Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: Prospective comparison with 2D-TOF MR venography and digital subtraction angiography

被引:1
|
作者
Liang, LX [1 ]
Korogi, Y [1 ]
Sugahara, T [1 ]
Onomichi, M [1 ]
Shigematsu, Y [1 ]
Yang, DW [1 ]
Kitajima, M [1 ]
Hiai, Y [1 ]
Takahashi, M [1 ]
机构
[1] Kumamoto Univ, Sch Med, Dept Radiol, Kumamoto 8608556, Japan
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous how on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, digital subtraction angiography (DSA), and conventional spin-echo (SE) MR imaging for the assessment of normal and abnormal dural sinuses. METHODS: In a phantom study, a plastic tube with pulsating flow was used to simulate the intracranial dural sinus. With 3D MP-RAGE, a variety of flow velocities, contrast material concentrations, and angulations between the phantom how tube and the plane of acquisition were tested to measure their relationship to signal-to-noise ratio (SNR), In a clinical study, 35 patients, including 18 with suspected dural sinus thrombosis, were studied with both MR imaging and DSA. Receiver operating characteristic (ROC) analysis was performed in a blinded fashion using DSA as the reference standard. RESULTS: With the phantom, the SNR of flow increased with increasing contrast concentration, but was not affected by the angle between tbe tube and scan slab. There was no relationship between SNR and velocity when the contrast concentration was 1.0 mmol/L or greater. In the clinical study, dural sinus thrombosis as well as the normal anatomy of the dural sinuses were seen better with 3D contrast-enhanced MP-RAGE than with 2D-TOF MR venography. Three-dimensional contrast-enhanced MP-RAGE showed the highest diagnostic confidence on ROC curves in the diagnosis of thrombosis. CONCLUSION: Three-dimensional contrast-enhanced MP-RAGE is superior to 2D-TOF MR venography and conventional SE MR imaging in the depiction of normal venous structures and the diagnosis of dural sinus thrombosis, and is a potential alternative to DSA.
引用
收藏
页码:481 / 492
页数:12
相关论文
共 50 条
  • [31] Carotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T
    Platzek, Ivan
    Sieron, Dominik
    Wiggermann, Philipp
    Laniado, Michael
    RADIOLOGY RESEARCH AND PRACTICE, 2014, 2014
  • [32] Peripheral angiography in diabetics with critical ischemia: Can triggered 2D TOF or subtracted 3D gadolinium enhanced MR imaging angiography replace selective digital subtraction angiography?
    Brophy, DP
    Saouaf, R
    Hartnell, GG
    McEniff, NJ
    Wheeler, HG
    Edelman, RR
    RADIOLOGY, 1997, 205 : 1355 - 1355
  • [33] Diagnostic value of 3D contrast-enhanced magnetic resonance angiography in Takayasu’s arteritis—a comparative study with digital subtraction angiography
    Shobhit K. Garg
    Suyash Mohan
    Sunil Kumar
    European Radiology, 2011, 21 : 1658 - 1666
  • [34] Preoperative evaluation of the arterial and portal venous blood supply of the liver: Comparison of contrast-enhanced 3D MR angiography with DSA
    Kopka, L
    Vosshenrich, R
    Fischer, U
    Grabbe, EH
    RADIOLOGY, 1997, 205 : 451 - 451
  • [35] Comparison of 2D Digital Subtraction Angiography and 3D Rotational Angiography in the Evaluation of Dome-to-Neck Ratio
    Brinjikji, W.
    Cloft, H.
    Lanzino, G.
    Kallmes, D. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (04) : 831 - 834
  • [36] Comparison of native high-resolution 3D and contrast-enhanced MR angiography for assessing the thoracic aorta
    von Knobelsdorff-Brenkenhoff, Florian
    Gruettner, Henriette
    Trauzeddel, Ralf F.
    Greiser, Andreas
    Schulz-Menger, Jeanette
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (06) : 651 - 658
  • [37] Follow-up of intracranial aneurysms treated by flow diverter: comparison of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MR angiography (CE-MRA) sequences with digital subtraction angiography as the gold standard
    Attali, Jonathan
    Benaissa, Azzedine
    Soize, Sebastien
    Kadziolka, Krzysztof
    Portefaix, Christophe
    Pierot, Laurent
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (01) : 81 - 86
  • [38] Evaluation of peripheral artery occlusive disease by high-resolution contrast-enhanced 3D MR angiography
    Steffens, JC
    Link, J
    Fronius, M
    MuellerHuelsbeck, S
    Brinkmann, G
    Heller, M
    RADIOLOGY, 1997, 205 : 1357 - 1357
  • [39] PRELIMINARY-RESULTS OF MR-IMAGING IN LYMPH-NODE DETECTION OF PROSTATE CARCINOMA WITH A GADOLINIUM-ENHANCED 3D MP-RAGE SEQUENCE
    ENGELHARD, K
    HOLLENBACH, HP
    RADIOLOGY, 1995, 197 : 185 - 186
  • [40] Diagnostic value of 3D contrast-enhanced magnetic resonance angiography in Takayasu's arteritis-a comparative study with digital subtraction angiography
    Garg, Shobhit K.
    Mohan, Suyash
    Kumar, Sunil
    EUROPEAN RADIOLOGY, 2011, 21 (08) : 1658 - 1666