Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: Prospective comparison with 2D-TOF MR venography and digital subtraction angiography

被引:1
|
作者
Liang, LX [1 ]
Korogi, Y [1 ]
Sugahara, T [1 ]
Onomichi, M [1 ]
Shigematsu, Y [1 ]
Yang, DW [1 ]
Kitajima, M [1 ]
Hiai, Y [1 ]
Takahashi, M [1 ]
机构
[1] Kumamoto Univ, Sch Med, Dept Radiol, Kumamoto 8608556, Japan
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous how on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, digital subtraction angiography (DSA), and conventional spin-echo (SE) MR imaging for the assessment of normal and abnormal dural sinuses. METHODS: In a phantom study, a plastic tube with pulsating flow was used to simulate the intracranial dural sinus. With 3D MP-RAGE, a variety of flow velocities, contrast material concentrations, and angulations between the phantom how tube and the plane of acquisition were tested to measure their relationship to signal-to-noise ratio (SNR), In a clinical study, 35 patients, including 18 with suspected dural sinus thrombosis, were studied with both MR imaging and DSA. Receiver operating characteristic (ROC) analysis was performed in a blinded fashion using DSA as the reference standard. RESULTS: With the phantom, the SNR of flow increased with increasing contrast concentration, but was not affected by the angle between tbe tube and scan slab. There was no relationship between SNR and velocity when the contrast concentration was 1.0 mmol/L or greater. In the clinical study, dural sinus thrombosis as well as the normal anatomy of the dural sinuses were seen better with 3D contrast-enhanced MP-RAGE than with 2D-TOF MR venography. Three-dimensional contrast-enhanced MP-RAGE showed the highest diagnostic confidence on ROC curves in the diagnosis of thrombosis. CONCLUSION: Three-dimensional contrast-enhanced MP-RAGE is superior to 2D-TOF MR venography and conventional SE MR imaging in the depiction of normal venous structures and the diagnosis of dural sinus thrombosis, and is a potential alternative to DSA.
引用
收藏
页码:481 / 492
页数:12
相关论文
共 50 条
  • [21] Normal structures in the intracranial dural sinuses: Delineation with 3D contrast-enhanced magnetization prepared rapid acquisition gradient-echo imaging sequence
    Liang, LX
    Korogi, Y
    Sugahara, T
    Ikushima, I
    Shigematsu, Y
    Takahashi, M
    Provenzale, JM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (10) : 1739 - 1746
  • [22] Comparison Between Mr Angiography At 3t (3d Time-of-flight And Contrast-enhanced) With Flat Panel Digital Subtraction Angiography In The Assessment Of Embolized Brain Aneurysms
    Nakiri, Guilherme S.
    Pontes-Neto, Octavio M.
    Santos, Antonio C.
    Abud, Thiago G.
    Abud, Daniel G., Sr.
    STROKE, 2011, 42 (03) : E169 - E169
  • [23] Intracranial Arteriovenous Malformation: Comparison of Time-Resolved and High Spatial Resolution Contrast-Enhanced MR Angiography at 3 T With Digital Subtraction Angiography
    Srinivas, M. R.
    Singh, P.
    Gupta, V
    Khandelwal, N.
    Mathuriya, S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [24] Utility of contrast-enhanced 3D turbo-flash MR angiography in evaluating the intracranial venous system
    A. Haroun
    Neuroradiology, 2005, 47 : 322 - 327
  • [25] Contrast-enhanced intracranial 3D MR angiography (CE-MRA) in assessing arterial stenoses and aneurysms
    Gottschalk, S
    Gaebel, C
    Haendler, G
    Gellissen, J
    Missler, U
    Seidel, G
    Nowak, G
    Petersen, D
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06): : 704 - 713
  • [26] Utility of contrast-enhanced 3D turbo-flash MR angiography in evaluating the intracranial venous system
    Haroun, A
    NEURORADIOLOGY, 2005, 47 (05) : 322 - 327
  • [27] Cerebral arteriovenous malformations (AVMs): Morphologic evaluation by ultrashort 3D contrast-enhanced MR angiography
    Essig, M
    Schoenberg, SO
    Knopp, MV
    Debus, J
    Lohr, F
    VanKaick, G
    RADIOLOGY, 1997, 205 : 1136 - 1136
  • [28] Contrast-enhanced 3D MR DSA of the carotid artery bifurcation: Preliminary study of comparison with unenhanced 2D and 3D time-of-flight MR angiography
    Willig, DS
    Turski, PA
    Frayne, R
    Graves, VB
    Korosec, FR
    Swan, JS
    Mistretta, CA
    Grist, TM
    RADIOLOGY, 1998, 208 (02) : 447 - 451
  • [29] Magnitude subtraction vs. complex subtraction in dynamic contrast-enhanced 3D-MR angiography: Basic experiments and clinical evaluation
    Naganawa, S
    Ito, T
    Iwayama, E
    Fukatsu, H
    Ishiguchi, T
    Ishigaki, T
    Ichinose, N
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (05): : 813 - 820
  • [30] Optimization of contrast-enhanced MR angiography of the hands with a timing bolus and elliptically reordered 3D pulse sequence
    Winterer, JT
    Scheffler, K
    Paul, G
    Hauer, M
    Schäfer, O
    Altehoefer, C
    Laubenberger, J
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (06) : 903 - 908