Safety Analysis of All-Inside Arthroscopic Repair of Peripheral Triangular Fibrocartilage Complex

被引:15
|
作者
Waterman, Scott M. [1 ]
Slade, Dirk [2 ]
Masini, Brendan D. [3 ]
Owens, Brett D. [4 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Bethesda, MD 20889 USA
[2] William Beaumont Army Med Ctr, El Paso, TX 79920 USA
[3] San Antonio Mil Med Ctr, San Antonio, TX USA
[4] Keller Army Community Hosp, West Point, NY USA
关键词
DORSAL SENSORY BRANCH; PARTIAL EXCISION; ARTICULAR DISK; ISOLATED TEARS; ULNAR NERVE; WRIST; MANAGEMENT; ANATOMY; INJURY;
D O I
10.1016/j.arthro.2010.02.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine whether an all-inside peripheral triangular fibrocartilage complex (TFCC) repair using the FasT-Fix device (Smith & Nephew Endoscopy, Andover, MA) is safe by measuring the proximity of the anchors to ulnar-sided anatomic structures. Methods: Eleven fresh-frozen cadaveric wrists were thawed and placed in traction. Under direct arthroscopic visualization, an all-inside arthroscopic peripheral TFCC repair was completed by placing a single FasT-Fix device in a vertical mattress fashion. The wrists were then dissected to visualize the 2 anchors. The distance between these anchors and the flexor carpi ulnaris (FCU), extensor carpi ulnaris (ECU), and dorsal branch of the ulnar sensory nerve (DBUN) were measured with digital calipers and recorded. Results: The peripheral anchor averaged 4.2 mm (range, 0 to 14 mm) from the ECU tendon, 3.8 mm (range, 0 to 9 mm) from the DBUN, and 8.3 mm (range, 1 to 15 mm) from the FCU tendon. The central anchor averaged 9.6 mm (range, 2 to 15 mm) from the ECU tendon, 6.8 mm (range, 1 to 13 mm) from the DBUN, and 7.6 mm (range, 1 to 13 mm) from the FCU tendon. Conclusions: This study exposes some safety concerns with the all-inside peripheral TFCC repair using the FasT-Fix device, which was found to reside in close proximity to the ECU, FCU, and DBUN. In multiple wrists the anchors were noted to underlie the anatomic structure that we measured, making it possible to pierce these structures with the needle before deployment of the anchor. Clinical Relevance: Though technically feasible, all-inside arthroscopic repair of the peripheral TFCC risks injury to the ulnar-sided anatomy.
引用
收藏
页码:1474 / 1477
页数:4
相关论文
共 50 条
  • [31] Arthroscopic Management of Traumatic Peripheral Triangular Fibrocartilage Complex Tears
    Strauss, Nicole L.
    Goldfarb, Charles A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (01): : 136 - 138
  • [32] Arthroscopic transosseous foveal footprint repair of the triangular fibrocartilage complex
    Yang, Chen-Yuan
    Chen, Wei-Jen
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (05) : 486 - 494
  • [33] ARTHROSCOPIC DIRECT REPAIR FOR RADIAL TEAR OF THE TRIANGULAR FIBROCARTILAGE COMPLEX
    Cho, Chul-Hyun
    Lee, Young-Kuk
    Sin, Hong-Kwan
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2012, 17 (03): : 429 - 432
  • [34] All-Arthroscopic Triangular Fibrocartilage Complex Repair: Safety and Biomechanical Comparison With a Traditional Outside-in Technique in Cadavers
    Yao, Jeffrey
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (04): : 671 - 676
  • [35] Arthroscopic Transosseous Repair for both Proximal and Distal Components of Peripheral Triangular Fibrocartilage Complex Tear
    Ji Hun Park
    Jong Woong Park
    Indian Journal of Orthopaedics, 2018, 52 : 596 - 601
  • [36] Arthroscopic Transosseous Repair for both Proximal and Distal Components of Peripheral Triangular Fibrocartilage Complex Tear
    Park, Ji Hun
    Park, Jong Woong
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (06) : 596 - 601
  • [37] Comparative outcomes between all-inside arthroscopic suture anchor technique versus arthroscopic transosseous suture technique in patients with triangular fibrocartilage complex tear: a retrospective comparative study
    Hung, Chia-Hung
    Kuo, Yu-Feng
    Chen, Yu-Jen
    Yeh, Ping-Chun
    Cho, Hsiao-Yun
    Chen, Yeong-Jang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [38] Comparative outcomes between all-inside arthroscopic suture anchor technique versus arthroscopic transosseous suture technique in patients with triangular fibrocartilage complex tear: a retrospective comparative study
    Chia-Hung Hung
    Yu-Feng Kuo
    Yu-Jen Chen
    Ping-Chun Yeh
    Hsiao-Yun Cho
    Yeong-Jang Chen
    Journal of Orthopaedic Surgery and Research, 16
  • [39] A Novel All-Inside Knotless Arthroscopic Deltoid Ligament Repair
    Tansey, Patrick J.
    Castillo, Isaac
    Panchbhavi, Vinod K.
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2024, 23 (01): : 1 - 5
  • [40] Arthroscopic repair of radial-sided triangular fibrocartilage complex tears
    Sagerman, SD
    Short, W
    ARTHROSCOPY, 1996, 12 (03): : 339 - 342