Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: Prospective comparison with 2D-TOF MR venography and digital subtraction angiography

被引:1
|
作者
Liang, LX [1 ]
Korogi, Y [1 ]
Sugahara, T [1 ]
Onomichi, M [1 ]
Shigematsu, Y [1 ]
Yang, DW [1 ]
Kitajima, M [1 ]
Hiai, Y [1 ]
Takahashi, M [1 ]
机构
[1] Kumamoto Univ, Sch Med, Dept Radiol, Kumamoto 8608556, Japan
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous how on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, digital subtraction angiography (DSA), and conventional spin-echo (SE) MR imaging for the assessment of normal and abnormal dural sinuses. METHODS: In a phantom study, a plastic tube with pulsating flow was used to simulate the intracranial dural sinus. With 3D MP-RAGE, a variety of flow velocities, contrast material concentrations, and angulations between the phantom how tube and the plane of acquisition were tested to measure their relationship to signal-to-noise ratio (SNR), In a clinical study, 35 patients, including 18 with suspected dural sinus thrombosis, were studied with both MR imaging and DSA. Receiver operating characteristic (ROC) analysis was performed in a blinded fashion using DSA as the reference standard. RESULTS: With the phantom, the SNR of flow increased with increasing contrast concentration, but was not affected by the angle between tbe tube and scan slab. There was no relationship between SNR and velocity when the contrast concentration was 1.0 mmol/L or greater. In the clinical study, dural sinus thrombosis as well as the normal anatomy of the dural sinuses were seen better with 3D contrast-enhanced MP-RAGE than with 2D-TOF MR venography. Three-dimensional contrast-enhanced MP-RAGE showed the highest diagnostic confidence on ROC curves in the diagnosis of thrombosis. CONCLUSION: Three-dimensional contrast-enhanced MP-RAGE is superior to 2D-TOF MR venography and conventional SE MR imaging in the depiction of normal venous structures and the diagnosis of dural sinus thrombosis, and is a potential alternative to DSA.
引用
收藏
页码:481 / 492
页数:12
相关论文
共 50 条
  • [41] Histopathologic correlation of small lymph node metastases of prostate carcinomas: Evaluation with a Gd-DTPA-enhanced optimized 3D MP-RAGE sequence
    Engelhard, K
    Hollenbach, HP
    Kiefer, B
    Riedl, C
    RADIOLOGY, 1996, 201 : 329 - 329
  • [42] Acceleration Apportionment: A Method of Improved 2D SENSE Acceleration Applied to 3D Contrast-Enhanced MR Angiography
    Weavers, Paul T.
    Borisch, Eric A.
    Johnson, Casey P.
    Riederer, Stephen J.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 672 - 680
  • [43] Vascular masking for improved unfolding in 2D SENSE-accelerated 3D contrast-enhanced MR angiography
    Stinson, Eric G.
    Borisch, Eric A.
    Johnson, Casey P.
    Trzasko, Joshua D.
    Young, Phillip M.
    Riederer, Stephen J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (05) : 1161 - 1170
  • [44] Value of 3D-TOF MR angiography and 4D-dynamic contrast-enhanced MRI in the assessment of spontaneous posterior cavernous sinus dural arteriovenous fistula
    Caparroz Neto, Francisco Bermal
    Abud, Lucas Giansante
    Gomes de Oliveira, Rafael Gouveia
    Abud, Daniel Giansante
    Cabete Fabio, Soraia Ramos
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2021, 79 (06) : 559 - 560
  • [45] Follow-up of intracranial aneurysms treated with detachable coils: Comparison of gadolinium-enhanced 3D time-of-flight MR angiography and digital subtraction angiography
    Boulin, A
    Pierot, L
    RADIOLOGY, 2001, 219 (01) : 108 - 113
  • [46] Preoperative evaluation of pancreatic carcinoma: The value of combined MR imaging, MR cholangiopancreatography, and contrast-enhanced dual phase 3D MR angiography
    Kim, AY
    Lee, M
    Kim, T
    Kim, P
    Ha, H
    RADIOLOGY, 2001, 221 : 252 - 252
  • [47] Quality-Evaluation Scheme for Cerebral Time-Resolved 3D Contrast-Enhanced MR Angiography Techniques
    Raoult, H.
    Ferre, J. -C.
    Morandi, X.
    Carsin-Nicol, B.
    Carsin, M.
    Cuggia, M.
    Law, M.
    Gauvrit, J. -Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (08) : 1480 - 1487
  • [48] Preoperative evaluation of venous systems with 3-dimensional contrast-enhanced magnetic resonance venography in brain tumors: comparison with time-of-flight magnetic resonance venography and digital subtraction angiography
    Lee, JM
    Jung, S
    Moon, KS
    Seo, JJ
    Kim, IY
    Jung, TY
    Lee, JK
    Kang, SS
    SURGICAL NEUROLOGY, 2005, 64 (02): : 128 - 134
  • [49] Follow-up of coiled cerebral aneurysms at 3T: Comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography
    Anzalone, N.
    Scomazzoni, F.
    Cirillo, M.
    Righi, C.
    Simionato, F.
    Cadioli, M.
    Iadanza, A.
    Kirchin, M. A.
    Scotti, G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (08) : 1530 - 1536
  • [50] High-resolution 3D non-contrast-enhanced, ECG-gated, multi-step MR angiography of the lower extremities: Comparison with contrast-enhanced MR angiography
    Oliver K. Mohrs
    Steffen E. Petersen
    Martin C. Heidt
    Thomas Schulze
    Peter Schmitt
    Sabine Bergemann
    Hans-Ulrich Kauczor
    European Radiology, 2011, 21 : 434 - 442