Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: Prospective comparison with 2D-TOF MR venography and digital subtraction angiography

被引:1
|
作者
Liang, LX [1 ]
Korogi, Y [1 ]
Sugahara, T [1 ]
Onomichi, M [1 ]
Shigematsu, Y [1 ]
Yang, DW [1 ]
Kitajima, M [1 ]
Hiai, Y [1 ]
Takahashi, M [1 ]
机构
[1] Kumamoto Univ, Sch Med, Dept Radiol, Kumamoto 8608556, Japan
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous how on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, digital subtraction angiography (DSA), and conventional spin-echo (SE) MR imaging for the assessment of normal and abnormal dural sinuses. METHODS: In a phantom study, a plastic tube with pulsating flow was used to simulate the intracranial dural sinus. With 3D MP-RAGE, a variety of flow velocities, contrast material concentrations, and angulations between the phantom how tube and the plane of acquisition were tested to measure their relationship to signal-to-noise ratio (SNR), In a clinical study, 35 patients, including 18 with suspected dural sinus thrombosis, were studied with both MR imaging and DSA. Receiver operating characteristic (ROC) analysis was performed in a blinded fashion using DSA as the reference standard. RESULTS: With the phantom, the SNR of flow increased with increasing contrast concentration, but was not affected by the angle between tbe tube and scan slab. There was no relationship between SNR and velocity when the contrast concentration was 1.0 mmol/L or greater. In the clinical study, dural sinus thrombosis as well as the normal anatomy of the dural sinuses were seen better with 3D contrast-enhanced MP-RAGE than with 2D-TOF MR venography. Three-dimensional contrast-enhanced MP-RAGE showed the highest diagnostic confidence on ROC curves in the diagnosis of thrombosis. CONCLUSION: Three-dimensional contrast-enhanced MP-RAGE is superior to 2D-TOF MR venography and conventional SE MR imaging in the depiction of normal venous structures and the diagnosis of dural sinus thrombosis, and is a potential alternative to DSA.
引用
下载
收藏
页码:481 / 492
页数:12
相关论文
共 50 条
  • [1] Contrast-enhanced 3D MR angiography of the carotid artery:: Comparison with conventional digital subtraction angiography
    Remonda, L
    Senn, P
    Barth, A
    Arnold, M
    Lövblad, KO
    Schroth, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (02) : 213 - 219
  • [2] Evaluation of abdominal aortic aneurysm for stent-grafting: Contrast-enhanced 3D-TOF MR angiography versus 3D CT angiography versus digital subtraction angiography
    Thurnher, SA
    Dorffner, R
    Thurnher, MM
    Kretschmer, G
    Polterauer, P
    Lammer, J
    RADIOLOGY, 1997, 205 : 1564 - 1564
  • [3] Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms
    Sugahara, T
    Korogi, Y
    Nakashima, K
    Hamatake, S
    Honda, S
    Takahashi, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (09) : 1545 - 1552
  • [4] Intracranial dural arteriovenous fistulas: Evaluation with combined 3D time-of-flight MR angiography and MR digital subtraction angiography
    Noguchi, K
    Melhem, ER
    Kanazawa, T
    Kubo, M
    Kuwayama, N
    Seto, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (01) : 183 - 190
  • [5] Arachnoid granulations in the cerebral dural sinuses as demonstrated by contrast-enhanced 3D magnetic resonance venography
    Azmi A. Haroun
    Waleed S. Mahafza
    Mahasen S. Al Najar
    Surgical and Radiologic Anatomy, 2007, 29 : 323 - 328
  • [6] Arachnoid granulations in the cerebral dural sinuses as demonstrated by contrast-enhanced 3D magnetic resonance venography
    Haroun, Azmi A.
    Mahafza, Waleed S.
    Al Najar, Mahasen S.
    SURGICAL AND RADIOLOGIC ANATOMY, 2007, 29 (04) : 323 - 328
  • [7] Usefulness of contrast-enhanced 3D MR angiography and contrast-enhanced 3D T1 sequence for detecting intracranial infectious aneurysms in infectious endocarditis
    Boukobza, Monique
    Ilic-Habensus, Emila
    Duval, Xavier
    Laissy, Jean-Pierre
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 144
  • [8] Evaluation of Intracranial Dural Arteriovenous Fistulas: Comparison of Unenhanced 3T 3D Time-of-flight MR Angiography with Digital Subtraction Angiography
    Azuma, Minako
    Hirai, Toshinori
    Shigematsu, Yoshinori
    Kitajima, Mika
    Kai, Yutaka
    Yano, Shigetoshi
    Nakamura, Hideo
    Makino, Keishi
    Iryo, Yasuhiko
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2015, 14 (04) : 285 - 293
  • [9] Comparison of high-resolution contrast-enhanced 3D MRA with digital subtraction angiography in the evaluation of hepatic arterial anatomy
    Matoba, M
    Tonami, H
    Kuginuki, M
    Yokota, H
    Takashima, S
    Yamamoto, I
    CLINICAL RADIOLOGY, 2003, 58 (06) : 463 - 468
  • [10] Contrast-enhanced 3D MR angiography of moyamoya disease: Comparison with conventional 3D time-of-flight MR angiography
    Yoon, H
    Shin, H
    Na, D
    Cho, Y
    Han, BK
    RADIOLOGY, 2000, 217 : 429 - 429