Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats

被引:12
|
作者
Badea, Cristian T. [1 ]
Hedlund, Laurence W. [1 ]
Cook, James [1 ]
Berridge, Brian R. [2 ]
Johnson, G. Allan [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Dept Radiol, Durham, NC 27710 USA
[2] GlaxoSmithKline Safety Assessment, Res Triangle Pk, NC 27709 USA
关键词
Cardiac; Small animal imaging; Lung; Micro-CT; Stress; Dobutamine; COMPUTED-TOMOGRAPHY; CONTRAST AGENT; MOUSE HEART; MASS; RECONSTRUCTION; MODEL; MRI;
D O I
10.1016/j.vascn.2010.04.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Dobutamine (DOB) stress in animal models of heart disease has been imaged so far using echocardiography and magnetic resonance imaging. The purpose of this study was to assess normal response to DOB stress in rats using anatomical and functional data using micro-computed tomography (CT). Methods: Ten normal adult male rats were first injected with a liposomal-based blood pool contrast agent and next infused with DOB via a tail vein catheter. Using prospective gating, 5 pairs of systole/diastole micro-CT images were acquired (a) pre-infusion baseline; (b) at heart rate plateau during infusion of 10 mu g/kg/min DOB; (c) at post-DOB infusion baseline; (d) at heart rate plateau during infusion of 30 mu g/kg/min DOB; and (e) after post-infusion return to baseline. Heart rate, peripheral and breathing distensions were monitored by oximetry. Micro-CT images with 88-mu m isotropic voxels were segmented to obtain cardiac function based on volumetric measurements of the left ventricle. Results: DOB stress increased heart rate and cardiac output with both doses. Ejection fraction increased above baseline by an average of 35.9% with the first DOB dose and 18.4% with the second dose. No change was observed in the relative peripheral arterial pressures associated with the significant increases in cardiac output. Discussion: Micro-CT proved to be a robust imaging method able to provide isotropic data on cardiac morphology and function. Micro-CT has the advantage of being faster and more cost-effective than MR and is able to provide higher accuracy than echocardiography. The impact of such an enabling technology can be enormous in evaluating cardiotoxic effects of various test drugs. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [41] Micro-CT imaging analysis for the effects of ibandronate and eldecalcitol on secondary osteoporosis and arthritis in adjuvant-induced arthritis rats
    Ono, Yuichi
    Miyakoshi, Naohisa
    Kasukawa, Yuji
    Imai, Yuuki
    Nagasawa, Hiroyuki
    Tsuchie, Hiroyuki
    Akagawa, Manabu
    Nagahata, Itsuki
    Yuasa, Yusuke
    Sato, Chiaki
    Kawatani, Masahito
    Shimada, Yoichi
    BIOMEDICAL RESEARCH-TOKYO, 2019, 40 (05): : 197 - 205
  • [42] Dobutamine-induced Takotsubo syndrome during stress echocardiogram - An unusual but potentially severe association
    Mangolini, Vitor Iglesias
    Baron, Gabriel Bernardes
    Amaro, Guilherme
    Lipari, Layara
    Amstalden, Natalia
    Dantas, Rafael Tourinho
    Bastos, Pedro Augusto
    Andreucci Torres Lea, Tatiana de Carvalho
    Soeiro, Alexandre de Matos
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2020, 66 (06): : 724 - 727
  • [43] Multimodal Optical/micro-CT Imaging System for Intraoperative Breast Tumor Margin Assessment
    McClatchy, D.
    Rizzo, E.
    Wells, W.
    Paulsen, K.
    Pogue, B.
    MEDICAL PHYSICS, 2017, 44 (06) : 3019 - 3019
  • [44] Dobutamine-induced chest pain does not predict ischemic findings on myocardial perfusion imaging
    John H. Lee
    Mohammad Abuannadi
    Philip G. Jones
    Timothy Bateman
    Randall Thompson
    James H. O’Keefe
    Journal of Nuclear Cardiology, 2008, 15 : 526 - 529
  • [45] Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging
    Namati, Eman
    Thiesse, Jacqueline
    Sieren, Jessica C.
    Ross, Alan
    Hoffman, Eric A.
    McLennan, Geoffrey
    MEDICAL PHYSICS, 2010, 37 (09) : 4793 - 4805
  • [46] MEASUREMENT OF DOBUTAMINE-INDUCED CHANGES IN CARDIAC-FUNCTION USING A NOVEL DOPPLER TECHNIQUE
    ACTON, G
    BROOM, C
    HOWLAND, K
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1989, 28 (02) : P225 - P226
  • [47] Micro-CT Analysis of Experimental Candida Osteoarthritis in Rats
    Takamasa Amanai
    Yasunori Nakamura
    Shigeji Aoki
    Izumi Mataga
    Mycopathologia, 2008, 166 : 133 - 141
  • [48] Micro-CT analysis of experimental Candida osteoarthritis in rats
    Amanai, Takamasa
    Nakamura, Yasunori
    Aoki, Shigeji
    Mataga, Izumi
    MYCOPATHOLOGIA, 2008, 166 (03) : 133 - 141
  • [49] Micro-CT Imaging and Mechanical Properties of Ovine Ribs
    Thomas, Patricia K.
    Caffrey, Juliette
    Afetse, K. Eddie
    Habet, Nahir A.
    Ondar, Kyle
    Weaver, Caitlin M.
    Kleinberger, Michael
    Brown, Philip
    Gayzik, F. Scott
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (07) : 1513 - 1522
  • [50] The role of micro-CT in imaging breast cancer specimens
    Tiwari, Ankur
    DiCorpo, Daniel
    Hughes, Kevin
    Michaelson, James
    CANCER RESEARCH, 2020, 80 (04)