implications for quantitative morphometric analysis
    Parkinson, I. H.
    Badiei, A.
    Fazzalari, N. L.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (02) : 160 - 164
  • [7] Micro-CT imaging analysis for the effect of celecoxib, a cyclooxygenase-2 inhibitor, on inflammatory bone destruction in adjuvant arthritis rats
    Masahiro Noguchi
    Aishi Kimoto
    Masao Sasamata
    Keiji Miyata
    Journal of Bone and Mineral Metabolism, 2008, 26 : 461 - 468
  • [8] Micro-CT imaging analysis for the effect of celecoxib, a cyclooxygenase-2 inhibitor, on inflammatory bone destruction in adjuvant arthritis rats
    Noguchi, Masahiro
    Kimoto, Aishi
    Sasamata, Masao
    Miyata, Keiji
    JOURNAL OF BONE AND MINERAL METABOLISM, 2008, 26 (05) : 461 - 468
  • [9] Quantitative analysis of vascular parameters for micro-CT imaging of vascular networks with multi-resolution
    Fengjun Zhao
    Jimin Liang
    Xueli Chen
    Junting Liu
    Dongmei Chen
    Xiang Yang
    Jie Tian
    Medical & Biological Engineering & Computing, 2016, 54 : 511 - 524
  • [10] Quantitative analysis of vascular parameters for micro-CT imaging of vascular networks with multi-resolution
    Zhao, Fengjun
    Liang, Jimin
    Chen, Xueli
    Liu, Junting
    Chen, Dongmei
    Yang, Xiang
    Tian, Jie
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (2-3) : 511 - 524